SEA USA USER 1 24V DG R1 Manual

24v electronic control unit for sliding gates and barriers

Advertisement

Quick Links

International registered trademark n. 2.777.971
USER 1 - 24V DG R1
24V
ELECTRONIC CONTROL UNIT FOR SLIDING GATES AND BARRIERS
SEA USA Inc.
10850 N.W. 21st unit 160 DORAL MIAMI
Florida (FL) 33172 USA
Tel.
:++1-305.594.1151 ++1-305.594.7325
-
Toll free:
800.689.4716
web site: www.sea-usa.com
e-mail: sales@sea-usa.com
67411535
REV 07 - 06/2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the USER 1 24V DG R1 and is the answer not in the manual?

Questions and answers

Summary of Contents for SEA USA USER 1 24V DG R1

  • Page 1 International registered trademark n. 2.777.971 USER 1 - 24V DG R1 ELECTRONIC CONTROL UNIT FOR SLIDING GATES AND BARRIERS SEA USA Inc. 10850 N.W. 21st unit 160 DORAL MIAMI Florida (FL) 33172 USA Tel. :++1-305.594.1151 ++1-305.594.7325 Toll free: 800.689.4716 web site: www.sea-usa.com e-mail: sales@sea-usa.com...
  • Page 2 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 Details General An appliance shall be provided with an instruction manual. The instruction manual shall give instructions for the installation, operation, and user maintenance of the appliance. The installation instructions shall specify the need for a grounding-type receptacle for connection to the supply and shall stress the importance of proper grounding.
  • Page 3 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 g) The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start. h) A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible. i) For gate operators utilizing a non-contact sensor: 1) See instructions on the placement of non-contact sensors for each Type of application, 2) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is...
  • Page 4: Description Of The Components

    USER 1 - 24V DG R1 International registered trademark n. 2.777.971 DESCRIPTION OF THE COMPONENTS TECHNICAL SPECIFICATIONS Control unit power supply 24 V~ Absorption in stand by 30 mA Environment temperature : -20 -4°F +122°F) Specifications of external enclosure 305 x 225 x 125 mm (12 x 9 x 5 inches) - Ip55 LIGHT FUSE POWER...
  • Page 5 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 CONNECTIONS POWER (CN8) MOTOR (CN6) LIGHT (CN5) 24V~ Max 200W Max 100mA 9 10 11 12 13 ANT COM START PEDST STOP COM PH1 PH2 EDGE AUX COM 24V (FL)- JUMPERS WARNING: The control unit is designed with the automatic detection of not used N.C.
  • Page 6 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 PROGRAMMING QUICK START PROGRAMMING BUTTONS MENU MENU LANGUAGE ITALIANO DOWN Skip this step if you do not want to program a transmitter OK to exit Press the Menu or press MENU MENU MENU...
  • Page 7 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 MENU FUNCTIONS TABLE USER1 24V DG R1 MENU Description Default Set value tal ano Italian engl sk English 1 - langvage tal ano fran(a s French espanol Spanish dut(k Dutch start Start...
  • Page 8: Function Logic

    USER 1 - 24V DG R1 International registered trademark n. 2.777.971 WORKING TIMES SELF LEARNING NOTE: When using a B200 motor or magnetic limit switches in general; make sure that the control unit is set on magnetic limit switch before learning. MENU 34 - TYPE OF Li i T SUiT(X - AGNETI( 1) Disconnect the power supply, release the motor (Fig.
  • Page 9: Special Menu

    PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU DOWN SPECIAL MENU FUNCTIONS TABLE USER 1 24V DG R1 For entering into the special menu move on one of the menu and press the UP and DOWN buttons at the same time for 5 s.
  • Page 10 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 MENU SP Description Default Set Value Disabled Timer function active ON PXOTO2 17 - t on photocell 2 Timer function active on ON PEDESTR AN ENTRY pedestrian input Nor al Normal N.C.
  • Page 11 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 MENU SP Description Default Set Value AUX output always ALUAYS power supplied AUX output active only N (Y(LE during cycle AUX output power OPEN NG supplied only during opening AUX output power (LOS NG 21 - 24u avx...
  • Page 12 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 MENU SP Description Default Set Value 10 99 Setting from 10 to 99 31 - (LOS NG SENS T U TY * 10 Disabled 32 - PXOTO off n (LOS NG 0 50 Setting from 0 to 50 For applications with two...
  • Page 13 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 INPUT CHECK MENU The settings of the control unit are made through the UP, DOWN and OK buttons. The UP and DOWN buttons to scroll through the MENUS and SUBMENUS.
  • Page 14 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 RADIO TRANSMITTER SELF LEARNING WITH RECEIVER ON BOARD OF CONTROL UNIT WARNING: Make the radio transmitters programming before you connect the antenna and insert the receiver into the special CMR connector (if available) with turned off control unit. With RF UNI module it will be possible to use both Coccinella Roll Plus transmitters, max.
  • Page 15 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 START - STOP - PEDESTRIAN START - ANTENNA - PHOTOCELL Photocell 1 and Photocell 2 Connections + = 24V (Accessories) max 750mA COM = 0V PH1 = Photocell contact 1 PH2 = Photocell contact 2 Note: For the autotest connect the TX to the AUX clamp and activate the Autotest function.
  • Page 16 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 LIMIT SWITCH AND SENSOR BARRIERS Sensor barriers This control unit comes with a detection device of motor current absorbtion which allows to reveal possible obstacles during the opening and the closing of the gate. When this device intervenes in opening it causes the inversion of the movement for around a second, if it intervenes in closing it causes the total reopening.
  • Page 17: Motor Power Supply

    USER 1 - 24V DG R1 International registered trademark n. 2.777.971 MOTOR POWER SUPPLY TRANSFORMER 115V~ 230V~ 3,6 A blow fuse on 230V ~ power supply 6,3A blow fuse on 115V ~ power supply POWER (CN8) WARNING: K e e p t h e p o w e r Power input c a b l e s ( m o t o r s , p o w e r Input for the connection of the electric...
  • Page 18: Master-Slave Function

    USER 1 - 24V DG R1 International registered trademark n. 2.777.971 MASTER-SLAVE FUNCTION To set an installation with two motors in MASTER-SLAVE function it is recommended to do as follows: 1) Set the two motors as if they were two independent installations, make sure that the individual motor works properly and that the limit switches (when present) are read properly.
  • Page 19 USER 1 - 24V DG R1 International registered trademark n. 2.777.971 CONNECTION OF BATTERIES TO BATTERY CHARGER CARD Specifications of optional batteries: 24V Pb 1.2Ah min. Cod.23101105 = charge 200mA = charge 360mA = charge 800mA GND PSOL BAT 28V Battery charger (BAT) Positive battery...
  • Page 20: Troubleshooting

    Periodically clean the optical systems of the photocells. REPLACEMENTS Any request for spare parts must be sent to: SEA USA Inc. 10850 N.W. 21st unit 160 DORAL MIAMI Florida (FL) 33172 USA Tel. :++1-305.594.1151 ++1-305.594.7325 Toll free: 800.689.4716...
  • Page 21 Products under warranty will be returned pre-paid by SEA. Recognized defects, whatever their nature, will not produce any responsibility and/or damage claims to SEA USA Inc and SEA s.r.l. Warranty shall not cover any required labor activities. Warranty will in no case be recognized if alterations and any other changes will be found on products.
  • Page 24 International registered trademark n. 2.777.971 SEA USA Inc. 10850 N.W. 21st unit 160 DORAL MIAMI Florida (FL) 33172 USA Tel. ++1-305.594.1151 ++1-305.594.7325 Toll free: 800.689.4716 web site: www.sea-usa.com e-mail: sales@sea-usa.com...

Table of Contents