Page 1
4-20mA or 0-10V - transmitter GIA 010 N GIA 0420 N Operating manual as of version 1.0 WEEE-Reg.-Nr. DE93889386 GHM GROUP - Greisinger GHM Messtechnik GmbH | Hans-Sachs-Str. 26 | 93128 Regenstauf | GERMANY Tel.: +49 9402 9383-0 | info@greisinger.de | www.greisinger.de...
E42.X.1X.6C-02 Operating Manual GIA 0420 N / GIA 010 N page 2 of 10 Index DESIGNATED USE ..............................2 GENERAL NOTE ..............................2 SAFETY REQUIREMENTS ............................3 ............................ 3 ENERAL SAFETY ADVICES ............................3 KILLED ERSONNEL DISPOSAL NOTES ..............................3 ELECTRIC CONNECTION ............................
E42.X.1X.6C-02 Operating Manual GIA 0420 N / GIA 010 N page 3 of 10 Safety Requirements 3.1 General safety advices This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device.
E42.X.1X.6C-02 Operating Manual GIA 0420 N / GIA 010 N page 4 of 10 Electric connection The GIA ... N is connected via screw-type/plug-in terminals on the rear side. General Note: Screw-type/plug-in terminals have to be mounted while they are still loose and plug them in only afterwards.
E42.X.1X.6C-02 Operating Manual GIA 0420 N / GIA 010 N page 5 of 10 Configuration Note: The device can be ESD sensitive at the area of the buttons. The configuration must be done considering adequate ESD safety measures! Please note: measuring current should be at least 4 mA during configuration of a GIA 0420 N! Follow these instructions to configure the device: ...
Page 6
E42.X.1X.6C-02 Operating Manual GIA 0420 N / GIA 010 N page 6 of 10 OVTP Output function No output, device used as display 2-point-controller AL.F 1 Min- / max- alarm, together Depending on the selected output function further parameters have to be adjusted. The configuration menu automati- cally skips parameters not needed for the selected output function.
E42.X.1X.6C-02 Operating Manual GIA 0420 N / GIA 010 N page 7 of 10 Selection of switching and alarm points Note: The device can be ESD sensitive at the area of the buttons. The configuration must be done considering adequate ESD safety measures! Note: All relevant switching and alarm points can be set at this menu.
E42.X.1X.6C-02 Operating Manual GIA 0420 N / GIA 010 N page 8 of 10 Offset and slope adjustment Note: The device can be ESD sensitive at the area of the buttons. The configuration must be done considering adequate ESD safety measures! The offset and slope-adjustment function can be used for compensating the tolerance of the used sensor, resp.
E42.X.1X.6C-02 Operating Manual GIA 0420 N / GIA 010 N page 9 of 10 10 Error Codes When detecting an operating state which is not permissible, the device will display an error code. The following error codes are defined: Err.1: Exceeding of measuring range Indicates that the valid measuring range of the device has been exceeded.
E42.X.1X.6C-02 Operating Manual GIA 0420 N / GIA 010 N page 10 of 10 11 Specifications GIA 0420 … GIA 010 … Input signal: 4 ... 20 mA (2-wire) 0 ... 10 V (3-wire) 3.0 – 3.5 V Voltage load: (typ.) Input resistance: approx.