Funkwerk TRT800RT Operation And Installation

Remote control unit

Advertisement

Quick Links

TRT800RT - OLED
Remote Control Unit
P/N 800ATC-H-(Rxx)-(Rxx)
Operation and Installation
(Document-No. 03.202.010.71e)

Advertisement

Table of Contents
loading

Summary of Contents for Funkwerk TRT800RT

  • Page 1 TRT800RT - OLED Remote Control Unit P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation (Document-No. 03.202.010.71e)
  • Page 3 TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Change History Revision Date Description of Change 1.00 22.10.2012 First Release List of Service-Bulletins (SB) Service Bulletins have to be inserted into this manual and to be enlisted in the following table. Rev.
  • Page 4: Table Of Contents

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Table of Contents GENERAL....................4 Symbols ................... 4 Abbreviations ................... 5 Customer Support ................6 Features ................... 6 OPERATION....................7 Controls.................... 7 Switch ON/OFF ................9 Display - Indications ............... 10 Display-Brightness ................. 11 Flight-ID (FID) ................
  • Page 5: General

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation GENERAL This manual contains information about the physical, mechanical and electrical characteristics and about installation and operation of the transponder remote control TRT800RT. Symbols Advices whose non-observance can cause radiation damage to the human body or ignition of combustible...
  • Page 6: Abbreviations

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Abbreviations Abb. Meaning Explanation Flight ID Flight plan number or if not assigned registration number of aircraft Special Position Activation on request by controllers Identification „Squawk Ident“, transmits SPI Pulse for 18 seconds, which highlights the...
  • Page 7: Customer Support

    Any suggestions for improvement of our manuals are welcome. Contact: service@funkwerk-avionics.com. Informations on software updates are available at Funkwerk Avionics Features Remote control and indication of all transponder settings/data during standard operation (e.g. squawk code, operation mode, altitude etc).
  • Page 8: Operation

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation OPERATION Controls If remote unit settings are inconsistent with transponder settings as a result of short time transmission problem (e.g. simultaneous user inputs) remote unit settings will be reverted to current transponder setting.
  • Page 9 TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation ► Switch ON press button for approx. 0,5 s ON/OFF ► Switch OFF press button for approx. 3 s ► activate/deactivate VFR Squawk (press shortly) store active Squawk as VFR/VFRW-Squawk ► (press button 3 s, →2.8) ►...
  • Page 10: Switch On/Off

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Switch ON/OFF Switch ON: press I/O for 0.5 s Switch OFF: press I/O for 3 s 2.2.1 Display information after power up After turning-on the display appears as follows (example): Device Name TRT800RT.
  • Page 11: Display - Indications

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Display - Indications Operational Mode: Lock out Reply Active Squawk Active indication indication 7000 PLL/TRX/ DC BAT/DIM Backlight setup SPI indicator FL 030 Low battery ind. STBY 2000 Flight level GND switch Operational Mode...
  • Page 12: Display-Brightness

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Error indicators PLL Error Internal Error Transmit Failure Check antenna and wiring Low internal voltage Internal error FPGA-Failure Internal error Battery Power too low maybe battery/generator fault Note: Short time indication symbols (e.g. lock-out indication or reply indication) are displayed/cleared in different time interval or delayed in comparison with TRT800H screen.
  • Page 13: Display Flight-Id

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation 2.5.1 Display Flight-ID Press MODE (repeatedly) until „STBY“ appears Press and hold ID while a counter is shown beside the active squawk. During a few seconds Flight Identification is displayed A B C D E F G H 2.5.2...
  • Page 14: Transponder Mode Selection

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Transponder Mode selection Press MODE (repeatedly) to select from following Modes: • STBY „Standby“ Transponder does not respond to any interrogation. Squitter and ADS-B output is not active. • ACS „Mode A+C+S“ Standard condition; transponder responds to mode A, C and S interrogations.
  • Page 15: Vfr - Squawk

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation VFR – Squawk The transponder features a user-defined squawk code for VFR-flight (factory setting: 7000): • Activate VFR-Squawk: Press („VFR“ is indicated), now the active Squawk is moved into Standby but not visible because the indication of the Standby Squawk is overlapped by „VFR“...
  • Page 16: Installation

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation INSTALLATION Notes The following suggestions should be considered before installing. The assigned installation company will supply wiring. For diagrams refer to 3.6 Wiring. Remote Header and cables shall be installed according to „FAA AC- 143.13-2A Acceptable Methods, Techniques and Practices –...
  • Page 17: Mounting

    • In cooperation with a maintenance shop, location and kind of the installation are specified. The maintenance shop can supply all cables. Suitable sets of cables are available from Funkwerk Avionics GmbH. • Select a position away from heat sources. Care for adequate convection cooling.
  • Page 18: Equipment Connections

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Equipment Connections 3.5.1 Electrical Connections One 9 pin D-SUB miniature connector includes all electrical connections. When powering the remote control not by the output of the switched power output of the remote controlled device but directly by the aircraft’s power supply, the power input line...
  • Page 19: Post-Installation Check

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Post-Installation Check A certified maintenance shop must verify proper operation of remote control header”. All steering and control functions of the aircraft are to be examined, in order to exclude disturbances by the wiring.
  • Page 20: Drawings

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Drawings 3.8.1 Dimensions 3.8.2 Mounting Advices Fixing clips (spring) left / right Connector (plug) has to be clamped with both spring locks. New screws may be turned in more than max. 15mm into the device –...
  • Page 21: Appendix

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation APPENDIX Technical Data Compliance CS-ETSO-2C112a EASA.21O.269 Applicable Documents CS-ETSO-2C112a EUROCAE ED-73B Class 1 Level 2es EUROCAE ED-26 RTCA DO-160D RTCA DO-178B Software-Level D Temperature Ranges Operation -20 °C to +55 °C; for 30 min +70°C Storage -55 °C to +85 °C...
  • Page 22: Environmental Conditions

    TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Environmental Conditions Characteristic DO–160D Section Cat. Condition Temperature / Altitude Low ground survival 4.5.1 – 55°C temperature Low operating temperature 4.5.1 – 20°C High ground survival 4.5.2 + 85°C Temperature High Short-time Operating 4.5.2...
  • Page 23 TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Characteristic DO–160D Section Cat. Condition Induced Signal Susceptibility 19.0 Radio Frequency 20.0 Susceptibility Emission of RF Energy 21.0 Lightning Induced Transient 22.0 B3F3 Susceptibility Lightning Direct Effects 23.0 No test required Icing 24.0 No test required Electrostatic Discharge (ESD) 25.0...
  • Page 24 TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx) Operation and Installation Notes: Document-No: 03.202.010.71e / Revision: 1.00...
  • Page 25 Funkwerk Avionics GmbH Heinz-Strachowitz-Str. 4 DE-86807 Buchloe Germany phone.: +49-8241 80066 0 fax.: +49-8241 80066 99 E-mail: service@funkwerk-avionics.com www.funkwerk-avionics.com...

Table of Contents