Download Print this page

Xi an ZFE ZF190 Operating Instructions Manual

Intelligent gateway device

Advertisement

Quick Links

Intelligent Gateway Device
ZF190
Operating Instructions
V1.0.0
Xi'an ZFE Technology Co., Ltd.

Advertisement

loading

Summary of Contents for Xi an ZFE ZF190

  • Page 1 Intelligent Gateway Device ZF190 Operating Instructions V1.0.0 Xi’an ZFE Technology Co., Ltd.
  • Page 2 Statement All rights reserved, without the written permission of the company, the contents of any paragraph in this manual shall not be extracted, copied or reproduced or transmitted in any form, otherwise all consequences will be made by the offender. The company reserves the right to modify the product specifications described in this manual without prior notice.Before ordering, please contact the factory for the latest specifications of this product.
  • Page 3: Table Of Contents

    ® 兆孚 XI’AN ZFE TECHNOLOGY CO.,LTD 029-88469134 www.xaZFE.com Table of Contents 1、Introduction ..........................1 2、System structure diagram ......................1 3. Technical characteristics ....................... 2 4、Interface description and function description ................2 5、Technical Parameters ........................4 6. Web browser parameter settings ....................6 7、Dimensions (147mm×103mm×42mm) ..................
  • Page 4: 1、Introduction

    1、Introduction The intelligent gateway device ZF190 is a product that specializes in the application of remote data reading and file transfer. It reads data from terminal devices such as data collectors and sensors locally, and communicates via RS485 or CAN. Read data from the DTU device. After the reading is completed, the data of the DTU device is periodically stored in the internal SD to store the history of the device.
  • Page 5: Technical Characteristics

    ® 兆孚 XI’AN ZFE TECHNOLOGY CO.,LTD 029-88469134 www.xaZFE.com (3)The gateway transmits data to the FTP server through the network. 3. Technical characteristics High performance, low power consumption, high reliability with NXP (formerly Freescale) i.MX 6UltraLite processor。 ●All components of the core module reach the industrial temperature range of -40 to 85 °C ●...
  • Page 6 ® 兆孚 XI’AN ZFE TECHNOLOGY CO.,LTD 029-88469134 www.xaZFE.com of each terminal is identified by the character above the terminal. For example: A1 and B1 represent A and B of the first RS-485 interface, respectively, and L1 and H1 represent L and H of the first CAN interface, respectively.
  • Page 7: 5、Technical Parameters

    ® 兆孚 XI’AN ZFE TECHNOLOGY CO.,LTD 029-88469134 www.xaZFE.com (7) 5-digit 3.81mm pitch green terminal is a card reader module interface, providing one RS-232 three-wire serial port, 5V and 12V power supply (8) 1 standard RJ-45 network cable interface, adaptive 10M/100M Ethernet. (9) The lower right corner is the LVDS interface.
  • Page 8 ® 兆孚 XI’AN ZFE TECHNOLOGY CO.,LTD 029-88469134 www.xaZFE.com 512MB LvDDR3 FLASH e.MMC 或 NandFlash,The four boot configuration jumpers of the backplane must be set according to the type of the core board. External storage Standard SD card interface, support SD, SDHC, SDXC card, the maximum measured capacity is 64G SDXC card Mobile communication SIM800A module with drawer type Mini SIM card slot ("SIM-GPRS"...
  • Page 9: Web Browser Parameter Settings

    ® 兆孚 XI’AN ZFE TECHNOLOGY CO.,LTD 029-88469134 www.xaZFE.com Power and power Rated voltage: 12V, can work normally in the range of 9V-15V, with reverse connection consumption protection; Total power consumption is less than 5W when equipped with TopView LMT070DICFWD-AKA 147mm×103mm×42mm size installation 4 Φ4mm screws working...
  • Page 10 (1) Reset Device Reboot the ZF190 Device (2) Modbus File Download: Browse the modbus config file and submit to modify the modbus config of ZF190. (3) Telecommunications operators: APN(Access Point Name): Telecom operators APN (4) FTP Settings: HOST: FTP Server IP address...
  • Page 11 ® 兆孚 XI’AN ZFE TECHNOLOGY CO.,LTD 029-88469134 www.xaZFE.com (5) COM1 Port Settings: BAUD: 485 bus baud rate DATABITS/PARITY/STOPBITS: Data bit/parity/stop bit SCHEDULE: Gateway and meter communication handshake interval PATH: File node mounted by the device on the gateway operating system (6) COM2 Port Settings: BAUD: 485 bus baud rate DATABITS/PARITY/STOPBITS: Data bit/parity/stop bit...
  • Page 12 DATA ACQUISITION INTERVAL(MINS): Data acquisition interval (unit: minute) DATA REPORT INTERVAL(HOURS): CSV data storage interval (unit: hour) (8) LAN IP Settings: IP Address: Local IP Address of ZF190 Subnet Mask: Subnet Mask of ZF190 (9) Product ID Settings: Product ID: Product ID of this Device...
  • Page 13: 7、Dimensions (147Mm×103Mm×42Mm)

    ® 兆孚 XI’AN ZFE TECHNOLOGY CO.,LTD 029-88469134 www.xaZFE.com 7、Dimensions (147mm×103mm×42mm) 4 Φ4mm screws Positioning hole position: 47mm*135mm...
  • Page 14 ® 兆孚 XI’AN ZFE TECHNOLOGY CO.,LTD 029-88469134 www.xaZFE.com 西安兆孚电气科技股份有限公司 XI’AN ZFE TECHNOLOGY CO.,LTD Addr:Fengze Science and Technology Park, 170 West Avenue, High-tech Zone, Xi'an Zip code:710000 Tel:029-88469134 Fax:029-88469134 Web:www.xazfe.com Email:sale@xazfe.com...