Enter Enter System Information Language Set All default *USA SW Version Spanish Interface Selection Germany Italian *Keyboard French Japan RS-232 Keyboard Wedge function Keyboard Terminal Type Function Key Emulation *PC/AT/,PS/2 *OFF IBM PS/2 30-80 KB Emulation(For NB) PS/2 25,30 IBM XT *OFF ALT Mode IBM 5550...
Enter Enter RS-232 Parameters BAUD Rate Parity 1200 *None 2400 Even 4800 Space *9600 19200 Mark RS-232 Function Installation 38400 Data Bits Inter-character Delay (Default:00) Appendix A (00H-64H) Inter-message Delay (Default:00) Delay time=set up da-ta*1(ms) Stop Bits Appendix A (00H-0AH) Handshaking Protocol Delay (Default :...
Enter Enter Handshaking Protocol Scan Mode Tigger On/Off *None Continuous/Tigger Off ACK/NAK Continuous/LED always On RTS/CTS Xon/Xoff Flash On *Tigger On/Good read off Testing Continuous/ Timeout Off Continuous/No Tigger...
Enter Enter Buzzer set-up Character Installation You can pitch the buzzer tone and adjust the buzzer time The preamble and postamble character: You can put 10 ASCII Besides, you can the voice of boot and decoding at most in front of the barcode data. When the installation is “0”...
Page 8
Enter Enter Scan the barcode of the “Start Configuration” and “G1 1. Scan the barcode of the “Start Configuration” and “G1 Insert Character”. character insertion position” Check the ASCII table to get the ASCII code of the first and 2. Check the ASCII table to get the corresponding ASCII code of the insertion position.
Enter Enter Other Installation BAR-CODE INSTALLATION Scanning Verify UPC-A Reading *Single Double Bar / Space Setting Code ID (Default:F) *Bar = High 20H-7EH *Bar = Low UPC-A convert to EAN-13 Laser Data Speed Up *Off Transmit Check Character Truncate Leading Zero *Off...
Page 10
Enter Enter UPC-E Truncate Leading Digit (Default:00) Reading 00H-0DH Truncate Last Digit (Default:00) 00H-0DH Code ID (Default:G) Select Insertion (Default:00) 20H-7EH 00H-02H UPC-E convert to UPC-A Add-On 2/5 2 digit *Off 5 digit Transmit Check Character 2 or 5 digit *None Truncate Leading Zero...
Page 11
Enter Enter EAN-13 Truncate Leading Digit (Default:00) Reading 00H-08H Truncate Last Digit (Default:00) 00H-08H Code ID (Default:H) Select Insertion (Default:00) 20H-7EH 00H-02H Transmit Check Character Add-On 2/5 2 digit 5 digit Truncate Leading Digit (Default:00) 2 or 5 digit 00H-0DH Truncate Last Digit (Default:00) *None 00H-0DH...
Page 12
Enter Enter EAN-8 Add-On 2/5 Reading 2 digit 5 digit Code ID (Default:I) 2 or 5 digit 20H-7EH *None Transmit Check Character ISBN/ISSN Convert *Off Truncate Leading Digit (Default:00) 00H-08H Truncate Last Digit (Default:00) 00H-08H Select Insertion (Default:00) 00H-02H...
Page 13
Enter Enter Code-39 Add-On 2/5 Reading 2 digit 5 digit Code ID (Default:J) 2 or 5 digit 20H-7EH *None Verification *Off Transmit Check Character Checksum *Off...
Enter Enter Codabar Min. Length (Default:00) Reading 00H-32H Max. Length (Default:32H) 00H-32H Code ID (Default:K) Format 20H-7EH Standard Code39 Verification Full-featured Code39 Transfer Start / End Character Transmit Check Character *Off Truncate Leading Digit (Default:00) *Off 00H-32H Checksum Truncate Last Digit (Default:00) 00H-32H *Off Select Insertion (Default:00)
Page 15
Enter Enter Code93 Truncate Leading Digit (Default:00) Reading 00H-7EH Truncate Last Digit (Default:00) 00H-7EH Code ID (Default:L) Select Insertion (Default:00) 20H-7EH 00H-02H Verification Start / End Character Type *ABCD/ABCD abcd/to*e Transmit Check Character abcd/abcd Transmit Start / End Character *Off *Off Min.
Enter Enter Interleaved 2 of 5 Truncate Leading Digit (Default:00) Reading 00H-7FH Truncate Last Digit (Default:00) 00H-7FH Code ID (Default:N) Select Insertion (Default:00) 20H-7EH 00H-02H Verification Min. Length (Default:00) 00H-7FH *Off Max. Length (Default:00) Transmit Check Character 00H-7FH...
Enter Enter Industrial 2 of 5 Truncate Leading Digit (Default:00) Reading 00H-32H Truncate Last Digit (Default:00) *Off 00H-32H Code ID (Default:O) Select Insertion (Default:00) 00H-7EH 00H-02H Verification Min. Length (Default:00) 00H-32H *Off Max. Length (Default:00) Transmit Check Character 00H-32H *Off...
Enter Enter Matrix 2 of 5 Truncate Leading Digit (Default:00) Reading 00H-50H Truncate Last Digit (Default:00) *Off 00H-50H Code ID (Default:P) Select Insertion 20H-7EH 00H-02H Verification Min. Length (Default:00) 00H-50H *Off Max. Length (Default:50H) Transmit Check Character 00H-50H...
Enter Enter China Post Code Truncate Leading Digit (Default:00) Reading 00H-50H Truncate Last Digit (Default:00) *Off 00H-50H Code ID (Default:Q) Select Insertion (Default:00) 20H-7EH 00H-02H Verification Min. Length (Default:00) 00H-50H *Off Max. Length (Default:50H) Transmit Check Character 00H-50H *Off...
Enter Enter MSI / Plessey Truncate Leading Digit (Default:00) Reading 00H-3CH Truncate Last Digit (Default:00) *Off 00H-3CH Code ID (Default:R) Select Insertion (Default:00) 20H-7EH 00H-02H Verification Min. Length (Default:00) *Off 00H-3CH MOD 10 Max. Length (Default:3CH) MOD 11/10 00H-3CH MOD 10/10 Transmit Check Character...
Enter Enter APPENDIX A -- ASCII Truncate Leading Digit (Default:00) 00H-50H Truncate Last Digit (Default:00) 00H-50H Select Insertion 00H-02H Min. Length (Default:00) 00H-50H Max. Length (Default:50H) 00H-50H Confirm...