ATTENTION:
BEFORE USING THE DETAIL READ THE INSTRUCTIONS. The exact adherence to these instructions will allow for safe use and will allow you and others
to avoid health damage.

SAFETY RULES:

AND.
In order to avoid mortal danger observe the following rules:
1. strictly follow these instructions to avoid injury or even death.
2. Construction of the input voltage, a suitable location for the device, the pressure of gas used, etc. All the above must be adapted to the relevant provisions.
3. Bystanders should not stay in the place of welding.
4. Persons with pacemakers are not allowed in the vicinity of the weld without the prior consent of the doctor.
5. Installation and repair should be performed only by persons authorized to do so.
6. Working in the rain is not permitted.
7. For safety must be correctly understood the content of the specification.
TO REDUCE THE RISK OF ELECTRIC SHOCK TO FOLLOW THESE RULES:
1. Avoid contact with the welding circuit.
1. Avoid contact with the welding circuit.
2. Carry out electrical installations in accordance with applicable standards and regulations and safety at work.
2. Carry out electrical installations in accordance with applicable standards and regulations and safety at work.
3. Connecting the welding, inspection or repair should be performed after disconnecting the power supply unit.
3. Connecting the welding, inspection or repair should be performed after disconnecting the power supply unit.
4. Do not use cables with damaged insulation work and / or loosened connections.
4. Do not use cables with damaged insulation work and / or loosened connections.
5. Make sure that the power cord is not damaged.
5. Make sure that the power cord is not damaged.
6. Do not use the device when the housing is removed.
6. Do not use the device when the housing is removed.
7. Wear protective gloves
7. Wear protective gloves
8. Do not touch the handle both mass and torch.
8. Do not touch the handle both mass and torch.
9. Never immerse the electrode in water for cooling
9. Never immerse the electrode in water for cooling
10. It is prohibited to welding operators, arranged above the ground, except for possible use cases
10. It is prohibited to welding operators, arranged above the ground, except for possible use cases
Security platforms.
11. Observe deadlines inspection device.
11. Observe deadlines inspection device.
12. Do not use damaged equipment.
12. Do not use damaged equipment.
13. Disconnect the device from the mains when not in use.
13. Disconnect the device from the mains when not in use.
14. The device should be connected only to the installation provided with a grounding wire (PE).
14. The device should be connected only to the installation provided with a grounding wire (PE).
ATTENTION:
In order to avoid starting a fire, explosion, observe the following rules:
Do not weld near flammable materials.
Sparks and hot material can cause fire.
Weld containers or tubes which contain or contain liquid or gaseous combustible substances
Do not work on materials cleaned a chlorinated solvent, and does not store the device in the vicinity
Near the place of work to keep a fire extinguisher
ATTENTION:
In order to avoid tipping cylinder gas explosion or gas regulator should observe the following rules:
(Rolling over of the gas cylinder can cause a fatal accident)
WELDMAN
Inverter welder TIG 200 DC
POWER PULSE HF / LIFT
USER MANUAL
POWER PULSE DC TIG 200 HF / LIFT
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POWER DC TIG 200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Weldman POWER DC TIG 200

  • Page 1: Safety Rules

    Near the place of work to keep a fire extinguisher ATTENTION: In order to avoid tipping cylinder gas explosion or gas regulator should observe the following rules: (Rolling over of the gas cylinder can cause a fatal accident) WELDMAN POWER PULSE DC TIG 200 HF / LIFT...
  • Page 2 PU 3.5 m quick coupling type 21 and two clamps • carrying case made of plastic gas regulator absent standard equipment. gas regulator absent standard equipment. gas regulator absent standard equipment. WELDMAN POWER PULSE DC TIG 200 HF / LIFT...
  • Page 3 III. SPECIFICATIONS WELDERS: III. SPECIFICATIONS WELDERS: MODEL POWER DC TIG 200 GENERAL 230V / 50Hz POWER SUPPLY VOLTAGE POWER PROTECTION 20 A CURRENT CURRENT MAX POWER 28.6 A 36.6 A CURRENT INTENSITY POWER EFF. 14.3 A 20 And VOLTAGE POWER IDLE...
  • Page 4 6) The slot-pin controller 5 (front panel) to connect the plug of the control handle 6) The slot-pin controller 5 (front panel) to connect the plug of the control handle TIG welding (TIG only) WELDMAN POWER PULSE DC TIG 200 HF / LIFT...
  • Page 5 (0-10 sec.) current end - only a 4-stroke (5-200 A) POST function GAS - Time flow of gas after the expiration of the arc (0.1-10 s). enable / disable function TIG PULS WELDMAN POWER PULSE DC TIG 200 HF / LIFT...
  • Page 6 2,0x175 mm 108 804 108 814 108 824 108 834 2,4x175 mm 108 805 108 815 108 825 108 835 3,2x175 mm 108 806 108 816 108 826 108 836 4,0x175 mm WELDMAN POWER PULSE DC TIG 200 HF / LIFT...
  • Page 7 (gas nozzle, the nozzle current) ▪ replace worn or damaged parts of the monthly ▪ maintenance operations: clean the inside of compressed air welder ▪ check the electrical connections inside the welder ▪ WELDMAN POWER PULSE DC TIG 200 HF / LIFT...
  • Page 8 The symbol, which means sorting of waste electrical and electronic equipment. It is forbidden to suppress the equipment as mixed municipal solid waste, the responsibility of the user is directed to an authorized waste collecting centers. WELDMAN POWER PULSE DC TIG 200 HF / LIFT...

Table of Contents