  • Page 1 Powador Grounding Kit XP Series Installation Instructions...
  • Page 2 Powador Grounding Kit XP Series Installation Page 3 XP Series Powador Grounding Kit_EN...
  • Page 3 X P Series Po wador Groun din g Ki t Installing the XP Series Powador Grounding Kit 1. Remove all connected cables from the ground fault monitor. 2. Take out the circuit board and the ground fault monitor. Page 4 XP Series Powador Grounding Kit_EN...
  • Page 4 X P Series Po wador Groundi ng Ki t 3. Remove the cables connected to connector CN5 on the DSI circuit board (wire P4P-PCB2, P4N-PCB2). 4. Remove the cable from the cable duct (wires P4P-PCB2 and P4N-PCB2). Page 5 XP Series Powador Grounding Kit_EN...
  • Page 5 X P Series Po wador Groun din g Ki t Remove the PE cable. For negative grounding (-) of the PV generator, remove wire MP1002. * For positive grounding (+) of the PV generator, remove wire MN1002. Page 6 XP Series Powador Grounding Kit_EN...
  • Page 6 X P Series Po wador Groundi ng Ki t For negative grounding of the PV generator, remove wire MP1002 from the fuse at the DC+ input. For positive grounding of the PV generator, remove wire MN1002 from the fuse at the DC- input.
  • Page 7 X P Series Po wad or Grou ndi ng Kit Mount the XP series Powador grounding kit in the inverter. Wire No. PE PE Cable 10. Ensure the correct installation direction of the grounding fuse. The stud has to face towards the switch. In the case of reverse installation the inverter will not be notified if the fuse blows.
  • Page 8 X P Series Po wador Groundi ng Ki t 11. Connect wire K4B1-TD10 to point 1 of the fuse holder, and wire K4C1-TD10 to point 2 (see the following figure). Wire No. K4C1-TD10 Wire K4B1-TD10 Wire K4C1-TD10 12. Open the fuse holder and connect wire MN1002 to the fuse holder in order for negative grounding (-) of the PV generator.
  • Page 9 X P Series Po wad or Grou ndi ng Kit 13. Connect the PE cable on the grounding screw. 14. Close all covers. Page 10 XP Series Powador Grounding Kit_EN...
  • Page 10 Carl-Zeiss-Straße 1 · 74172 Neckarsulm · Germany · Tel +49 7132 3818-0 · Fax +49 7132 3818-703 · info@kaco-newenergy.de · www.kaco-newenergy.de...