12.2.6 Recording Level Adjustment
Settings
AC mV meter
Input signal
Test tape
T a p e s e l e c t o r . . . . . . .
Mode
Connect to TP (DOL. L)
and TP (DOL. R)
333H2, - 10dBv (316mV)
to LINE INPUT terminals
STD-608A (STD-603,
sTD-604)
NORM (CrO2 , METAL)
Record
12.2.7 Limiter Effect Check
Settings
AC mV meter
. . Connect to OUTPUT ter-
minals
Input signal
. . . 333H2, OdBv (1V)
to
LINE
INPUT
terminals
Test tape
STD-608A
T a p e s e l e c t o r . . . . . . .
N O R M
Mode
. .. Record
Fig. 12-15 Limiter effect check
Fig. 12-14 Recording level adjustment
Procedure
1. Adjust the INPUT level control so that the
meter reads - 5.2dBv (549mV).
2. Switch the DOLBY NR switch ON.
3. Record the 333H2, - 10dBv signal on the
STD-608A test tape. Then adjust VR102
(L ch) and VR202 (R ch) so that the meter
reads - 5.2dBv (549mV) when the recorded
signal is played back.
4. Switch the tape selector to the CrO2 position
and repeat step 3 using the STD-603 test
tape. The playback output level should lie
within - 5.2dBvt1.5dB.
5. Then switch to the METAL position and repeat
using the STD-604 test tape. The playback out-
put level should again lie within the - 5.2dBv
t1.5dBv range.
Procedure
1. Set the INPUT level
position.
2. Confirm the AC mV
dB.
control to the click stop
meter reads -2dBvt1.5
5 . ? d a v { s h v
)