Art. Nr. 0618018109000 V14 A16
Complete product information
180.18-AL"
718
15
781
Installation of the combustion chamber liner:
Note: Labels with the short designations are attached to the mounting parts.
1. Install first row: first HSM (rear block centre) (top groove rearward), then rear blocks left and right (top groove
rearward) and front blocks.
2. Insert bottom blocks 1, 2 and 3.
3. Insert ash pan (5) and grate (9).
4. Install second row: rear blocks and lateral blocks.
5. Insert insulating block (16) and draught deflector plate (10).
Installation of the insulating block: Insert insulating block (16) with the short edge into the upper sheet steel groove
(see drawing) and let slip into the lower sheet steel groove.
Installation of the draught deflector plate: Insert draught deflector plate (10) slantwise (bevelled corners at the back)
and place it on the lateral sheet steel angles, then lift the front edge and place it on the support plate.
Important: Push the draught deflector plate to the front until the limit stop is reached!
Important: After cleaning of the appliance, or before returning it to service, checks must be carried out to ensure that
the baffle plates are in the correct position (see diagram).
Suitable fuels:
The following fuels are permitted for use in your wood burning stove (see also section 5.1):
Dry, well seasoned, unadulterated wood and wood briquettes which comply with DIN 51731
, „HAAS+SOHN KOMFORT IV
1
16
10
2
3
14
20
17
12
11
13
9
5
18
7
Ø100
150
270
19
No.
Product no.
1
2
0618018105300
6
3
5
0618018005600
8
6
0618018015002
7
0089000020005
8
9
0020100130005
10
0050500040005
11
12
0618516075310
13
0420114005371
14
0618018025301
15
0088400060005
16
0050500050005
17
0618018105035
18
0088500050005
19
20
0618618005036
Description
Body of the stove
Door to the combustion
chamber
Refractory
Ashpan
Supports for the
exhaust flue
Adjustable feet
Secondary air
Grate 260x152
Plate for diverting the
exhaust Glases
angled upwards
Air intake control
Fitting for the door
handle
Door handle
Inspection window
Door spring
Insulating brick
Door latch
Socket for the pipe
supplying air from
outside Ø 100
Air duct
Bottom plate