For any information of a technical or commercial manner, We would like to congratulate and thank you for choosing the contact: BYOU systems. JUMP like all other products in the range it is the fruit of careful AUTOMATISMI BENINCA' SpA BYOU è un marchio di AUTOMATISMI BENINCÀ SpA and accurate choice of materials and components.
If this is the first time you realise an automation for JUMP and weight limits as indicated in this manual in the “Limits garage doors. we recommend that you read this manual of use”...
Note: The content of the package may undergo variations. If in doubt, consult your local dealer. Description of the automation With reference to the list of components in fig.1, fig. 2 shows a typical plant that can be realised using JUMP. Ceiling Sectional door guide...
If this is not the case, replace the state of the door structure. the faulty parts. In no case can the installation of JUMP be consid- • The door structure must be strong and rigid. ered a solution for opening inefficient doors.
Electric connections Fig.5 The cables necessary for the installation of JUMP can vary according to the accessories installed. All of the accessories indicated in the layout in figure 5 are optional. No connection cable is supplied for the accessories. List of cables...
Tools and materials Fig.6 Make sure that there are all tools and materials necessary The length and type of connection cables depend on for installation (fig.6). Also check that they are in compliance the accessories installed (see “Electric connections” with Standards and in perfect working order. paragraph).
Assembly of the drive guide - 2 1) Insert the belt with the track as indicated in figure 14: In all cases, the correctly tensioned belt maintains the position - initially insert the belt tensioning unit; the nut must be posi- along the entire track, without flexion, however giving at slight tioned upwards, so as not to cause friction on the track (detail manual pressure.
Fixing the gear motor to the ceiling - 1 3) Attach the track to the bracket as indicated in figure 21, fix- IMPORTANT: For correct functioning of the automation, ing it using the washers and nuts (detail B), rest the gear motor the gear motor must be fixed in correspondence with on the ground.
Fixing the gear motor to the ceiling - 2 7) Apply the curved bracket JMP.7 to the drive carriage as indi- 12) For excellent fixing it is recommended to use all of the cated in figure 24, blocking it with the screw and nut. holes present on the bracket (10 screws) including the upper ones highlighted Fig.28.
Installation of photocells P.BY Description Make two holes with diameter Pair of photocells for detection of obstacles for automations of 6 mm in a way that the hole in for doors and gates. proximity of the terminal board corresponds to the set-up of The pair is made up of a transmitter (labelled TX) that the cables.
Installation of selector K.BY Description Key selector with control of automations for automatic gates and doors. Wall fixing, customised key. The customised key also has a burglar-resistance function as it is indispensable for opening the selector. Connections A terminal board is installed on the selector for the connection to the Step-by-Step input (PP) of the control unit: No polarity (+/-) has to be respected.
Transmitter BY Description Radio transmitter for the long distance commands for BYOU automations. Functioning The transmitter has three buttons through which it is possible to command the various functions of the automation, configurable in the control unit. Replacing the battery When the signal LED starts to flash it means that the battery...
Control unit CP.JMP connections To make connection easier, the accessory clamps have colours Below it is illustrated how to connect the optional ac- that correspond to those of the control unit. cessories F.BY, K.BY and P.BY. If they are not present, KEY: pass to the next paragraph “Programming”.
Programming the CP.JMP control unit - Introduction Programming of the control unit allows the regulation of all parameters indispensable for the correct functioning of the automation. Programming takes place by means of a series of menus that can be selected from the LCD. A function corresponds to every menu, which will be described successively.
Regulation of the automatic closure time (TCA)...follows Press the [PGM] button to enter the TCA parameter regulation. The display shows the current value of the TCA parameter. 0000 Use the [ ] key to select one of these values: 0 The TCA function is deactivated (default setting). 1 The pause time is set at 10 seconds 0004 2 The pause time is set at 30 seconds...
Step-by-Step functioning mode (PP) It is possible to select two different modes of the Step-by Step command sent from the transmitter or the key selector. Every time the button is pressed in the default mode, the following progression of commands is performed cyclically: OPEN>STOP>CLOSE>STOP>OPEN>...
Resetting the control unit (Res) This function annuls all settings made, taking the control unit back to the initial conditions. It also deletes the settings of the autostart procedure. NOTE: Any remote controls memorised in the radio receiver are not deleted. Press the [PGM] button to access programming or if the control unit is already in the programming menu, press [ ] until the Res function is displayed.
Complete deletion of the receiver memory (RADI>RTR) To delete the memory completely, eliminating all previously-inserted remote controls, proceed as follows: Press the [PGM] button to access programming or if the control unit is already in the programming Radi menu, press [ ] until the Radi menu is displayed. PMOT Press the [PGM] button to enter the Radi function.
Inspection and commissioning ALL OPERATIONS DESCRIBED IN THIS PARAGRAPH ARE EXCLUSIVE COMPETENCE OF AUTHORISED BYOU STAFF, IN COMPLIANCE WITH THAT ENVISIONED IN THIS MANUAL AND THE STANDARDS IN FORCE. the type of installation. The respect for the indications given below is indispensable to guarantee the maximum safety of the automation.
What to do if... Below find the most common functioning problems and the relative solutions. : Problem Cause Solution Check for the presence of mains power There is no mains power supply supply -------------------------------------------------- -------------------------------------------------- The control unit is not connected Check all connections to the control unit -------------------------------------------------- --------------------------------------------------...
Whenever the product is put out of service, the legislative provisions in force must be followed regarding differentiated disposal and re-cycling of the various components (metals, plastics, electric cables, etc.). It is advised to contact a BYOU specialised technician or a specialised company that is enabled for this purpose.
Page 23
Person authorised to draft the technical documentation: Automatismi Benincà SpA Product type: electromechanical automation with built-in control unit for sectional garage doors Model/type: JUMP Accessories: BY The undersigned Luigi Benincà, as the Legal Officer, declares under his liability that the aforementioned...
Page 24
BYOU è un marchio di Automatismi Benincà SpA via Capitello, 45 • 36066 Sandrigo (VI) ITALY • Tel +39 0444 1510294 • Fax +39 0444 759728 • info@byouweb.com • www.byouweb.com...