Summary of Contents for Cleaver Scientific MICRODOC Series

  • Page 1 MICRODOC...
  • Page 3: Instruction Manual

    MICRODOC Instruction Manual Catalogue Numbers CSL-MICRODOC CSL-MICRODOC1D CSL-MDOCUV312 CSL-MDOCUV3121D CSL-MDOCUV254 CSL-MDOCUV2541D CSL-MDOCUV365 CSL-MDOCUV3651D CSL-MDOCUV254/312 CSL-MDOCUV254/3121D CSL-MDOCUV254/365 CSL-MDOCUV254/3651D CSL-MDOCUV312/365 CSL-MDOCUV312/3651D CSL-MDOCBASIC CSL-MDOCBASIC1D Record the following for your records: Model _____________________ Catalogue No. _____________________ Date of Delivery _____________________ Warranty Period _____________________ Serial No. _____________________ Invoice No.
  • Page 4: Table Of Contents

    Contents Instruction Manual Catalogue Numbers Contents Safety Information Installation Safety Environmental Conditions Avoiding electrical shock Avoiding Damage to the Instrument UV Tubes Disposal Symbols Packing List Specifications Operating Instructions Installation Connecting to UV transilluminator Camera set-up Operation Front Panel Turning on the system Agarose gel Imaging Troubleshooting Ordering information...
  • Page 5: Safety Information

    Safety Information Cleaver Scientific microDOC System has been tested and found to be compliant with CE regulations. microDOC system are also RoHS compliant. These limits were designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 6: Installation Safety

    10. The instrument is intended for scientific research use only and must be operated by qualified personnel who realize the potential risks of the use of this instrument. Cleaver Scientific makes no claim that its instruments are designed or certified as medical device; no...
  • Page 7: Environmental Conditions

    Follow the guidelines below to ensure safe operation of the unit. The microDOC System has been designed to utilize shielded wires thus minimizing any potential shock hazard to the user. Cleaver Scientific recommends against the use of unshielded wires. To avoid electrical shock: 11.
  • Page 8: Avoiding Damage To The Instrument

    Avoiding Damage to the Instrument Do not attempt to operate the device if it is damaged. Protect this unit from physical damage, corrosive agents and extreme temperatures (direct sunlight, etc.). For proper ventilation and safety, keep at least 10 cm of space behind the instrument, and at least 5 cm of space on each side.
  • Page 9: Packing List

    Packing List Each microDOC unit includes: • microDOC Hood with viewing screen (Or basic hood for microDOC BASIC) • Power Cable • High resolution camera & accessories • Memory card for image storage • USB memory card adapter • UV Imaging Filter •...
  • Page 10 The unit should be checked for damage when received. Cleaver Scientific is liable for all missing or damaged parts / accessories within 7 days after customer received this instrument package. Please contact Cleaver Scientific immediately regarding this issue. If no response within such period from consignee party, that will be consignee party’s whole...
  • Page 11: Specifications

    Specifications Camera Canon EOS 2000D Effective Pixels Approx. 24.1 megapixels Recording Media SD memory card, SDHC memory card, SDXC memory card Image sensor CMOS sensor Image Resolution 720 × 480 up to 6,000 × 4000 Focal Length & 18-55mm f/3.5-5.6 Maximum Aperture Lens Canon EF mount...
  • Page 12: Operating Instructions

    Operating Instructions Installation microDOC BASIC systems do not require installation and can simply be placed on an existing transilluminator. microDOC systems are delivered pre- assembled and do not require any complex assembly. Installation can be achieved in these simple steps. 1.
  • Page 13: Connecting To Uv Transilluminator

    Connecting to UV transilluminator microDOC systems can be connected to an existing transilluminator to allow control of UV or blue lighting and enable the safety switch to shut-off the UV lights when the microDOC door is opened. To connect the microDOC to a UV transilluminator, place the microDOC on the UV or blue transilluminator and follow these steps: 1.
  • Page 14: Camera Set-Up

    Camera set-up microDOC cameras are supplied pre-configured for use in gel documentation. The settings of the camera should not be changed upon installation. If at any point, the camera settings are altered, use to following instructions to return the camera to the optimum settings for gel documentation.
  • Page 15: Operation

    Operation Front Panel Toggle the internal white lighting, used for gel placement and visible imaging. Toggle the UV transilluminator light on and off Turning on the system Turn on the system by plugging in the power cable, turning the mains power on, and moving the red rocker switch at the rear of the system to the on position.
  • Page 16 6. Close the microDOC door and switch off the white light. Select the appropriate filter on the filter slider. 7. Turn on the UV light source with the button on the front of the unit. 8. Use the camera lens to zoom in and out by rotating the main body of the lens.
  • Page 17: Troubleshooting

    Troubleshooting Many operating problems may be solved by carefully reading and following the instructions in this manual accordingly. Some suggestions for troubleshooting are given below. Should these suggestions not resolve the problem, please contact our SERVICE DEPARTMENT or a distributor in your region for assistance.
  • Page 18: Ordering Information

    Ordering information Gel Documentation System System only System With 1D Software microDOC CSL-MICRODOC CSL-MICRODOC1D microDOC System with UV Transilluminator (UVT312) CSL-MDOCUV312 CSL-MDOCUV3121D microDOC System with UV Transilluminator (UVT254) CSL-MDOCUV254 CSL-MDOCUV2541D microDOC System with UV Transilluminator (UVT365) CSL-MDOCUV365 CSL-MDOCUV3651D microDOC System with UV Transilluminator (UVT254/312) CSL-MDOCUV254/312 CSL-MDOCUV254/3121D microDOC System with UV Transilluminator (UVT254/365)
  • Page 19: Warranty

    Warranty The Cleaver Scientific Ltd. (CSL) units have a warranty against manufacturing and material faults of twelve months from date of customer receipt. If any defects occur during this warranty period, CSL will repair or replace the defective parts free of charge.