Warmwasserspeicher | charging station for dhW cylinders | station de charge pour ballon d’eau chaude sanitaire | laadstation voor warmwaterboiler | Ohřívací stanice pro ohřívač vody » Wts 30 e » Wts 40 e...
contents | Operation general information general information oPeration �������������������������������������������������������� 12 General information ��������������������������������������� 12 document information Document information ����������������������������������������� 12 Other relevant documents ������������������������������������ 12 The chapter operation is intended for users and heating Key to symbols �������������������������������������������������� 12 contractors. Safety ��������������������������������������������������������...
Operation Safety safety device description DHW heating via primary station with plate heat exchanger system intended use for heating floorstanding DHW cylinders. On the primary side for heat pump heating and on the secondary side for cylinder heating, This appliance is solely designed for the transfer of heat from the both equipped with a circulation pump.
Installation Safety safety 7.1.2 dHw cylinder circuit Only qualified contractors should carry out installation, commissioning, maintenance and repair of the appliance. CAUTION Risk of injury through burns! Contact with hot components can lead to burns. Therefore: - When working on hot components, always wear protective working clothing and gloves.
Installation Installation installation 7.3.2 dHw cylinder circuit installation conditions and preparations Ensure that: - The pipe runs are kept as short as possible. - The selected pipe cross-sections are not smaller than the connections at the appliance. CAUTION Risk of damage through foreign bodies Ensure that the system is flushed.
Installation Installation f Remove the wall mounting bracket from the lower shell, and water connection secure it to the wall with the 8x70 screws and washers. CAUTION Risk of damage through water Carry out all water connection and installation work in accordance with regulations.
Installation commissioning Power supply f Check the function of the safety valve. f Carefully vent the appliance on the DHW side by cracking Only qualified electricians must carry out the connection in open the safety valve. accordance with these instructions. 10.3 checking the system for leaks WARNING Risk to life through electrocution! f Prior to handover, check the complete system for tightness.
Installation Specification 13.2 data table WTS 30 e WTS 40 e 232907 232908 Application limits Max. permissible temperature, primary side °C Max. permissible temperature, secondary side °C Hydraulic data Nominal flow rate, primary side m³/h Nominal flow rate, secondary side m³/h...
Page 9
Installation Specification dimensions wts 30 e WTS 30 e Heat pump flow G 1 ¼ Heat pump return G 1 ¼ Cylinder flow G 1 ¼ Cylinder return G 1 ¼ wWW.STIeBel-elTROn.cOM WTS | 21...
Page 10
Installation Specification dimensions wts 40 e WTS 40 e Heat pump flow G 1 ¼ Heat pump return G 1 ¼ Cylinder flow G 1 ¼ Cylinder return G 1 ¼ |WTS WWW.STIeBel-elTROn.cOM...
Warranty Environment and recycling Warranty The warranty conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products, it is increasingly the case that warranties can only be issued by those subsidiaries. Such warranties are only granted if the subsidiary has issued its own terms of warranty.