Advertisement

Quick Links

Operation Manual for USB Autoscope IV
Please read this manual thoroughly before attempting to operate the device.
Contents
1. Purpose.......................................................................................................................................2
2. Technical characteristics of the USB Autoscope IV................................................................2
2.1 General...................................................................................................................................2
2.2 Analog oscilloscope mode.....................................................................................................3
2.3 Software.................................................................................................................................3
2.4 Parameters of the USB port's galvanic isolation....................................................................4
2.5 Front panel elements..............................................................................................................5
2.6 Back panel elements..............................................................................................................6
2.7 Power supply cable................................................................................................................7
2.8 Universal cable......................................................................................................................7
3. Preparing the computer for use with the USB Autoscope IV................................................8
3.1 Minimum Laptop or PC requirements...................................................................................8
3.2 Installation of the USB Oscilloscope program and utilities..................................................9
3.3 Installation of the device drivers..........................................................................................13
4. Preparing the device for use....................................................................................................14
5. USB Autoscope IV kit description..........................................................................................16
6. Manufacturer limited warranty.............................................................................................20
7. Troubleshooting........................................................................................................................20
7.1 The device does not turn on.................................................................................................20
7.2 "USB transfer error"............................................................................................................21
http://usbautoscope.eu/
USB Autoscope IV - Operation Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the USB Autoscope IV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Autoscope Technology USB Autoscope IV

  • Page 1: Table Of Contents

    2.6 Back panel elements......................6 2.7 Power supply cable........................7 2.8 Universal cable........................7 3. Preparing the computer for use with the USB Autoscope IV..........8 3.1 Minimum Laptop or PC requirements...................8 3.2 Installation of the USB Oscilloscope program and utilities..........9 3.3 Installation of the device drivers..................13 4.
  • Page 2: Purpose

    USB Autoscope IV – Operation Manual 1. Purpose The USB Autoscope IV is used for troubleshooting of various electronic vehicle systems, such as ignition and timing system. The USB Autoscope IV is also very useful for engine mechanical diagnostics. The device is universal in nature and not tied to any particular vehicle system or brand.
  • Page 3: Analog Oscilloscope Mode

    USB Autoscope IV – Operation Manual 2.2 Analog oscilloscope mode  Number of analog inputs – 8  Voltage range (switchable, two ranges) analog inputs 1…4 – ±6 / 30 V analog inputs 5, 6 – ±60 / 300 V analog inputs 7, 8 –...
  • Page 4: Parameters Of The Usb Port's Galvanic Isolation

    FAT32 – 4 GB NTFS – 16 TB 2.4 Parameters of the USB port's galvanic isolation USB Autoscope IV has galvanic isolation of the USB port (device inputs ground <> PC ground)  Galvanic isolation resistance – not less than 20 GΩ...
  • Page 5: Front Panel Elements

    USB Autoscope IV – Operation Manual 2.5 Front panel elements Front panel of the USB Autoscope IV. 1…4 Connections for analog inputs 1…4. Input voltage range ± 6 / 30 V. 5…6 Connections for analog inputs 5…6. Input voltage range ± 60 / 300 V.
  • Page 6: Back Panel Elements

    USB Autoscope IV – Operation Manual 2.6 Back panel elements Back panel of the USB Autoscope IV. 1 12 V connection. Used for powering certain transducers that are connected to the inputs. Connects to the diagnosed vehicle battery through the power supply cable.
  • Page 7: Power Supply Cable

    4 Power ground 2.8 Universal cable Universal cables are used for connection to the inputs 1…6 of the USB Autoscope IV measuring adapters and / or transducers. In case of breakage of the cable, it can be repaired or manufactured according to the diagram below.
  • Page 8: Preparing The Computer For Use With The Usb Autoscope Iv

    USB Autoscope IV – Operation Manual 3. Preparing the computer for use with the USB Autoscope IV 3.1 Minimum Laptop or PC requirements  Processor – Pentium IV 2 GHz  RAM (random-access memory) – 1 GB  Hard disk drive –...
  • Page 9: Installation Of The Usb Oscilloscope Program And Utilities

    USB Autoscope IV – Operation Manual 3.2 Installation of the USB Oscilloscope program and utilities  Insert the installation CD disc in the optical disk drive of the computer.  If the notification "Tap to choose what happens with this disk" appears, left-click the message screen.
  • Page 10 USB Autoscope IV – Operation Manual  If a pop up about unknown publisher of "setup.exe" appears, click "Yes".  You may have to wait while the installer verifies.  In the window "Installer Language", change the installation language if desired.
  • Page 11 USB Autoscope IV – Operation Manual  In window "Windows Security" activate option "Always trust software from…" then press button "Install".  If the message "Windows can't verify the publisher of this driver software" appears, choose the option "Install this driver software anyway".
  • Page 12 USB Autoscope IV – Operation Manual  Press the "Finish" button. Now the USB Oscilloscope software is installed completely and drivers are presetting. http://usbautoscope.eu/...
  • Page 13: Installation Of The Device Drivers

    USB Autoscope IV – Operation Manual 3.3 Installation of the device drivers Connect the device to USB 2.0 480 Mbit/s (HI-SPEED) port of the laptop or PC only after installation of USB Oscilloscope software.  Right after connection of the device to a USB 2.0 480 Mbit/s (HI- SPEED) port the installation of drivers will start automatically.
  • Page 14: Preparing The Device For Use

     To provide power for the transducers connected to the inputs of the USB Autoscope IV, the red alligator clip of the power supply cable must be connected to the positive terminal of the vehicle battery.
  • Page 15 USB Autoscope IV – Operation Manual  To improve the usability of the device it is recommended to use the holder for USB Autoscope IV. The device holder comes unassembled. USB Autoscope IV holder assembly instructions. USB Autoscope IV holder full kit.
  • Page 16: Usb Autoscope Iv Kit Description

    USB Autoscope IV – Operation Manual 5. USB Autoscope IV kit description Name Appearance USB Autoscope IV, USB 2.0 A/B interface cable, USB cable hanger, power supply cable, CD with software http://usbautoscope.eu/...
  • Page 17 USB Autoscope IV – Operation Manual Device holder Universal cable, 4 pcs Measuring adapter, 4 pcs Needle probe, 4 pcs Insulation piercing probe, 2 pcs http://usbautoscope.eu/...
  • Page 18 USB Autoscope IV – Operation Manual Small alligator clip, 2 pcs Probe extension, 4 pcs Px35 in cylinder pressure transducer PxLonger deep well adapter for high pressure (in cylinder) transducer Spark Gap high voltage spark gap tester Dx vacuum transducer 4 Starting from 01.06.2014 instead of Px (-0.9…+6 Bar) the transducer Px35 (-0.95…+35 Bar) is supplied.
  • Page 19 USB Autoscope IV – Operation Manual Sync synchronization transducer DIS Cx 6 capacitive probes Cx-M universal capacitive probe http://usbautoscope.eu/...
  • Page 20: Manufacturer Limited Warranty

    USB Autoscope IV during their warranty period. Warranty period for the main unit USB Autoscope IV is 24 months from the date of sale, for transducers Px and Dx – 12 months. During the warranty period, the manufacturer will at their discretion, replace or repair components that failed due to a manufacturing defect or during normal use.
  • Page 21: Usb Transfer Error

    USB Autoscope IV – Operation Manual 7.2 "USB transfer error" If in the process of working with the device in the USB Oscilloscope window the message USB transfer error message appears, it indicates distortion and/or damage to the data that are sent via the USB interface.