Page 1
subzero.com 800.222.7820 V Series Cooktop Ventilation Service Manual General Information Installation Information Component Access & Removal Troubleshooting Guide Technical Data Wiring Diagrams...
V-Series Cooktop Hoods General Information V-Series Cooktop Hoods GENERAL INFORMATION The V-Series Cooktop Hood allows for elimination of fumes and cooking odors from the kitchen through use of dedi- cated exhaust piping and blower motor. This Wolf Appliance Service Manual has been compiled with the latest serv- ice information from Faber S.p.A.
V-Series Cooktop Hoods General Information V-Series Cooktop Hoods WARRANTY INFORMATION This page contains a summary of the Warranty supplied with every Domestic Wolf V-Series Cooktop Hood. NOTE: “ICB” warranties vary by Country and Distributor. Contact selling Distributor for warranty coverage. 2 &...
Page 4
General Information V-Series Cooktop Hoods V-Series Cooktop Hoods TO PROTECT FINISH, WASH WITH MILD SOAP OR DETERGENT ONLY. TO PROTECT FINISH, WASH WITH MILD SOAP OR DETERGENT ONLY. MODEL: VW36S Serial: 15508176 5610315 120 Vac 60 Hz 2x1 W LED LAMPS THERMALLY PROTECTED Wolf Appliance, Inc Fitchburg, WI 53719...
V-Series Cooktop Hoods General Information V-Series Cooktop Hoods Model Number Key Model: ICB V W 36 G International Product Type Size Style Product V-Series Hoods Type Wall Hood Island Hood Size 30,” 36,” 42,” and 45.” Style Glass Stainless Steal Black #825309 - Revision A - August, 2014...
V-Series Cooktop Hoods V-Series Cooktop Hoods INSTALLATION INFORMATION This section of the manual covers some of the installation issues that a service technician may need to know when servicing a Wolf V-Series Cooktop Hood. All dimensions are in inches. Maximum of three 90 degree elbows. Hood should not be installed on GFI receptacle.
V-Series Cooktop Hoods V-Series Cooktop Hoods Installation Requirements Hood Placement: Both the Island Hood and Wall Hood should be installed so that the bottom of the hood is 30” to 36” Hood above countertop. (See Figure 1) • Installing hood at less then 30” can damage hood Touch Control, LED Assemblies, or wiring.
Page 13
V-Series Cooktop Hoods V-Series Cooktop Hoods Installation Requirements Ducting: 1’ of 6” Ducting = 4’ of 6” (inch) round, rigid metal duct is recommended for Equivalent Ducting Length V- Series cooktop ventilation. Wall Hoods and Island Hoods include a Backdraft Damper.
Page 14
V-Series Cooktop Hoods V-Series Cooktop Hoods Wall Hood Mounting CEILING If an Internal Blower is being installed, install Internal 3 /4 " Blower prior to mounting the Hood. (19) 1. Mark center line of hood installation. Using the information in Figure 5 and the Chart below, mark 1 /16 hole locations for mounting brackets.
Page 15
Installation Information V-Series Cooktop Hoods V-Series Cooktop Hoods Island Hood Mounting Electrical Location Island Hoods have a Support Frame that is adjustable in height. The Support Frame is attached to ceiling, the Upper and Lower Chimney is attached, then Hood Body.
Component Access V-Series Cooktop Hood V-Series Cooktop Hood COMPONENT ACCESS AND REMOVAL This section explains how to access and remove components from a Wolf V-Series Hood. An attempt has been made to arrange these procedures in such a way as to simulate which components would need to be removed first in order to gain access to the other components.
Page 17
Component Access V-Series Cooktop Hood V-Series Cooktop Hood Filter Covers - Black Hoods Filters Black hoods have a Filter Cover. Filter Cover has a pin All V-Series Hoods have aluminum mesh filters. Glass that snaps into a receptacle on hood side. Pull on Filter and Stainless Steel models are same filter.
Page 18
Component Access V-Series Cooktop Hood V-Series Cooktop Hood LED Light Assembly Internal Blower Removal Hood lights are LED fixtures that must be replaced as The 600 cfm Internal Blower is mounted in Easy Cube assemblies. Lights are 12 VDC. portion of hood. Once Filter Covers (Black Hoods) and Filters are removed Internal Blower can be extracted.
Page 19
Component Access V-Series Cooktop Hood V-Series Cooktop Hood Touch Control Assembly - continued Power Board Assembly Removal To Remove Touch Control Assembly - Glass and The Power Board Assembly is located in a black case Stainless Steel Hoods: attached by two screws to front of Easy Cube. 1.
Troubleshooting V-Series Cooktop Hoods V-Series Cooktop Hoods TROUBLESHOOTING This section explains how to troubleshoot various components in Wolf V-Series Cooktop Hood. An attempt has been made to arrange these procedures in such a way as to trace the issue from component to component.
V-Series Cooktop Hoods Troubleshooting V-Series Cooktop Hoods Troubleshooting and Test Procedures Test Procedures Troubleshooting table ..........4-3 Test Procedures ............4-7 Hood Lights and Blower do not energize ..... 4-3 Testing Line Voltage at J-Box ....... 4-7 Blower Motor Runs only at High Speed ....4-4 Testing Line Voltage at Power Cable ....
Page 22
Troubleshooting V-Series Cooktop Hoods V-Series Cooktop Hoods RESOLUTION MANUAL PAGE SYMPTOM DIAGNOSTIC TEST Hood Lights and Blower do With Blower and Lights If Ribbon Cable is seat- Section 3, Page 4. not energize - continued. energized: ed correctly at all points, Section 3, Page 5.
Page 23
V-Series Cooktop Hoods Troubleshooting V-Series Cooktop Hoods DIAGNOSTIC TEST SYMPTOM RESOLUTION MANUAL PAGE Hood Lights do not work - Remove connector If Blower Motor is work- Section 3, Page 4. continued. LUX1 from Power Board ing, replace Power Test Procedure #6. and check for 115 VAC Board.
Page 24
Troubleshooting V-Series Cooktop Hoods V-Series Cooktop Hoods On motor side of termi- If reading Open between Installation Guide. Check for External/Inline Blower Motor. nal block disconnect Blower wires, or Test Procedure 14. External/Inline Blower Continuity from either Note: Perform “Blower Motor wires: Blower Wire to Ground: Motor does not run at any...
V-Series Cooktop Hoods Troubleshooting V-Series Cooktop Hoods Test Procedures 1. Testing Line Voltage at J-Box. 3. Testing Line Voltage at 3 Pin Connector in J-Box is mounted to the Support Frame on Island Electrical Box - continued Hoods and is mounted by Installer on wall behind Disconnect 3 Pin Connector and test on Power Upper Chimney on Wall Hoods.
Page 26
Troubleshooting V-Series Cooktop Hoods V-Series Cooktop Hoods 5. Testing Line Voltage to Transformer and Blower 7. Testing 12 VDC from Transformer Secondary. Motor. Wires in sheath are 12 VDC to LED Assemblies. Perform both of these tests with the Blower Motor The three pin connector is the Lighting Command and Lights Energized.
Page 27
V-Series Cooktop Hoods Troubleshooting V-Series Cooktop Hoods 9. Testing Lighting Voltage at Light Support a. Disconnect two pin Lighting Harness from LED Assembly connection. (See Figure 4-9). Internal Blower b. Measure voltage between pins of connector on Cable Connection Easy Cube side of connection. Measure volt- age at each Lighting Harness connection.
Technical Data V-Series Cooktop Hoods V-Series Cooktop Hoods Technical Data This Technical Data Section has been compiled with the latest information from Faber S.p.A. Company. 600 cfm Internal Blower 414 WATTS 115 VAC 3.6 AMPS Note: All measurements in Watts, Voltage, or amps are approximate. Actual readings can very plus or minus 10 percent.
Wiring Diagrams V-Series Cooktop Hoods V-Series Cooktop Hoods Basic Wiring 115 VAC comes in through the junction box then plugs into the Electrical Box. It is wired to the Power Board with a three wire harness. From the Power Board 115 VAC is sent back to the Electrical Box to the Terminal Block where the Internal, Remote or Inline Blower is connected.
V-Series Cooktop Hoods Wiring Diagrams V-Series Cooktop Hoods 3 Pin Connector in Electrical J-Box Electrical Power Connector White Cable Black 7 Pin Connector Brown Green to Power Blue Board Ground Yellow-Green Blower Terminal Block Electrical Box Electrical Supply to Hood #825309 - Revision A - August, 2014...
Page 31
Wiring Diagrams V-Series Cooktop Hoods V-Series Cooktop Hoods Electrical Box J-Box Electrical Connector Power Cable Brown Blue Ground Green Black White Remote Blue Blower Brown Internal Blower Internal Blower Harness 115 VAC is provided to terminals #1 and #2. Connect Blower Black wire to terminal A and White wire to terminal B.
Page 32
V-Series Cooktop Hoods Wiring Diagrams V-Series Cooktop Hoods Touch Control (in Hood Body) Ferromagnetic Device Ribbon Cable (From Hood Body connects in Easy Cube) Ribbon Cable (Passes through Easy Cube) Power Board Power Board and Touch Control #825309 - Revision A - August, 2014...
Page 33
Wiring Diagrams V-Series Cooktop Hoods V-Series Cooktop Hoods Additional LED Assemblies in Island Hoods LED Assembly with Two Pin Connector behind Light Support Light Control Circuit - 12 VDC Transformer 115 VAC 12 VDC from to LED Power Board Assembly Connector from Electrical Box Hood Body.
Page 34
V-Series Cooktop Hoods Wiring Diagrams V-Series Cooktop Hoods Additional LED Assemblies in Island Hoods Touch Control Ferromagnetic Device LED Assemblies Light Control Circuit Transformer 12 VDC to LED Assemblies Ribbon Cable J-Box 3 Pin Connector Electrical Electrical Box Power Connector Cable Ground Blower...
Need help?
Do you have a question about the Wolf V Series and is the answer not in the manual?
Questions and answers