"WARNING - To Reduce The Risk Of Electric Shock,
Do Not Use This Fan With Any Solid-State Speed Control Device."
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means
to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
b) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
c) Ducted fans must always be vented to the outdoors.
d) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be
connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
a) "Do not install fan above or inside a 45-degree
angle projected outwards from the cooking equip-
ment element closest to the fan. See instruction
sheet for clarification;" or
b) "Not for use in cooking area - see installation
instructions;"
" Do Not Mount In A Ceiling Thermally Insulated To A Value Greater Than R40"
"CAUTION - For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors."
WARRANTY OWNER: Orbit Industries, Inc., warrants to the original consumer purchaser that it's products will be free from
defects in materials or workmanship for a period of one year from the date of original consumer purchase.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, Orbit, will at its option, repair or replace , without charge, any products or part which is found to be
defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR
TUBES, FILTERS, DUCT, ROOF CAPS, and OTHER ACCESSORIES FOR DUCTING.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to
misuse, negligence, accident, improper maintenance of repair (other than by Orbit), faulty installation or installation contrary to
recommended installation instructions. The duration of any implied warranty is limited to the one year period as specified for the
express warranty. Orbit OBLIGATION TO REPAIR OR REPLACE, AT Orbit OPTION, LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR
PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusive may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which
vary from state to state. This warranty supercedes all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify Orbit at the address stated below, (b) give the
model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
Orbit Industries, Inc. 2100 S. Figueroa St.
READ AND SAVE THESE INSTRUCTIONS
WARNING:
Los Angeles, CA 90007
INSULATION*
(Place around and
over Fan Housing.)
POWER
HOUSING
CABLE*
Seal gaps
around
Housing.
ROUND
DUCT*
Seal duct
*
Purchase
joints with
tape.
separately
Recommended to put insulation around and the fan housing to
minimize the building heat loss. Seal all the gaps around the
housing with caulk or other similar material to inhibit air leakage
to the exterior of the thermal envelope of the building. Rigid sheet
metal duct and the shortest path to the outside will minimize
static pressure losses and promote adequate flow.
Tel: (213) 745-8884
Fax: (213) 745-2015 1-800-90-ORBIT
ROOF CAP*
(with built-in
damper)
FAN
Keep duct
runs short
WALL CAP*
(with built-in
ROUND
damper)
ELBOW(S) *
Deluxe
ODU814M

Advertisement

loading

Summary of Contents for Orbit Deluxe ODU814M

  • Page 1 WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, Orbit, will at its option, repair or replace , without charge, any products or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, and OTHER ACCESSORIES FOR DUCTING.
  • Page 2 Deluxe ODU814M 4” & 6” Termination (duct) Carefully position fan Rough Opening: for shortest duct run and 11-1/4” L X 10-1/2” W fewest elbows to achieve Housing Dimension: 11-1/4” L X 10-1/2” W X 7-5/8” H maximum performance 1. Remove grille from housing before installation. 1.
  • Page 3: Service Parts

    Deluxe ODU814M OPERATION: Power box Timer Delay Knob The control box, located inside the fan housing, has three separate adjustments: Dip Switch Low Airflow (1) The low airflow knob (S) adjusts the lower airflow from 30CFM up to Knob the air flow rate of the high fan speed determined by the dip switch setting. (2) The time delay knob (T) is adjustable from 3 to 30 minutes and will switch the fan Switch position...
  • Page 4: Wiring Diagram

    Deluxe ODU814M WIRING: Power must be disconnected during installation. 1. Run electrical as directly as possible from the wall switch to the unit. 2. Using approved connectors, connect cables wires according to the model and diagram below to the junction box. 3.