SB-593 Satellite Board
2.0

Cable Requirements

two conductor, stranded, AWG 22 or a larger gauge for all input/output connections
NOTE: The Lock Output relay may require a heavier gauge of wire depending upon the current demands of the lock
and the length of the lock wiring run.
3.0
When Installing Satellite Boards
DO
route cables in accessible areas for ease of maintenance
add transient suppression across electric devices attached to a satellite board output
use an isolation relay (Keri Systems P/N IRP-1) if attaching to a parking gate, a turnstile, or any application
using a large electric motor
for a single door application, install the door's reader to the TB-5, "A" reader connection on the controller
for a two door application, install the primary door's reader to the TB-5, "A" reader connection on the
controller and install the secondary door's reader to the TB-6, "B" reader connection on the controller
DO NOT
stretch or over-tension cables
route cables over sharp objects
let cables or wires get tangled
4.0

Jumper Setting

JP12 - Configures the Satellite Board (see Figure 2)
Jumper across JP12, pins 1 and 2, configures the Satellite board for general purpose inputs and outputs.
NO jumper across JP12 configures the Satellite board for second door control with additional inputs and
outputs. When the Satellite board is configured for second door control, the primary door must be connected to
the "A" reader (TB-5 on the PXL-500/PXL-510 controller board) and the secondary door must be connected to
the "B" reader (TB-6 on the controller board).
Figure 2: Satellite Board Jumper Configuration (JP12)