ADVA NTAG ES
Acid resistant material
Operates up to 60 °C and up to 70 °C on
request
Self-protection against damage caused by
dry running
Hose clips/handles
Suitable for small and medium heat
exchangers
Wheels are optional if required
Easy removable tank
B E NE F IT S
Restores the optimal heat exchange
Reduces energy consumption and lower bills
Extends the heating sustem's life
BO S S 36 - BO SS 36 F I
D e s cal i n g pu mp f o r bo i l e rs , hea t
exc h an g e rs , co ol i n g s ys t e ms , pl a -
s t i c p re s s mo ul di n g ma ch in e s , ev a -
po ra t ive t o w e rs , w a l l- mo u nt ed a nd
f l oo r- s t an di ng boi l e rs .
C O D. 30 0 60 1 0 08
F I - CO D. 30 0 6 01 0 07
T EC H NI C AL FE AT URE S
TANK
MAX FLOW RATE
CONNECTIONS
MOTOR
230 V/50 Hz/0,29 kW
PRESSURE
DEGREE OF PROTECTION
WEIGHT
MAX TEMPERATURE
DIMENSIONS
PAC K AG I N G FE AT URE S
NUMBER OF PIECES PER BOX
N. OF PCS PER EPAL PALLET
BOX DIMENSIONS
EPAL PALLET DIMENSIONS
PRODUCT WEIGHT
BOX WEIGHT
EPAL WEIGHT
CUSTOMS CODE *
BARCODE EAN 13
*Data updated in May 2016
M A I N F E AT UR E S
mps BO
Descaling pu
the most suitable device for the descale of wall-
hung boilers, boilers, water heaters and coils
obstructed by limestone. It is characterized by
an excellent manageability, high prevalence and
flow rate, safety of use and easy maintenance to
guarantee the highest results and speed of in-
tervention. It is completely made with anti-acid
material, except for the motor with vertical axis,
properly protected with an anti-acid shrinkable
membrane. The motor is assembled on a strong
lid on the tank closure, completely unscrewing
and removable, to guarantee an extremely easy
maintenance. Equipped with Flow Inverter (FI)
that guarantees to the descaling liquid to alter-
natively act at both side of the circuit. The use
of descaling products with inhibitors, created by
Manta Ecologica S.r.l. assure a fast intervention
and the maximum safety for heating systems
and workers.
Boss 36 FI
36 l
48 l/min
3/4"
230 V/50 Hz/0,29 kW
1,5 bar
IP 55
11 kg
60° C
H: 630 mm
H: 630 mm
L: 350 mm
L: 350 mm
P: 350 mm
P: 350 mm
Boss 36 FI
1 pc
18
H: 67 L: 37 P: 37,5 cm
H: 67 L: 37 P: 37,5 cm
80x120x214 cm
80x120x214 cm
11 kg
12,5 kg
245 kg
8413.82.00
8054633849774
8054633849767
SS 36 and BOSS 36 FI
Boss 36
36 l
68 l/min
3/4"
1,6 bar
IP 55
11 kg
60° C
Boss 36
1 pc
18
11 kg
12,5 kg
245 kg
8413.82.00
are

Advertisement

loading
Need help?

Need help?

Do you have a question about the Boiler Performance BOSS 36 and is the answer not in the manual?

Questions and answers

Summary of Contents for Manta Boiler Performance BOSS 36

  • Page 1 • Extends the heating sustem’s life natively act at both side of the circuit. The use of descaling products with inhibitors, created by Manta Ecologica S.r.l. assure a fast intervention and the maximum safety for heating systems and workers.
  • Page 2 Thanks to the possibility of unscrewing and screw- ing the pump in 10” and without any tools, Manta is the only manufacturing company, that guaran- tees to be in the working place with both acid solution and neutralizing solution ready for the rapid use.
  • Page 3 (directional valve) to obtain a better result. In case of excessive foam production, dilute the acid solution and switch off for a short time the pump. At the end of the descaling operation, replace the acid solution inside the pump, with clean water and rinse the descaled element.
  • Page 4 62321-4:2013, IEC 62321-6:2015, IEC 62321-7-1:2015, IEC 62321-7-2:2017, EN 50564:2011. O R IGI N OF TH E P RO DU C T Made in Italy P.S.345_Boss 36_20191018 Boiler Performance by Manta Ecologica s.r.l. Viale Archimede, 45 – 37059 Zevio (VR) Italy www.mantaecologica.com – Tel.: +39 045 8731511...

This manual is also suitable for:

Boiler perfomance boss 36 fi