Common rechargeable batteries contain lithium battery, nickel cadmium battery, nickel metal hydride
battery, and sealed lead-acid battery, etc.
Lithium battery has the features such as big capacity, light weight, high cycle times etc, is widely used in
mobile phones, PDA, digital cameras, camcorders, laptop computers, and other fields, and it is currently
the most advanced rechargeable battery; The lithium battery which is referred to here is finished lithium
one ; The battery which is composed of lithium-ion batteries (lithium ion batteries or polymer batteries)
plus lithium battery protection board is early applicably rechargeable battery, which has the features such
as low cost, low internal resistance, large current discharge.
Nickel metal hydride battery and nickel-cadmium battery are similar, however, since it does not contain
heavy metals, nickel metal hydride battery makes less pollution to the environment than that of
nickel-cadmium battery; At present, nickel metal hydride battery is widely used in common consumer
electronics, and as for the application field, nickel cadmium battery almost has been replaced with nickel
metal hydride battery.
Operating Manual
Applicable Environment of Instrument:
1)Temperature: 0~40℃
2)Operating Altitude: Can be used within altitude 2Km
3)Relative Humidity: 40~80% Humidity
Measuring Range:
1)Testing Range of Battery's Voltage: 0~10V Minimum Resolution
10mV
2)Testing Range of Current:0~3000 mA Minimum Resolution
1mA
3)Testing Range of Internal Resistance:0~1000 mΩ Minimum
Resolution 1mΩ
4)Testing Range of Capacity:0~9999AH Minimum Resolution
1mAH(0.001AH)
Testing Speed:
1)Static Testing(Testing All Functions):3~5 Seconds
2)Capacity Testing(Current Discharge):3~4 Hours
Testing Accuracy:
1)Voltage Testing Accuracy:10.00V±0.1%(After Calibration)
2)Current Testing Accuracy :3A±0.5%
3)Internal Resistance Testing Accuracy:1000mΩ±2%
4) Testing Time: 0-100 Hours Minimum Timekeeping 1 minute (00
Hour:00 Minute)
5)Battery Capacity Testing Accuracy:9999AH ± 2%
Power Supply:15V DC
Standby Power Consumption〈3W

Advertisement

loading

Summary of Contents for Niusiwen AKX2002

  • Page 1 Operating Manual Applicable Environment of Instrument: 1)Temperature: 0~40℃ 2)Operating Altitude: Can be used within altitude 2Km 3)Relative Humidity: 40~80% Humidity Measuring Range: 1)Testing Range of Battery’s Voltage: 0~10V Minimum Resolution 10mV 2)Testing Range of Current:0~3000 mA Minimum Resolution 3)Testing Range of Internal Resistance:0~1000 mΩ Minimum Resolution 1mΩ...
  • Page 2: Internal Resistance

    Small sealed lead-acid battery, also called maintenance-free lead-acid battery, whose current technology is mature, is mainly used in stationary backup power supply occasions such as uninterruptible power supply, emergency lamp and so on. Aimed at the necessary of rechargeable battery production testing, we have specially developed a dedicated rechargeable battery comprehensive tester ;...
  • Page 3 be tested in the same way.) 2.The testing of battery’s internal resistance capacity At firstly, Long press SET, OFF or ON will be shown on window at Lower –left corner; Secondly, press UP and DOWN button to adjust to the ON state (It means that internal resistance test is opened); Then short press SET to save;...
  • Page 4 Maximum Current Testing of Charger, Maximum Current of Tested Charger is 0.86A. The Testing of Battery’s Internal Resistance 125mΩ...
  • Page 5 The Testing of Mobile Phone Battery’s Capacity 1370mAh The Testing of 18650 Battery...
  • Page 6 The Capacity of Mobile Power Supply Is Testing. Notes: 1. The Voltage of Tested Battery Should not be more than 10V; 2. Please insert ahead pen line of Tester when current or capacity is tested with two small ports on the right side; 3.