Suction Overflow tank Introduction Thank you for choosing the AS Control Plus an innovative control system incorporating a microprocessor. lt will dramatically improve the energy efficiency of overflow / infinity swimming pools and avoid unnecessary energy losses. On our test Pool (50 m at 30 °C water...
Backwash menu Overflow tank menu; ECO menu Configuration menu Important informations Wiring diagram AS Control Plus with Badu Prime, Delta, Profi and Alpha Pump with Pentair IntelliFlow VSD and control IntelliComm II with Pump UWE EO PM with frequency converter AS...
Page 4
(5th probe) in the collection tank. Limits of liability: We do not assume any liability for the cost of loss of water, which is caused by the failure, and/or misuse of the AS Control Plus or the Besgo valves. AS Control Plus 02-2019 EN...
Page 5
The set temperature has not yet been reached. Filter key: Auto: filter operates according to the programmed filter time Off: filter is switched off filter operates permanently 02-2019 EN AS Control Plus...
If the OP is switched on, by pressing the OK key the motor current will be measured, displayed and saved for the connected pump. If you decide to connect a different pump to the AS Control Plus, you will need to determine the current for the new pump. You can exit the display of the current by pressing the MODE key.
1 and 200 seconds. If you choose the setpoint „compressor“ you can connect a compressor instead of a backwash valve. It will turn on before and during the backwash (Pause = Lead time). The compressor will be activated as well during overflow mode. 02-2019 EN AS Control Plus...
Page 8
CAUTION: (liability exclusion) Some pool manufacturers (polyester, liner) limit their warranty to use at temperatures of 30 to 35 °C. Potential damage to such pools or their covers is not covered by us. AS Control Plus 02-2019 EN...
Page 9
TIME OF DAY: By pressing the OK key you can select, by means of the arrow keys, the current time. Even after switching off the AS Control Plus the time is preserved by means of a back-up CR2032 battery.
In this example the heating will heat until 28 °C and then switch off. The heating will only switch on again when the water temperature drops below 27 °C. In this way you ensure that the temperature can only vary between 27 °C and 28 °C. AS Control Plus 02-2019 EN...
Page 11
Wiring diagram Art. No. 081190 Caution: Only 1 filter pump can be connected (230 VAC or 400 VAC). 02-2019 EN AS Control Plus...
Page 12
Speck Badu Prime Filter operation Art. No. 034110 via Overflow tank with Speck Badu Delta Art. No. 034113 Backwash with Speck Badu Profi Art. No. 034101 with Speck Badu Alpha Art. No. 034112 AS Control Plus 02-2019 EN...
Wiring diagram Wiring diagram Wiring diagram Art. No. 081190 Level Level with Pentair IntelliFlow VSD and control IntelliComm II Art. No. 034001 Level Art. No. 034006 Level 02-2019 EN AS Control Plus...
Page 14
Wiring diagram Art. No. 081190 with pump UWE EO PM Art. No. 037000 Control cable AS Control Plus 02-2019 EN...