CST Crydom HDC Series Installation Sheet

CST Crydom HDC Series Installation Sheet

Dc load solid state contactors

Advertisement

Quick Links

HDC Series
DC Load Solid State Contactors
The HDC Series Solid State Contactors (SSCs) are designed for control of high power DC loads
such as brakes, clutches, coils, electro magnets, heaters, lamps, motors, solenoids, etc., where
long life and fast switching are required and traditional mechanical contactors or relays don't
provide the required life, performance or service levels. The HDC Series offers the latest in DC
Solid State Power control by virtue of Crydom's advanced high speed DC switching circuit for
on/off or PWM control (up to 1 KHz) utilizing optically isolated low dissipation FET outputs rated
at either 120 or 160 Amps at 48, 72 or 150 VDC Operating Voltage.
FEATURES
120 or 160 Amp DC Load Ratings @ 40ºC ambient w/heat sink
Single Pole Single Throw Normally Open operation (SPST/N.O.)
LED Input Status indicator standard
IEC 60947-4-1 Rated, UL & cUL
MOUNTING INSTRUCTIONS
Please read all installation instructions before using your HDC Series Solid State Contactor (SSC).
Choose one of the two mounting options and follow the instructions.
Mounting on Heat Sink
Select adequate heat sink (see thermal derating curves).
Be sure to use thermal pad or thermal compound
between the SSC and the selected heat sink.
HDC Series Contactor mounting slots have a diameter of
0.2 in (5.0 mm). Four screws are needed (not included) to
mount the SSC onto heat sink (See fig. 1). Choose screw
length considering the mounting surface and that HDC
Series baseplate thickness is 0.125 in (3.2 mm).
Before applying full torque, tighten down all 4 screws
until they contact the baseplate. Then, tighten them to 20
in-lbs (2.2 Nm) starting with one immediately followed by
the one in the diagonally opposite corner. After the first 2
screws are completely tightened, proceed tightening the
remaining 2 screws.
For optimal thermal performance heat sink fins should be oriented vertically to promote
natural airflow.
Mounting on Panel
Locate the panel section on which the HDC Series SSC will be mounted. Panel mount
surface must be clean, bare metal and provide adequate heat sinking capability.
Be sure to use thermal pad or thermal compound between the SSC and the panel.
HDC Series Contactor mounting slots have a diameter of 0.2 in (5.0 mm). Four screws are
needed (not included) to mount the SSC onto panel. Choose screw length considering the
mounting surface and that HDC Series baseplate thickness is 0.125 in (3.2 mm).
Before applying full torque, tighten down all 4 screws until they contact the baseplate.
Then, tighten them to 20 in-lbs (2.2 Nm) starting with one immediately followed by the one
in the diagonally opposite corner. After the first 2 screws are completely tightened,
proceed tightening the remaining 2 screws.
TABLE 1. Accessories
Hardware Kit
Heat Sink
Thermal Resistance
Part No.
HK1
HS103 / HS103DR
HS053
(A)
See compatible accessories in TABLE 1.
(B)
For maximum ratings use heat sink ratings shown in HDC series derating curves (see
product datasheet).
(C)
Load can be wired to either terminal 1 or terminal 2. Proper polarity must be observed all
the time for the power supply and load.
(D)
DC inductive loads must be diode supressed. Diode not included.
(A)
(B)
fig. 1
HDC Series SSC
mounted on HS053 heat sink
(B)
Lug Terminal
Thermal Pad
[ºC/W]
1.0
TRM3/0
HSP-3
HSP-5
0.5
PART NUMBER NOMENCLATURE
Series
HDC
100
Operating Voltage
60: 7-48 VDC
100: 7-72 VDC
200: 7-150 VDC
Required for valid part number
For options only and not required for valid part number
WIRING DIAGRAM
(C, D)
AC Input
-
V
Load
LOAD SIDE
160A 150VDC GENERAL USE UL508
- / L2
S O L I D S T A T E C O N T A C T O R
HDC200A160
INPUT
90-140 VAC
STATUS
( )
(A)
Terminals
For maximum ratings, for 120 Amp models use Crydom lug terminal TRM3/0 or
other lug terminal with a diameter of 0.375 in (9.52 mm), 1 AWG (42.4 mm
insulation wire installing capable.
For maximum ratings, for 160 Amp models use Crydom lug terminal TRM3/0 or
other lug terminal with a diameter of 0.375 in (9.52 mm), 2/0 AWG (67.4 mm
insulation wire installing capable.
Wire Size
Maximum wire size capacity per terminal: Input 12 AWG (3.31 mm
Quick Connect Terminals, Output 2/0 AWG (67.4 mm
according to actual load current. See TABLE 2.
Connections
First install Lug Terminal (Item 1 on fig.2) followed by Washer Int. Tooth-Lock
(Item 2 on fig.2) and finally Nut Hex (Item 3 on fig.2)
Transient Protection
An inductive load will produce harmful transient voltage when it is turned off. The more perfect the switch,
the larger the transient voltage. The MOSFET output is so nearly ideal switch that the transient voltages
produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should be fast
recovery type with PIV rated greater than twice the supply voltage.
Important Considerations
WARNING! Do not try to unscrew Terminal Studs from Product.
Be sure to use input and output voltages within operating ranges.
LED indicates only input status. It does not represent output status.
HDC Series
Output Terminal
Part No.
HDCxxxx120x
Nut Hex/Washer Int. Tooth-Lock
Combo Type 3/8"
HDCxxxx160x
Control Voltage
Thermal Pad
A: 90-140 VAC
Blank: Not Included
D: 4.5-32 VDC
H: Included
A
120
H
Rated Load Current
120: 120 Amps
160: 160 Amps
DC Input
Load
160A 150VDC GENERAL USE UL508
+ / L1
- / L2
S O L I D S T A T E C O N T A C T O R
( )
( – )
2
) 75ºC
) 75ºC
2
) through
2
). Choose wire gauge
2
TABLE 2
Maximum Torque
Torque
lb in (N m)
lb in (N m)
300 (33.9)
225 (25.4)
-
V
LOAD SIDE
+ / L1
HDC200D160
INPUT
4.5-32 VDC
-
+
STATUS
( + )
3
2
1
fig. 2
Lug Terminal
Connections
Wire Size for Max. Ratings
AWG (mm
2
)
1 (42.4)
2/0 (67.4)
Rev. 062413

Advertisement

loading
Need help?

Need help?

Do you have a question about the Crydom HDC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for CST Crydom HDC Series

  • Page 1 HDC Series PART NUMBER NOMENCLATURE DC Load Solid State Contactors Control Voltage Thermal Pad A: 90-140 VAC Blank: Not Included Series D: 4.5-32 VDC H: Included The HDC Series Solid State Contactors (SSCs) are designed for control of high power DC loads such as brakes, clutches, coils, electro magnets, heaters, lamps, motors, solenoids, etc., where long life and fast switching are required and traditional mechanical contactors or relays don’t provide the required life, performance or service levels.
  • Page 2 DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF RIESGO DE RISQUE DE GEFAHR EINES RISCHIO DI 存在电击、 ELECTRIC DESCARGA DESCHARGE ELEKTRISCHE SCOSSA 爆炸或电弧 SHOCK, ELECTRICA O ELECTRIQUE N SCHLAGES ELETTRICA O 闪烁危险 EXPLOSION, EXPLOSION. OU EXPLOSION ODER EINER DELL’ESPLOSI OR ARC FLASH.

This manual is also suitable for:

Crydom hdc 60a 120Crydom hdc 60a 120 hCrydom hdc 60a 160Crydom hdc 60a 160 hCrydom hdc 60d 120Crydom hdc 60d 120 h ... Show all