  • Page 1 VALVE-REGULATED SEALED LEAD ACID BATTERY Thunder TS... Series TM... Series High Rate Discharge Product Guide...
  • Page 2: Table Of Contents

    Contents Introduction ........01 Products Characteristics .
  • Page 3: Introduction

    Introduction The ABT Thunder TS/TM...W VRLA are batteries according to Eurobat Classification and specially designed for applications which need high power backup. Products Characteristics ABT Thunder TS/TM...W series is specially designed for High Power Rate discharge applications. Designed life at 20 C: TS...W ( 3 5 years)/TM...W (10 years)
  • Page 4: Applications

    Applications Certification Office Machines and computers UPS / EPS GOST Diesel Starting Generator ISO9001 ISO14001 Standards OHSAS18001 IEC61056-1/2 2002 JIS C8702-1/2 2009...
  • Page 5: General Specifications

    General Specifications TS/M...W series Overall Nominal Capacity Height Length Height Weight Width @1.75Vpc/20 C Nominal Watt@10 "end with Terminal Terminal Battery Type Voltage voltage Poles Types Layout 1.60Vpc ,20 C C /Ah C /Ah S 2 46 F1 or F2 T 1 - 7 44 2 58...
  • Page 12: Battery Charging

    This method should not be used when the battery and service entry. load are connected in parallel. If this method is to be used, it is suggested that the ABT technical Effect of temperature on capacity: department is contacted. Rough correction factor of the capacity, according to the temperature, reference temperature being 20 C.
  • Page 13: Charge Characteristics

    Charge Characteristics Temperature Vs Discharge Time Discharge The batteries in the ABT TS/TM...W product range time must be charged at a constant voltage. 10min 0.46 0.53 0.59 0.65 0.74 0.83 0.91 1.00 1.09 1.18 1.25 1.30 At an ambient temperature of 20 C.
  • Page 14: Maintenance

    Storage times: Note: it is recommended that a battery log be The self-discharge of ABT TS/TM...W as a function of maintained, and that records should be temperature is as follows: kept of the total voltage measurements, any mains failures, major battery discharges (current and time) etc.
  • Page 15 /Gel ABT World Wide Our sales growth is due to a complete Global Network with Master distributors and Country managers who apply ABT commercial strategy and through Global Key Account, in Shandong Sacred Sun Power Sources Co. Ltd Add: 1, Shengyang Road, Qufu 273100 China Tel: 86-537-4438 666 extn 6028 Fax:86-537-4411936 Website: www.abtbatt.com www.sacredsun.com...