  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 PXIS-2700 3U 18-Slot PXI Chassis and Accessories User’s Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 @Copyright 2003 ADLINK Technology Inc. All Rights Reserved. Manual Rev. 1.00: December 12, 2003 Part No. 50-17003-100 The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of the manufacturer.
  • Page 4 Getting Service from ADLINK Customer Satisfaction is top priority for ADLINK TECHNOLOGY INC. If you need any help or service, please contact us. ADLINK TECHNOLOGY INC. Web Site http://www.adlinktech.com Sales & Service Service@adlinktech.com +886-2-82265877 +886-2-82265717 Address 9F, No. 166, Jian Yi Road, Chungho City, Taipei, 235 Taiwan Please email or FAX your detailed information for prompt, satisfactory, and consistent service.
  • Page 5: Table Of Contents

    Peripheral Slots ..............10 Local Bus ................10 Trigger Bus ................10 System Reference Clock ............12 Chapter 4 Troubleshooting and Preventative Maintenance ............13 Troubleshooting the PXIS-2700 ........... 13 Cleaning ................. 13 4.2.1 Interior Cleaning..............14 4.2.2 Exterior Cleaning..............14 4.3 Temperature Detection.............
  • Page 6 B.3.2 Miscellaneous Connectors Pin Assignments ....28 SAFETY INSTRUCTIONS..........30 Warranty Policy............33 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 7 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8: Chapter 1 Introduction

    (Mean-Time-To-Repair). The PXI-3710 (3-slot version, without floppy disk drive) and PXI-3710F (4- slot version, with floppy disk drive) are designed to fit in the PXIS-2700 chassis. With all the powerful and convenient design, the PXIS-2700 is ideal for high performance applications and a large number of I/O modules.
  • Page 9: Unpacking Checklist

    Two PXI-to-PXI bridges Figure 1-1, 1-2 show some of the feature, and components of the PXIS- 2700 chassis. Figure 1-1 shows the front view of the PXIS-2700. Figure 1- 2 shows the rear view of the PXIS-2700. 2 ● Introduction...
  • Page 10 Figure 1-1 Front View of the PXIS-2700 chassis Figure 1-2 Rear View of the PXIS-2700 chassis Introduction ● 3 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 11: Oem Options

    1.3 OEM options The standard PXIS-2700 chassis includes backplanes and a power supply unit in addition to the enclosure metal parts. The following sections depict the standard parts used in the PXIS-2700. 1.3.1 Backplane PXIS-2700 equipped with cBX-3018L, 18-slot PXI backplane. Please refer to Appendix B for more technical information of the backplane.
  • Page 12: Chapter 2 Installation

    Installation 2.1 Power Budget Consideration Prior to installing any cards into the PXIS-2700 chassis, please calculate the system power requirement. The power budget for every DC power sources shall also be checked, including +5V, +3.3V, +12V, -12V supply rail. Please refer to Appendix A for the maximum usable power.
  • Page 13: System Monitoring

    2.3 System Monitoring There are LEDs on the front panel for system monitoring, including powers, temperature, and fans. Please refer to following for the detailed meaning of display status on LEDs. System Monitoring Power LED (Voltage : 3.3V, 5V, +12V, -12V) Color: Green ON while supplied Temperature LED...
  • Page 14: Grounding On The Mounting Holes

    The backplane is mounted on the PXIS-2700 through all mounting holes by default, therefore the chassis ground is short to the logic ground. For applications that require isolation between the logic ground and the chassis ground, users can remove the screws on the GND mounting holes.
  • Page 15 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16: Chapter 3 Backplane Overview

    CompactPCI 64-bit specification are found on PXI-specific signals. Therefore, all modules that meet the requirements of the CompactPCI 64-bit specification will function in the PXIS-2700. 3.2 System Controller Slot The System Controller slot is Slot 1 of the chassis as defined by the PXI specification.
  • Page 17: Peripheral Slots

    1 and 2. 3.6 Trigger Bus ADLINK PXIS-2700 has three PXI separate trigger bus segments. The PXI trigger bus is divided into three separate trigger bus at these locations. The trigger bus divisions represented by vertical bars on the front of the chassis.
  • Page 18 Figure 3.1 PXI Local Bus and Star Trigger Routing Backplane Overview • 11 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 19: System Reference Clock

    3.7 System Reference Clock The PXIS-2700 supplies the PXI 10MHz system clock signal (PXI_CLK10) independently to every peripheral slot. An independent buffer (having a source impedance matched to the backplane and a skew of less than 1ns between slots) drives the clock signal to each peripheral slot. Users can...
  • Page 20: Chapter 4 Troubleshooting And Preventative Maintenance

    Troubleshooting and Preventative Maintenance 4.1 Troubleshooting the PXIS-2700 Please refer to Table 4.1 to troubleshoot the PXIS-2700 chassis. The table lists possible causes for power failure and recommends ways to correct the problem. Table 4.1 Troubleshooting Possible Cause What to Do...
  • Page 21: Interior Cleaning

    Note: Always power-off the chassis and disconnect the power cord before cleaning of servicing the chassis. 4.2.1 Interior Cleaning Use a dry, low-velocity stream of air for cleaning the interior of the chassis. Clean around components with a soft-bristle brush. If you must use a liquid for minor interior cleaning, use a 75% isopropyl alcohol solution and rinse with deionized water.
  • Page 22: Power Supply Unit Hot-Swap Replacement

    4.5 Power Supply Unit Hot-Swap Replacement For the PXIS-2700 chassis, there are four Green LED indicators for 3.3V, 5V, +12V, and -12V. There is also a Green LED for each power supply unit on the rear panel. The power unit is defective if the LED on the rear panel is extinguished or if the buzzer beeps continuously.
  • Page 23 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24: Appendix A Specifications

    Specifications Complies with PXI specifications and accepts modules compliant with CompactPCI, PICMG 2.0 specifications. Electrical AC Power Supply 460W + 460W hot swappable 1+1 redundant power supply Input voltage: 90-264V universal, full range Input frequency: 47 to 63Hz Input current per power module for 230V for 115V Inrush current per power module...
  • Page 25 International standards of power supply Safety: UL 1950/CSA 22.2 No. 950, TUV IEC 950 EMI: FCC Class B, CISPR22 Class B Efficiency: Typically 65% at full load Power supply dimension: 195 (D) mm x 356 (W) mm x 99 (H) mm Over-Load protection Over Current Protection Over Voltage Protection...
  • Page 26 Number of controller expansion slots: 3 (left of controller slot) Dimensions: 445mm x 482.6mm x 177.8 mm (L x W x H, w/o handle) Weight: 19kg Figure A.1 PXIS-2700 Dimensions Operating Environment Ambient temperature range: 0 to 40°C Relative humidity: 10 to 90%, non-condensing Storage Environment Temperature Ambient temperature range: -20 to 70°C...
  • Page 27 Backplane bare-board material: UL 94V-0 rated Backplane connectors: Conforms to IEC-917 and IEC 1076-4-101,UL 94V-0 rated Number of PXI/CompactPCI slots: 18 (1 controller, 17 peripherals) PXI peripheral slots with star trigger signals: from the 3rd slot to the 15th slot PXI trigger bus segments: 3 (slot 1-6, slot 7-12, slot 13-18) PXI local bus: All Number of PXI-to-PXI bridges: 2...
  • Page 28: Appendix B Backplane Drawing And Pin Assignments

    Backplane Drawing and Pin Assignments B.1 Backplane Mechanical Drawing The following figures show the two parts of the backplanes and Mechanical Drawing. 11 12 13 14 15 16 17 18 3 4 5 1 2 3 4 5 6 Figure B.1 cBX-3018L front view Drawing Pin Assignments •...
  • Page 29 17 16 15 14 13 12 11 10 7 6 5 4 3 2 Figure B.2 cBX-3018L rear view Drawing 22 ● Pin Assignments Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 30: Pxi / Pci Bus Architecture

    B.2 PXI / PCI Bus Architecture PXI System Slot 1 Primary PCI Bus / Slot 2 Trigger Bus Controller Primary PCI Bus / Slot 3 64-bit PCI PXI Trigger bus Primary PCI Bus / Slot 4 (Group 1) Primary PCI Bus / Slot 5 Primary PCI Bus / Slot 6 CBX-R3018L Daisy chained...
  • Page 31: Backplane Cbx-3018L Connectors Pin Assignments

    B.3 Backplane cBX-3018L Connectors Pin Assignments B.3.1 PXI Connectors Pin Assignments System Slot (Slot #1) P1 Pin Assignment REQ64# ENUM# +3.3V AD[1] V(I/O) AD[0] ACK64# +3.3V AD[4] AD[3] AD[2] AD[7] +3.3V AD[6] AD[5] +3.3V AD[9] AD[8] C/BE[0]# AD[12] V(I/O) AD[11] AD[10] +3.3V AD[15]...
  • Page 32 CLK4 GNT3# REQ4# GNT4# CLK2 CLK3 GNT2# REQ3# GND (SYS#) CLK1 REQ1# GNT1# REQ2# Star Trigger Slot (Slot #2) P1 Pin Assignment REQ64# ENUM# +3.3V AD[1] V(I/O) AD[0] ACK64# +3.3V AD[4] AD[3] AD[2] AD[7] +3.3V AD[6] AD[5] +3.3V AD[9] AD[8] M66EN C/BE[0]# AD[12]...
  • Page 33 PXI_BRSVB4 V(I/O) C/BE[7]# C/BE[6]# PXI_LBR7 PXI_LBR8 PXI_LBR9 PXI_LBR10 PXI_LBR11 PXI_LBR12 N.C (SYS#) PXI_STAR7 PXI_STAR8 PXI_STAR9 PXI_STAR10 PXI_STAR11 PXI_STAR12 General Peripheral Slot (Slot #3~#6) P1 Pin Assignment REQ64# ENUM# +3.3V AD[1] V(I/O) AD[0] ACK64# +3.3V AD[4] AD[3] AD[2] AD[7] +3.3V AD[6] AD[5] +3.3V AD[9]...
  • Page 34 C/BE[5]# V(I/O) C/BE[4]# PAR64 PXI_BRSVB4 V(I/O) C/BE[7]# C/BE[6]# PXI_LBR7 PXI_LBR8 PXI_LBR9 PXI_LBR10 PXI_LBR11 PXI_LBR12 N/C (SYS#) PXI_LBL7 PXI_LBL8 PXI_LBL9 PXI_LBL10 PXI_LBL11 PXI_LBL12 Note 1: Please refer the following table for the routing of the Bus Mastering (REQ/GNT), IDSEL, PCI CLK and Interrupt signals. Slot # IDSEL REQ#...
  • Page 35 Slot 14 PXI_STAR11 Slot 15 PXI_STAR12 Slot 16 (No Star Trigger) Slot 17 (No Star Trigger) Slot 18 (No Star Trigger) B.3.2 Miscellaneous Connectors Pin Assignments CN1, CN7: ATX-like DC Power input connectors Signal Name Pin # Pin # Signal Name V2SENSE V2 (+3.3V) V2 (+3.3V)
  • Page 36 Pin # Signal Name FAL# J5: Connector for LED power status Name Pin # Pin # Name +3.3V -12V +12V CN2: SMB (system managing bus) connector Pin # Name IPMB_CLK IPMB_DATA IPMB_PWR ALERT The SMB is connected to the P2 of the system slot. JP1: 10MHz Reference Clock Pin # Name...
  • Page 37 SAFETY INSTRUCTIONS Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use. Please read these safety instructions carefully. Please keep this User‘s Manual for later reference. The equipment can be operated at an ambient temperature of 40ºC.
  • Page 38 a service personnel: The Power cord or plug is damaged. Liquid has penetrated into the equipment. The equipment has been exposed to moisture. The equipment has not work well or you can not get it work according to user‘s manual. The equipment has dropped and damaged.
  • Page 39 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 40 Warranty Policy Thank you for choosing ADLINK. To understand your rights and enjoy all the after- sales services we offer, please read the following carefully: Before using ADLINK’s products please read the user manual and follow the instructions exactly. When sending in damaged products for repair, please attach an RMA application form.
  • Page 41 RMA Request & Confirmation Form Page 1 of 2 Dear Customer, Please fill out and fax back this form to obtain the RMA number for your returned or repaired product. Thank you very much! Your Company Name : Your Name : Invoice No.
  • Page 42 Ship separately by air parcel (Note: we do not accept liability for items shipped by air parcel) Other ___________________________________ ADLINK Technology Inc. Accepted & Confirmed by Warranty Policy • 35 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 43 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...

Table of Contents