5-2-6
CIRCUIT
BREAKERS
Models RGX180 and RGX240 have a pushbutton circuit
breaker and Model RGX240D two pushbutton circuit
1
breakers. Nomrallp, the pushbutton circuit breaker is closed
with the button pushed into the panel to keep the circuit
:
live. If an overcurrent runs. the button comes out to break
the circuit. The circuit can be closed again by simply push-
ing the button in. The circuit breaker is a thermo-sensitive
i
type so. if the temperature inside the circuit breaker is still
high immediately after the circuit has opened, the button
may not be able to be pushed in to the ON position. or ma>-
1
come back out again at once. In that case, wait a while until
the inside temperature falls. and then push the button in.
Fig. 5-8
Circuit breaker capacities are as follows:
1
Model
Specification
Circuit Breaker
'
Quantity
Capacity
per Unit
RGX180
11ov.
120v
15A
'
1
RGX180
,
22OV, 23OV. 240V
8A
1
I
RGX240
1 lOV, 120v
20A
1
RGX240
220V. 230V. 240V
10A
1
RGX240D
11 Ol22OV. 12Ol24OV
10A
2
Table 5-3
- 16 -