DZG Metering DVSBR Series Product Manual

Three phase electronic electricity meter

Advertisement

Quick Links

DVSBR Product Manual
Date
Last changes
DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg
Three Phase Electronic Electricity Meter
Version RLM
17.02.2017
25.02.2019
DVSBR
19
Feb

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVSBR Series and is the answer not in the manual?

Questions and answers

Summary of Contents for DZG Metering DVSBR Series

  • Page 1 DVSBR Product Manual Three Phase Electronic Electricity Meter DVSBR Version RLM Date 17.02.2017 Last changes 25.02.2019 DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg...
  • Page 2 The contents of this user manual are copyright reserved. Translations, prints and copies are only allowed authorized by DZG. All mentioned brand names and product names are ownership of DZG Metering GmbH. Contents may be completed, changed or deleted without prior announcements.
  • Page 3 „Notice“ indicates important information in the manual. The symbol is printed on the nameplate and references to further information in an instruction manual prepared for the customer. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019...
  • Page 4: Table Of Contents

    Energy registers ......................... 26 12.3 Basic parameter ......................... 26 12.4 Status word ......................... 28 Accuracy test ..........................29 Manufacturing ..........................29 Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 4 / 29...
  • Page 5 Figure 11 LMN-interface jack assignment ..................17 Figure 12 Block diagram ........................18 Figure 13 Firmware structure ......................23 Figure 14 Firmware flow-diagram..................... 24 Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 5 / 29...
  • Page 6 Time Of Use Tariff (z.B. T1 Tariff 1, T2 Tariff 2, ...) Association of Elektrotechnic/Electronic/Information technic e.V. yyyy Year Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 6 / 29...
  • Page 7: Properties

    Optical interface Infrared, 9600 Bd, 8-N-1, SML RS485; 921.600 bps, 8N1 (default), according 4 LMN interface RJ12 female connector Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 7 / 29...
  • Page 8: Technical Standards

    [3] WELMEC-Guide 7.2, software guide 4 FNN-Hinweis „Lastenheft Basiszähler Funktionale Merkmale“, Version 1.3, 25.11.2016 FNN FORUM NETZTECHNIK/NETZBETRIEB IM VDE Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 8 / 29...
  • Page 9: Safety

    Damaged devices can’t be repaired by yourself. The warranty and liability will be terminated with opening the device. The same applies to damages caused by external influences. For the device no servicing is required. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019...
  • Page 10: Typecode

    Product Manual DVSBR Typecode Table 2 Typecode Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 10 / 29...
  • Page 11: Assembling And Installation

    Two sealing screws Conforms to DIN 43854 Material: Steel(SAE 1018) Terminal screws Conform to ISO-4757-1938 Table 4 Housing materials Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 11 / 29...
  • Page 12: Table 5 Terminal Block

    Table 5 Terminal block Attention! Additional equipment may only be supplied from the uncounted range of the meter. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 12 / 29...
  • Page 13: Installation

    0.5 A. Devices connected via the additional voltage terminals must be protected by their own internal switches. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019...
  • Page 14: Protection Housing

    The installation space cover and the meter cover have preparations for attaching the user seals (page 10, Fig.1) Figure 7 User sealing Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019...
  • Page 15: Nameplates

    Ownership endorsement section Measurement mode Protection class Connection Type code e.g. DVSBR20.5TH Table 7 Nameplate elements Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 15 / 29...
  • Page 16: Lcd-Display

    The type of output can be changed under the menu item Device parameters. No load: LED on On load: LED on for 2ms Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019...
  • Page 17: Communication Interfaces

    The interface is always supplied by the SMGw. The power consumption is max. 3W. For use without SMGw, the interface is supplied internally. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG...
  • Page 18: Behavior Of External Interfaces

    It then integrates these power units till a preset quantity has been used. The consumption of this packets of power is very small. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG...
  • Page 19: Functionality

    3 if these are activated. If the tariff function is disabled o the energy counting is done in x.8.0 and x.8.1 Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019...
  • Page 20: Table 9Tariff Control Modes

    In addition, the LMN interface can be used to configure whether the totalizer for T2 or T1 is switched on via "true". The tariff function can only be deactivated again via the LMN interface Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019...
  • Page 21 The configuration of the tariff control leads to the following behavior for the display and the output in the data set via the optical interface: Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG...
  • Page 22: User Interface (Display, User Key)

    Each value in the upper row is displayed for 10s. In case of a fatal error, F.F FFFFFF is shown in the display for 2 s between the values. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG...
  • Page 23: Firmware

    LED. The meter application contents the meter specific function which complies to the requirements of the FNN specifications 4. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019...
  • Page 24 There is timeout definition for each function block. If there is no normal operation for any part more than timeout duration, this part will be reset by system. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG...
  • Page 25: Fatal Error

    Phase angle I-L1 to U-L1 1-0:81.7.15*255 Phase angle I-L2 to U-L2 1-0:81.7.26*255 Phase angle I-L3 to U-L3 Table 10 Instantaneous data Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 25 / 29...
  • Page 26: Energy Registers

    ‘0’. The last valid condition is restored when the voltage supply is reconnected. Value range: TRUE/FALSE Default value: FALSE Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 26 / 29...
  • Page 27 MM1 = 0x08, 0x01, 0x01, 0x60, MM2 = 0x0A, R/W(M) 0x60, 0x04, 0xFF MM3 = 0x02, MM4 = 0x01, Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 27 / 29...
  • Page 28: Status Word

    0/1 = off/ on voltage L2 0/1 = off/ on voltage L3 21-31 reserved Table 13 Status word Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG 2/25/2019 Page 28 / 29...
  • Page 29: Accuracy Test

    9001 and is the responsible body for the state-approved testing laboratory for electricity meters EBB1. The processes, controls and documentations are organized according to the quality standard. Copyright  DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg Copies only are allowed authorized by DZG...