Download Print this page
Elkay ERPA2-8C*A Installation, Care & Use Manual

Elkay ERPA2-8C*A Installation, Care & Use Manual

Swirlflo refrigerated fountains with flexi-guard

Advertisement

Quick Links

ERPA2-8C*A ERPA2-8RAC*A ERPAVR2-8C*A ERPAVR2-8RAC*A LPTEA8C*A LPTEA8RAC*A
Installation/Care/Use Manual
®
SwirlFlo
ERPA2-8C, LPTEA8C
Installer
To assure you install this model easily and correctly, PLEASE READ
THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLA-
TION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After
installation, leave these instructions inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-
TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
3/8" O.D. UNPLATED
1/4" O.D. TUBE
COPPER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
FIG. 1
DIRECTION
48
FIG. 3
Refrigerated Fountains with FLEXI-GUARD
SEE FIG. 11
IMPORTANT
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
45
BASIN
46
1
47
FIG. 4
42
37, 39, 41
ERPA2-8RAC, LPTEA8RAC
FIG. 2
NOTE: WHEN INSTALLING
REPLACEMENT BUBBLER
3
AND PEDESTAL, TIGHTEN
NUT (ITEM 5 OR 33) ONLY
TO HOLD PARTS SNUG
2
4
IN POSITION. DO NOT
OVER TIGHTEN.
5
®
SEE FIG. 4 OR 5
38, 40, 41
35
44
36
44
51
49
33
FIG. 5
97876C (REV. D - 12/04)

Advertisement

loading

Summary of Contents for Elkay ERPA2-8C*A

  • Page 1 ERPA2-8C*A ERPA2-8RAC*A ERPAVR2-8C*A ERPAVR2-8RAC*A LPTEA8C*A LPTEA8RAC*A Installation/Care/Use Manual ® ® SwirlFlo Refrigerated Fountains with FLEXI-GUARD SEE FIG. 4 OR 5 38, 40, 41 SEE FIG. 11 37, 39, 41 ERPA2-8C, LPTEA8C ERPA2-8RAC, LPTEA8RAC Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLA- TION.
  • Page 2 ERPA2-8C*A ERPA2-8RAC*A ERPAVR2-8C*A ERPAVR2-8RAC*A LPTEA8C*A LPTEA8RAC*A FIG. 6 97876C (REV. D - 12/04) PAGE 2...
  • Page 3 ERPA2-8C*A ERPA2-8RAC*A ERPAVR2-8C*A ERPAVR2-8RAC*A LPTEA8C*A LPTEA8RAC*A INSTALLATION INSTRUCTIONS 1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left side of shelf. (See Figure 6) NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller.
  • Page 4 ERPA2-8C*A ERPA2-8RAC*A ERPAVR2-8C*A ERPAVR2-8RAC*A LPTEA8C*A LPTEA8RAC*A PARTS LIST ITEM NO. PART NO. DESCRIPTION 56073C Bubbler Assy 40322C Orifice Assy 56011C Housing Assembly 55997C Pedestal 75580C Bubbler Locknut 28322C Push Bar Mounting Bracket 21810C Push Bar Assy 28324C Regulator Activator Arm 70426C Screw - #8-32 X .25 THMS...

This manual is also suitable for:

Erpa2-8rac*aErpavr2-8c*aLptea8c*aErpavr2-8rac*aLptea8rac*a