Page 1
Ma n u a l T e mp e r a t u r e s e n s o r P R - S P A - E X - WK F...
Page 2
The supply lines (connecting wires) have to be installed strain-relieved. The sensor user must specify the used protection type and document it carefully. EPHY-MESS GmbH • Berta-Cramer-Ring 1• 65205 Wiesbaden • Germany • phone: +49 6122 9228-0 fax: +49 6122 9228-99 • info@ephy-mess.de...
Page 3
Otherwise, the self-heating must be observed so that the permissible maximum temperature is not exceeded and measurement errors are avoided. 23.06.2017 Manual - IBExU 14 ATEX 1281 U - IECEx IBE 14.0058 U - PR-SPA-EX-WKF Page 2 of 11...
Page 4
** As an example we take 1 mA, because generally a measuring current of 1 mA is not exceeded. 23.06.2017 Manual - IBExU 14 ATEX 1281 U - IECEx IBE 14.0058 U - PR-SPA-EX-WKF Page 3 of 11...
Page 5
The power supply must have a connection adequate to the thermometer’s type of circuit (2- 3- or 4- wire circuit). 23.06.2017 Manual - IBExU 14 ATEX 1281 U - IECEx IBE 14.0058 U - PR-SPA-EX-WKF Page 4 of 11...
Page 6
Teflon clamp ring. The connecting cables must be laid straight and without loops. It is not allowed to connect, install or apply the PR-SPA-EX-WKF sensor in another way than described under item 4 and 5.
Page 7
-55°C/-60°C … +180°C temperature Thermocouple (TE) Measuring circuits: 1 or 2 Max. voltage: 1.5 V Max. current: 100 mA Max. power: 25 mW 23.06.2017 Manual - IBExU 14 ATEX 1281 U - IECEx IBE 14.0058 U - PR-SPA-EX-WKF Page 6 of 11...
Page 8
Insulation: Teflon or silicone Color code: acc. to DIN or resp. customer’s request ≥ AWG 30 Cross section: 23.06.2017 Manual - IBExU 14 ATEX 1281 U - IECEx IBE 14.0058 U - PR-SPA-EX-WKF Page 7 of 11...
Page 9
Design Version depending on the point of installation see 8. Variant identification WKF: sensor for winding head EX-certification Sensor, passive Product 23.06.2017 Manual - IBExU 14 ATEX 1281 U - IECEx IBE 14.0058 U - PR-SPA-EX-WKF Page 8 of 11...
Page 10
1) Addition. E. g.: In KTY also be asked to specify color code and polarity of the line e. g.: YE (+) / GN (-) 23.06.2017 Manual - IBExU 14 ATEX 1281 U - IECEx IBE 14.0058 U - PR-SPA-EX-WKF Page 9 of 11...
Page 11
) EN 60584 BK(BK / WH ) EN 60584 GN(GN / WH ) EN 60584 OR(OR / WH ) EN 60584 23.06.2017 Manual - IBExU 14 ATEX 1281 U - IECEx IBE 14.0058 U - PR-SPA-EX-WKF Page 10 of 11...
Page 12
9.3.2 Connection diagram equipment protection by intrinsic safety (Use of a suitable operating equipment) supply unit Pt100 measuring resistor Wiesbaden, 23 of June 2017 23.06.2017 Manual - IBExU 14 ATEX 1281 U - IECEx IBE 14.0058 U - PR-SPA-EX-WKF Page 11 of 11...