General; Specifications - Motorola R-2200 Operator's Manual

Communications service monitor
Hide thumbs Also See for R-2200:
Table of Contents

Advertisement

SECTION!
SPECIFICATIONS
1.1.0 GENERAL This section lists the physical, electrical
and input/output characteristics of the Communications
Service Monitor shown in figure 1-1.
1.2.0 SPECIFICATIONS
Modes:
AM/FM Generate, Monitor Power Monitor,
Voltmeter DC, RMS, AC, RF Wattmeter and
Load, Oscilloscope
Signal Generator Mode
FREQUENCY
Range:
200kHz to 999.9999 MHz
Resolution:
100Hz
Accuracy:
Same as time base
OUTPUT (16 dB variable
in 10 dB steps over 8
ranges)
Range:
.05uV to 800uV (low level output)
Accuracy:
40uV to 1V (high level output)
±2 dB over the .1 uV to 1V range of output level
± 2 dB leveling over the 200 kHz to 750 MHz
freq. range ± 3 dB leveling over the 750 MHz to
999.9999 MHz frequency range ± 1 dB over the
operating temperature range ref. 25° C
PURITY
Spurious:
-40 dB
Harmonics:
-15 dB (step attenuator
=
0 dB, 0 dBm out)
FREQUENCY
MODULATION
Deviation:
0 to 50 kHz peak
FM Noise:
100Hz
External/Internal
Frequency Range:
5Hz to 10kHz
Modes:
External, internal or microphone (any or all)
AMPLITUDE MODULATION
Range:
0 to 50% from 1 to 500 MHz
External/Internal
Fre~uency
Range:,
xternal Input:
100Hz-10kHz(± 1 dB)
Approx. 150mV for 50% BNC connector
Modes:
Internal, external, microphone or all
simultaneously
Monitor Mode
Frequency Range:
3 MHz to 999.9999 MHz useable to 100 KHz
Resolution:
with reduced sensitivity.
100Hz
Accuracy:
Same as time base
Frequen~
Error
In icator:
Digital Display of frequency error and bar graph
Sensitivity:
1.5 uV for 10 dB EIA SINAD (narrowband ± 7
(Over the 3 MHz to
KHz mod. acceptance)
5 uV for 10 dB EIA
999.9999 MHz range)
SINAD (wideband ± 100 kHz mod. acceptance)
5 uV for 10 dB EIA SINAD AM
Spurious Response:
-40 dB Typical
0 dB image ± 21 .4 MHz
-10 dB at L.O. harmonic ± 10.7 MHz
FM DEVIATION
MEASUREMENT
Range:
1, 10, 100kHz full scale
Accuracy:
± 5% of reading ± 100 Hz, 500 Hz to 50 kHz
deviation, ± 10% of reading 50 kHz to 75 kHz
AM MODULATION MEASUREMENT
Range:
0 to 100%
Ace
!;I
racy:
±5% of full scale
RF WATTMETER
AND LOAD
Frequency Fhnge:
1 MHz to 1000 MHz
Power Range:
.5 watt to 125 watt
Accuracy:
±10%
Protection:
over temp. and over power alarms
1-2
General
OSCILLOSCOPE
Size:
2.5 in diagonal
Freq. Response:
DC to .5 MHz (3 dB point)
EXTERNAL VERTICAL
INPUT
10 mV, 100 mV, 1 V, 10 V per division
Ranges:
1us, 10us, 100us, 1ms, 10ms, 100ms per
Sweep Rates:
division
Sync:
Automatic or adjustable level triggering
DIGITAL VOLTMETER
Readout:
3 digit Autoranging 1, 10, 100, 300 volts full scale
DC Accuracy:
± 1% F.S. + LSD
AC
Accurac~:
±5% F.S.
AC Bandwidt :
50 Hz to 10kHz
CODE SYNTHESIZER &
AUDIO GEN.
Frequency Range:
50 Hz to 9.999 kHz
Resolution:
0.1 Hz 50 to 1000Hz, 1 Hz 1000Hz to 9999Hz
Accuracy:
±.01%
Special Function:
PL, DPL, DPL invert, 2 tone sequential, 2 tone
variable, tone remote
Output Level:
0 to 3 RMS
@
600 Ohms
SINAD Meter
Input level range:
.5 V to 10 VRMS
Accuracy:
± 1 dB
@
12 dB SINAD
Distortion:
(1 kHz using code
synthesizer for tone)
Range:
0 to 35 dB
Input Level Range:
.5 V to 10 VRMS
Accuracy
5% of F.S. from 1% to 50%
PL Counter
Range:
60 to 270Hz
Resolution:
0.1 Hz
TIME BASE
Standard TCXO:
Aging ± 1 x 10-6 Yr Temp. ± 1 x 10-6 from 0 to
+55
c
Optional OCXO:
Aging ± 1 x 10-6 Yr Temp. ± 5 x 10-6 max.
Power and Environmental
AC:
90 to 130, 180 to 250 V ac, 50/60Hz
DC:
+ 11.0 to + 17 V de
Optional Battery:
12 V battery provides approx. 1 hr. continuous
operation
Battery Weight:
8 lbs. (3.63 kg)
Temp. Range:
0 to +55 C
Dimensions:
7Vz"
high x 12'/z" wide x 14" deep
(19.0 em x 31.8 em x 35.6 em)
Weight:
30 lb. excluding battery pack (13.6 kg)
R-2400 Spectrum Analyzer
Dispersions:
1, .1, .01 MHz/div
Dynamic Range:
55 dB min.
Measurement Range:
-100 dbm to + 27 dbm at Antenna connector
using internal RF step attenuator
Accuracy: +/-5 db absolute (at frequencies
below 800 MHz); +/-2 db linearity.
Useable to +51 dbm at RF In/Out conn. (level
uncalibrated)
Display Range:
Level: 6 divisions at 10 db per division
Frequency: 8 divisions with switch selectable
dispersions of 1, .1, and .01 MHz per division
Dynamic Range:
Noise desensitization: -55 dbc at .01 MHz/div.
dispersion and 25 KHz freq. offset; -70 dbc at
1 MHz/div. dispersion and 1 MHz offset.
Audio Monitoring:
Simultaneous Monitor function with spectrum
analyzer display of received signal.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-2400

Table of Contents