Specifications; Maintenance And Inspection - BQT COBALT-mini V1.5 Installation And Operating Instructions Manual

Electronic side load lock
Table of Contents

Advertisement

8. SPECIFICATIONS

MATERIALS
Bolt Pin
Lock / Strike Plate
MECHANICAL
Cycle Life
Maximum Strike Gap
Holding Force
Side Load Release
Door Misalignment
ELECTRICAL
Voltage at Lock
Initial Power Up Time
Current Usage
Monitor Switches
CERTIFICATIONS
FCC
Fire Test
CE / EU
*The product meets the requirements of class 3 for position 9 "Security – Electrical Manipulation" when set to "Fail Secure" mode, and only meets the requirements for class 1 when set to "Fail Safe" mode.

9. MAINTENANCE AND INSPECTION

The Cobalt-mini has been lubricated at assembly and applying any other type of lubricant may void the warranty. A
dry cloth can be used to polish the stainless steel face plate and strike plate as required. This lock contains
components that are subject to wear based on usage, doorway operation and installation; all such factors are beyond
the control and measurement of the manufacturer. The lock may be vulnerable and subject to failure as a
consequence of wear and as its components near the end of the period of normal usage.
It is the responsibility of the owner/end-user to:
a) Ensure that the lock is installed in accordance with the instructions set out in these guidelines.
b) Determine the suitability of this lock for the application intended and in particular when using this lock in
critical applications such as on fire, high security, safety, or emergency exit doors.
c) Regularly inspect this lock in order to assess signs of wear and tear, and determine if the operation still
conforms to the instructions set out in these guidelines.
d) Regularly inspect the lock and evaluate cycle life.
e) Determine when this lock should be replaced.
Page 12
Stainless Steel (SS17-4PH), 10mm Thick, 13mm Extension
Stainless Steel (SS304), 3mm Thick
300,000 normal operations
6mm
10,000 newtons (1,000kg)
1,000 newtons (100kg)
8mm
12 – 24VDC ±15%
11 seconds max, only after power has been removed for an extended period.
Standby Current
Maximum Current
Bolt Position – 30VDC, 0.1A
Door Position – 100VDC, 0.5A
Title 47, Part 15, Subparts A & B – Class B Device
Fire Rated for 30 / 60 minutes
Timber / mineral composite doorsets
Fire Rated for 120 / 240 minutes
Mineral E-Core doorsets
Fire Rated for 260 minutes
Steel doorsets
CPR 305/2011
EMC 2014/30/EU
RoHS 2011/65/EU
50mA@12V
30mA@24V
1.0A@12V
0.5A@24V
BS EN 1634-1:2014
BS 476-22:1987
AS 1905-1:2005
BS 476-22:1987
EN 1634-1:2014
BS EN 1634-1:2014
EN 14846:2008
3
Y
9
F
0
0
EN 61000-6-1:2007
EN 61000-6-3:2007+A1:2011
RoHS 2 Compliant
0
1
1/3*
MP001408.003

Advertisement

Table of Contents
loading

Table of Contents