Page 1
Mounting and Servicing Instructions AKO Temperature Regulator selfactuated AKO Three-Way Temperature Regulator with interior Thermostat Balanced, with flange connections Type Series 226.0120 - 226.0149, 226G0120 – 226G0149, 226.0220 – 226.0239, 226.0320 – 226.0329, 226.0420 - 226.0439, 227.0420 – 227.0439 227.0520 – 227.0529 AKO Regelungstechnik GmbH &...
It is vital to comply with these practices and to monitor compliance. AKO Regelungstechnik GmbH & Co KG Friedrich-Sertürner-Straße 14 • D-51377 Leverkusen • Tel.: +49 (0) 214 / 840599-0 • Fax: +49 (0) 214 / 840599-29...
AKO Temperature Regulator selfactuated 3. Scope of Application The use of AKO Temperature Regulators is applicable to all branches of industry in which it is necessary to control systems, i.e. cooling systems and can be used as divider or mixing valves.
AKO Temperature Regulator selfactuated 4. Operating principles AKO Thermostats are equipped with interior, easily exchangeable thermostats which register the temperature of the medium surrounding them at the measuring point (point of installation) and convert it into another physical dimension, namely extension and therefore into a change in distance or length (the valve stroke).
Proper shipping and appropriate storage of the control valves are provided. Note the transport and storage temperature of -25 to 80 ° C. AKO Regelungstechnik GmbH & Co KG Friedrich-Sertürner-Straße 14 • D-51377 Leverkusen • Tel.: +49 (0) 214 / 840599-0 • Fax: +49 (0) 214 / 840599-29...
Refer to the data sheet for applications, limits, limits on use and possibilities. AKO Regelungstechnik GmbH & Co KG Friedrich-Sertürner-Straße 14 • D-51377 Leverkusen • Tel.: +49 (0) 214 / 840599-0 • Fax: +49 (0) 214 / 840599-29...
AKO Temperature Regulator selfactuated 10. Service and Maintenance AKO temperature valves are virtually maintenance free. However, if the medium contains pollutants or deposits occur in the control valve, it may be necessary to clean the control valve at large intervals.
Declaration to regulation EC 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACh) By the REACh-Regulation, the company AKO Regelungstechnik GmbH & Co. KG is only affected as a downstream user. Responsibilities due to the production and Marketing of substances / chemicals for pre-registration or registration are not applicable for us.