DUAL ACTIVATION FAN RELAY WITH 185
THERMOSTAT INSTALLATION INSTRUCTIONS
This electric fan relay kit has a capacity of 30 Amps and will operate a single or dual fan setup.
The relay will activate the electric fan if the thermostat reaches 200 degrees Fahrenheit or if the
A/C compressor clutch is engaged.
1.
Mount the relay under the hood in a convenient location as close to the fan as
possible. Use the ¾" self tapping hex screw to mount the relay base. The black wire
with the ring terminal preinstalled will also need to be grounded with this terminal.
Make sure the area you mount this provides a clean ground for the black wire.
2.
Install thermostat into a
water jacket in the head or
intake manifold. Unroll the
PINK wire from the parts
kit. Strip ¼" of insulation
from the copper on one end.
Crimp one of the female
spade connectors onto this
wire. Push the spade
connector onto one of the
male spades on the
thermostat. Route the PINK
wire from the thermostat to a
12 Volt ignition hot source.
Cut it to length and use the
blue Posi-tap to make the
connection. To the right is
an illustration of how to use
a Posi-tap.
3.
Route the GRAY/WHITE wire from the relay to the thermostat. Strip ¼" of
insulation from the copper and crimp on the other female spade terminal. Push this
onto the other male spade terminal on the thermostat.
817-244-6212 Phone • 817-244-4024 Fax
888-350-6588 Sales • 800-423-9696 Tech
E-mail: painless@painlessperformance.com
Web:
30115
1
2501 Ludelle Street
Fort Worth, Texas 76105
www.painlessperformance.com
o
o
ON 175
OFF

Advertisement

loading

Summary of Contents for Painless Performance Products 30115

  • Page 1 888-350-6588 Sales • 800-423-9696 Tech E-mail: painless@painlessperformance.com Web: www.painlessperformance.com 30115 DUAL ACTIVATION FAN RELAY WITH 185 ON 175 THERMOSTAT INSTALLATION INSTRUCTIONS This electric fan relay kit has a capacity of 30 Amps and will operate a single or dual fan setup.
  • Page 2 Route the GREEN/WHITE wire to the A/C compressor clutch. Use the yellow Posi- tap to connect this GREEN/WHITE wire to the 12 Volt power wire that activates the A/C compressor clutch. Use the other two self tapping hex head screws to mount the circuit breaker as close as possible to whichever power source (battery or large terminal on the starter solenoid) you are using for the fan relay.
  • Page 4 You must return the product to the dealer you purchased it from to initiate warranty procedures. Copyright © 2008 by Painless Performance Products, LLC...