Milton Roy LINC L471 Series Instruction Manual

Milton Roy LINC L471 Series Instruction Manual

Electric level controls

Advertisement

I N S T R U C T I O N M A N U A L
E L E C T R I C
L E V E L
C O N T R O L S
LINC L471 • L471SC • LV471 • L971
SERIES
Recognized as a
world-class leader in
Electric & Pneumatic
level control switches,
flow indicators,
chemical metering
pumps, and
allied products.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LINC L471 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Milton Roy LINC L471 Series

  • Page 1 I N S T R U C T I O N M A N U A L E L E C T R I C L E V E L C O N T R O L S LINC L471 • L471SC • LV471 • L971 SERIES Recognized as a world-class leader in...
  • Page 2 I N S T R U C T I O N M A N U A L O R D E R I N G I N F O R M A T I O N To Order, Call 800.455.LINC Or FAX your order anytime to 215.293.0498 For the Nearest Authorized...
  • Page 3: Table Of Contents

    I N S T R U C T I O N M A N U A L Contents –L471, 471SC, LV471, L971 Electric Level Controls ......Page L471 &...
  • Page 4: L471 & L471Sc Series Ordering Chart

    LEVEL CONTROL SWITCHES L I N C - L 4 7 1 & L 4 7 1 S C S E R I E S The LINC-L471 & L471SC Series: Electric Level Control Switches Application: Benefits: Features: • Easy to Repair........ •...
  • Page 5 LEVEL CONTROL SWITCHES L I N C - L 4 7 1 & L 4 7 1 S C S E R I E S Specifications: L471 & L471SC Series Electric Level Control Switches Pressure: 1,500 psi standard, available to 5,000 psi, (1,500 psi maximum with the Manual Override option) Temperature: 40°F to + 400°F standard.
  • Page 6: Scope Of This Manual

    I N S T R U C T I O N M A N U A L P R O D Scope Of This Manual: This manual describes and pro­ vides instructions and parts lists for the LINC-L471, LINC­ L471SC, LINC-LV471 and LINC-L971 Series Electric Level Controls.
  • Page 7: Installation

    I N S T R U C T I O N M A N U A L Installation: Before installing the level con­ trol, inspect the unit for any damage. The float arm must pivot freely. Thread the level control into the desired connec­ tion.
  • Page 8: Maintenance

    I N S T R U C T I O N M A N U A L Maintenance: connected across the common The LINC-L471 and LINC­ and normally closed contacts. L471SC Series electric level Interrupt the coil power supply controls have been designed to several times while observing be as maintenance free as pos­...
  • Page 9: L471-01, 21 Level Switch Parts List

    I N S T R U C T I O N M A N U A L Figure 1, LINC L471-01 Level Switch MANUAL OVERRIDE OPTION MUST BE INSTALLED WITH CONDUIT CONNECTION IN 12:00 O’CLOCK POSITION. The LINC 471-01 & 471-21 Series Parts List. Model L471-01 L471-21...
  • Page 10: L471-02, 03 Level Switch Parts List

    I N S T R U C T I O N M A N U A L L I N C - L 4 7 1 - 0 2 & L I N C - L 4 7 1 - 0 3 Figure 2, LINC L471-02 &...
  • Page 11: L471-01-04 Level Switch Parts List

    I N S T R U C T I O N M A N U A L Figure 3, LINC L471-01-04-N Level Switch (SUPPLIED WITH 1/2˝ REDUCER BUSHING) Model LINC L471-01-04-N The LINC 471-01-04-N Series Parts List. Model L471-01-04-N Item Part # Description Material...
  • Page 12: L471-39, 79 Level Switch Parts List

    I N S T R U C T I O N M A N U A L & Figure 4, LINC L471-39 & 79 Level Switch The LINC 471-39 & 79 Series Parts List. Model L471-39 L471-79 Item Part # Part # Description Material...
  • Page 13: L471-69, 89 Level Switch Parts List

    I N S T R U C T I O N M A N U A L & Figure 5, LINC L471-69 & 89 Level Switch MANUAL OVERRIDE OPTION MUST BE INSTALLED WITH CONDUIT CONNECTION IN 12:00 O’CLOCK POSITION. The LINC 471-69 & 89 Series Parts List. Model L471-69 L471-89...
  • Page 14: Electric Relays: Installation And Maintenance

    I N S T R U C T I O N M A N U A L Electric Relays Installation & Maintenance: • AC Voltage DPDT Plug-In Type Relay Or DC Voltage DPDT Plug-In Type Relay: 1. Check the relay coil to assure it is rated for your source voltage.
  • Page 15: Electric Relay 21593 Parts List

    I N S T R U C T I O N M A N U A L Figure 6, Electric Relay: LINC 21593 1" NPT (P) CONDUIT CONN. (SUPPLIED WITH ½" REDUCER BUSHING) L21593 Model LINC-21593 115 VAC Plug-In Relay Item Part # Description...
  • Page 16: L471Sc-01, 02 Level Switch Parts List

    I N S T R U C T I O N M A N U A L L I N C - L 4 7 1 S C - 0 1 & L I N C - L 4 7 1 S C - 0 2 Figure 7, LINC L471SC-01 &...
  • Page 17: L471Sc-03, 04 Level Switch Parts List

    I N S T R U C T I O N M A N U A L L I N C - L 4 7 1 S C - 0 3 & L I N C - L 4 7 1 S C - 0 4 Figure 8, LINC L471SC-03 &...
  • Page 18: Lv471 & L971 Series Ordering Chart

    LEVEL CONTROL SWITCHES L I N C - L V 4 7 1 & L 9 7 1 S E R I E S Specifications: LV471 Vertical Series & L971 Extended Body Series Electric Level Control Switches Series: LV471 Vertical L971 Horizontal Extended Body Series Pressure: 250 psi...
  • Page 19 I N S T R U C T I O N M A N U A L 1 : V Figure 9, LINC LV471-04, Vertical Level Switch Product Description: The LV-471 is used as a high or low level control to sound alarms, operate control equip­...
  • Page 20: Lv471-04, Lv471-04-04 Level Switch Parts List

    I N S T R U C T I O N M A N U A L The LINC LV471-04 Normally Closed Parts List. Model LV471-04 Normally Closed Item Part # Description Material 1 ..20119..... . Conduit Adapter ....316 ss ..1 2 .
  • Page 21 I N S T R U C T I O N M A N U A L L I N C - L 9 7 1 S E R I E S : E X T E N D E D B O D Y LINC L971 Series: Extended Body Product Description:...
  • Page 22: L971-01, L971-01-04 Level Switch Parts List

    I N S T R U C T I O N M A N U A L L I N C - L 9 7 1 S E R I E S : E X T E N D E D B O D Y Figure 10, LINC L971-01 and L971-01-04-N Series: Extended Body (SUPPLIED WITH 1/2"...
  • Page 23 —NOTES—...
  • Page 24 © Copyright 2004, 2011 Milton Roy Lit # 49752 10-2011...

Table of Contents

Save PDF