Functions - ABB RELION 630 Series Applications Manual

Generator protection and control
Hide thumbs Also See for RELION 630 Series:
Table of Contents

Advertisement

Section 3
REG630 variants
3.2.2
3I
3U
Io
∆Io
3I
Io
GUID-73E671D3-F46A-4778-8A7E-03AAED8AAACA V1 EN
Figure 8:
Functionality overview for preconfiguration A
26

Functions

REG630
GENERATOR PROTECTION AND CONTROL IED
For directly connected generator set
PROTECTION
I→O
94
P>
P<
X<
32R/32O
32U
40
3Ith>T/G
I(U)>
49T/G
51V
3dl>G/M
87G/87M
1× 1×
I2>G/M
3I>/Io>BF
51BF/51NBF
46G/46M
3I>
3I>>
51P-1
51P-2
1× 1×
Io>→
Io>→
67N-1
67N-2
Uo
2× 1×
3U<
3U>
Uo>
27
59
59G
df/dt>
f<
81R
81U
Z<GT
U/f>
dUo(3H)>/Uo(3H)<
21GT
24
27/59THD
U<RT
Q>→, 3U<
27RT
32Q, 27
U1>
U1<
Io>>>
47O+
47U+
50N/51N
Io>
Io>>
Io>R
51N-1
51N-2
64R
3I>>→
3I2f>
VS
67-2
68
78V
3dlHi>G/M
dIoHi>
87GH/87MH
87NH
16×
MAP
MAP
LOCAL HMI *
)
*
Fixed or detached LHMI is available.
)
CONDITION MONITORING
3I
AND SUPERVISION
1× 1×
FUSEF
CBCM
60
CBCM
MCS 3I
OPTS
MCS 3I
OPTM
U<>
U<>
CONTROL AND INDICATION
Object
CB
DC
ES
Check availability of binary inputs/outputs
1)
from technical documentation
f>
2)
Control and indication function for
81O
primary object
SYNC
25
U2>
47O-
3I>>>
50P/51P
3I>→
67-1
REMARKS
Optional
3dI>T
function
87T
Function(s) not enabled by
default in preconfiguration,
can be enabled afterwards
1MRS757582 C
PRE-
CONFIGURATION
ALSO AVAILABLE
- 5 × prog. push buttons on LHMI
- Disturbance and fault recorders
- IED self-supervision
- Local/Remote push button on LHMI
- Sequence event recorder
- User management
- WebHMI
COMMUNICATION
Protocols:
IEC 61850-8-1
E
IEC 60870-5-103
E
DNP3
Interfaces:
2× 1×
Ethernet: TX (RJ45), FX (LC)
TCS
Serial:
Serial glass fiber (ST),
TCM
Serial plastic fiber
(snap-in connector)
1)
MEASUREMENT
- I, U, Io, Uo, P, Q, E, pf, f
Ctrl
2)
- Sequence current/voltage measurement
2
- Limit value supervision
- RTD/mA measurement (optional)
8
Analog interface types
Current transformer
Voltage transformer
No. of instances
enabled by default
No. of instances not enabled
by default in preconfiguration,
can be enabled afterwards
Application Manual
A
AND
OR
1 0 1 0 0 0 1 1 0 0 1 1 0 0
1 0 1 1 0 0 1 0 1 1 1 0 0 1 0
1 1 0 0 1 1 1 0 1 1 0 1 0
1 0 1 1 0 1 1 0 1 1 0 1 0 0
1 0 1 0 0 0 1 1 0 0 1 1 0 0 1 0 1 0 0 0 1 1 0
1 0 1 1 0 0 1 0 1 1 1 0 0 1 0
1 1 0 0 1 1 1 0 1 1 0 1 0
1 0 1 1 0 1 1 0 1 1 0 1 0 0
B
7
3
Calculated
value
Io/Uo
REG630