ZIEHL-ABEGG NETcon D-G-64NE Operating Instructions Manual

ZIEHL-ABEGG NETcon D-G-64NE Operating Instructions Manual

Gateway profinet-modbus

Advertisement

Quick Links

english
NETcon
D-G-64NE
Part.-No.: 380102
Gateway PROFINET-MODBUS
Operating Instructions
L-BAL-E273-GB 1631 Index 001
Part.-No.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NETcon D-G-64NE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZIEHL-ABEGG NETcon D-G-64NE

  • Page 1 english NETcon D-G-64NE Part.-No.: 380102 Gateway PROFINET-MODBUS Operating Instructions L-BAL-E273-GB 1631 Index 001 Part.-No.
  • Page 2: Table Of Contents

    Operating Instructions NETcon D-G-64NE Content General notes ..........
  • Page 3 Operating Instructions NETcon D-G-64NE Process data ........
  • Page 4: General Notes

    We do not accept any liability for possible errors or omissions in the information con- tained in data, illustrations or drawings provided. ZIEHL-ABEGG SE is not liable for damage due to misuse, incorrect use, improper use or as a consequence of unauthorized repairs or modifications.
  • Page 5: Intended Use

    Operating Instructions NETcon D-G-64NE Safety instructions 2.1 Intended use The equipment is to be used solely for the purposes specified and confirmed in the order. Any other use above and beyond this is considered not for the intended purpose unless agreed otherwise by contract.
  • Page 6: Start-Up And During Operation

    ZIEHL-ABEGG.These parts were specifically designed for the device. There is no guarantee that parts from non-original sources are designed and manufactured in correspondence with load and safety requirements. Parts and optional equipment not supplied by ZIEHL-ABEGG are not approved by ZIEHL-ABEGG for use. L-BAL-E273-GB 1631 Index 001 Part.-No.
  • Page 7: Operator's Obligation Of Diligence

    Operating Instructions NETcon D-G-64NE Product overview 2.8 Operator’s obligation of diligence • The contractor or owner must also ensure that the electric systems and equipment are operated and maintained in accordance with electro-technical regulations. • The owner is obliged to ensure that the device is operated in perfect working order only.
  • Page 8: Maintenance

    Operating Instructions NETcon D-G-64NE Mounting 3.3 Maintenance The device must be checked for soiling and, if necessary, cleaned in periodic intervals. 3.4 Transport • The device is packed ex factory to suit the transport method previously agreed. • Always use the original packaging materials when transporting the device.
  • Page 9: Temperature Influences During Commissioning

    Operating Instructions NETcon D-G-64NE Electrical installation 4.2 Temperature influences during commissioning Avoid condensation in the controller and functional faults attributable to condensation by storing the controller at room temperature! 5 Electrical installation 5.1 Safety precautions Danger due to electric current •...
  • Page 10: Voltage Supply

    Operating Instructions NETcon D-G-64NE Electrical installation 5.2 Voltage supply The supply voltage ( Technical Data) is connected at the terminals “V+in” and “V-in” by a 2-pole "MSTB 2.5/2-ST" jumper from Phoenix Contact. Make sure that the supply voltage lies within the allowable tolerance specifications ( Technical data and the nameplate is fixed to the side of the device).
  • Page 11 Operating Instructions NETcon D-G-64NE Electrical installation network status Explanation Switched off Green Operation Green Stopped Flashes once Green Identification flashing Error Name of station not set Flashes once IP address not set Flashes twice Configuration error Flashes three times port2: l/a/s...
  • Page 12: Communication

    If there is any doubt about the use or procurement of the GSD file for this add-on module, our Support department will be glad to help you (see Service information). The GSD file for AM-PROFINET has the name “GSDML-V2.32-ZIEHL-ABEGG-AM- PROFINET-20160520.xml”...
  • Page 13: Process Data

    Operating Instructions NETcon D-G-64NE Communication 6.3 Process data Test Tool e.g. PROFINET MASTER SIMULATOR from HMS. Configuration It is an encapsulated packet, 10 receive bytes and 10 output bytes. You can read and write the register data. Frame Byte Head...
  • Page 14: Supported Commands

    Operating Instructions NETcon D-G-64NE Communication IO data 6.3.1 Supported commands • 1 - Read Coils • 3 - Read Holding Register • 4 - Read Input Registers • 5 - Write Single Coil Registers • 6 - Write Single Holding Registers •...
  • Page 15: Read Data

    Operating Instructions NETcon D-G-64NE Communication 6.4 Read data Read Holding Register (3) / Read Input Register (4) Request data Frame Byte Value Description Remarks Head 0x18 Meter Runs automatically continuously from 0x01...0xFF, e.g. 0x18 0x06 Length "6" for reading data...
  • Page 16: Write Data

    Operating Instructions NETcon D-G-64NE Communication 6.5 Write data Write Single Holding Register Query data / received reply Frame Byte Value Description Remarks Head 0x4D Meter Runs automatically continuously from 0x01...0xFF, e.g. 0x4D 0x06 Length "6" for reading data MODBUS 0xF7...
  • Page 17: Example For Setting Of An Ecblue

    Operating Instructions NETcon D-G-64NE Communication 6.6 Example for setting of an ECblue Byte (1) Dummy (2) Accessle- (3) D1 Off (4) Control- (5)Target mode speed value 0x01 0x02 0x03 0x04 0x05 0x00 0x06 0x06 0x06 0x06 0x00 0xF7 (=247) 0xF7 (=247)
  • Page 18: Communication With Ecblue Fans

    Operating Instructions NETcon D-G-64NE Communication 6.7 Communication with ECblue fans Information • All examples in this chapter were handled with the MODBUS address 1 • All data with the prefix“0x” are hexadecimal. Example: 0xC8 means C8 hexadecimal and this corresponds to 200 decimal.
  • Page 19: Write Data

    Operating Instructions NETcon D-G-64NE Communication 6.7.2 Write data Write Single Holding Register Query data / received reply Frame Byte Value Description Remarks Head 0x04 Meter Runs automatically continuously from (query) 0x01...0xFF, e.g. 0x4 and 0x08 0x08 (reply) 0x06 Length "6" for reading data...
  • Page 20: Example For Setting Of An Ecblue

    Operating Instructions NETcon D-G-64NE Communication Information For the "Write Double Holding Register" command note whether the Slave MODBUS devices (e.g. AM-MODBUS) support the command. 6.7.3 Example for setting of an ECblue Byte (1) Dummy (2) Accessle- (3) D1 Off (4) Control-...
  • Page 21: Autoaddressing Of The Modbus-Slaves

    6.7.5 Autoaddressing of the MODBUS-Slaves There are three pre-defined commands to the MODBUS slaves for the autoaddressing. Information The autoaddressing is only possible with ZIEHL-ABEGG ECblue motors and frequency converters with built-in AM-MODBUS modules. 1st phase – initialise addressing mode...
  • Page 22 Operating Instructions NETcon D-G-64NE Communication Query data / received reply Frame Byte Value Description Remarks 0002 Option value (Lo) 0x00 Data value (Hi) Data value 0x01 Data value (Lo) Query data / received reply Frame Byte Value Description Remarks Head...
  • Page 23: Error Byte

    Operating Instructions NETcon D-G-64NE Communication Information The addressing runs until the last device (max. number of devices is 64) is re-addressed. The byte fort he device address (to address the device, byte no. 3) is consecutive and is assigned fixed by the command in phase 1.
  • Page 24: Enclosure

    Operating Instructions NETcon D-G-64NE Enclosure 7 Enclosure 7.1 Technical data Voltage supply 24 V DC +/- 4 V 100 mA (Phoenix 2-pole) • PROFINET Interfaces – 2 x RJ45 • MODBUS – 1 x RS-485 (8-pole connector and RJ45, unshielded)
  • Page 25: Connection Diagram

    Operating Instructions NETcon D-G-64NE Enclosure 7.2 Connection diagram ECblue MODBUS ECblue MODBUS 3...64 MODBUS MODBUS MODBUS MODBUS (RS-485) (RS-485) (RS-485) (RS-485) ID1 GND ID1 GND (D+) (D-) (D+) (D-) (D+) (D-) (D+) (D-) RJ45 RJ45 RJ45 (D+) (D-) Pin 4 B...
  • Page 26: Dimensions [Mm]

    Operating Instructions NETcon D-G-64NE Enclosure 7.3 Dimensions [mm] GM00028A 04.08.2016 L-BAL-E273-GB 1631 Index 001 Part.-No. 26/27...
  • Page 27: Manufacturer Reference

    Operating Instructions NETcon D-G-64NE Enclosure 7.4 Manufacturer reference Our products are manufactured in accordance with the relevant international regulations. If you have any questions concerning the use of our products or plan special uses, please contact: ZIEHL-ABEGG SE Heinz-Ziehl-Straße 74653 Künzelsau...

Table of Contents