INITIAL STEPS FOR INSTALLING YOUR DRYER
Part 3
Connecting the Exhaust
STEP 3
and Venting System.
WARNING!
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can
result in death or fire.
Clean old ducts before installing this dryer
Note
Vent end will face to the outside home and
improper taping and unstable installation of vent
will cause undesirable drying performance.
In addition to the following warnings, please refer
to manual section on Exhaust Requirements and
Maintenance. IMPORTANT: To reduce the risk of
fire, combustion, and gas accumulation, the dryer
must be vented to the outdoors. Please follow the
instructions (and all others in this manual) very
carefully.
• Do not use thin plastic or foil ducting.
• Rigid or semi-rigid metal ducting is recommended for
use as transition ducting between the dryer and and the
wall. In special installations when it is impossible to
make a connection with the above recommendations,
then a UL-listed flexible metal transition duct may be
used between the dryer and wall connection only. The
use of this ducting will affect dry time.
Position the Dryer such that the exhaust duct run is
as short as possible.
Clean old ducts before installing this dryer
The male end of each section of exhaust duct must
point away from the dryer
Use as few elbow joints as possible.
Use duct tape on all duct joints
Insulate ductwork that runs through unheated
areas in order to reduce condensation and lint
build-up on pipe walls; and
PLEASE BE AWARE THAT FAILURE TO
EXHAUST THE DRYER CORRECTLY WILL
VOID THE DRYER S WARRANTY.
ALTERNATE EXHAUST DIRECTIONS
1.
Remove a screw and exhaust duct.
2-1.
Detach and remove the knockout that
matches the desired venting direction
(Right side not available on Gas Dryers)
, ,
the order of work.
2-2.
Reconnect the duct to the blower
housing and attach the duct to the
base.(Duct is a SVC part)
3-1.
Pre-assemble 4" elbow with 4" duct.
Wrap duct tape around joint.
3-2.
Insert elbow duct assembly first through the
side opening and connect the elbow to the
internal duct.