The heat pump has two modes: Smart and Silence. They have different advantages under different conditions MODE RECOMMENDATION ADVANTAGES Heating capacity: 20% to 100% capacity Smart mode Intelligent optimisation As standard Fast heating Silence mode Heating capacity: 20% to 80% capacity Use at night Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
1.4.2. When moving the heat pump, do not lift the water union. This will damage the titanium heat exchanger. 1.4.3. Do not obstruct the air inlet or outlet of the heat pump. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Page 6
1.4.6. If you detect any abnormal noises, odours, smoke or leaks from the heat pump, immediately switch off the power supply and contact your local dealer. Do not attempt to repair the heat pump yourself. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Page 7
1.4.7. Please note that following codes are not failures. CODES No water flow Anti-freezing reminder Out of the operating range Insufficient water flow or pump blocked Power abnormal Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Turn on the heat pump and the fan will start to run after 3 minutes. In another 30 seconds, the compressor will start to run. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Page 9
5 seconds to start compulsory defrost. (Note: the break between compulsory defrost needs to be more than 30 minutes.) T he defrost symbol will flash when the machine is in compulsory defrost mode or auto defrost mode. Compulsory defrost will take the same amount of time as auto defrost. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
When the water in machine freezes in When the water in machine freezes in winter season, the titanium heat winter s eason, t he t itanium heat exchanger may be damaged. exchanger may be damaged. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
2100 x 1090 x 1280 The sizing of heat pumps are based on pool volume for seasonal swimming with the use of a Heatseeker Diamond Pool Cover. The values indicated are valid under ideal conditions: Pool covered with an isothermal cover.
When storing or moving the heat pump, please ensure the unit remains in an upright position at all times. 4.2. When moving the heat pump, do not lift the water union. This will damage the titanium heat exchanger. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
ATTENTION 5.1. NOTICE BEFORE INSTALLATION 5.1.1. Plumbing connections must be made with solid PVC pipe. Usage of flexible PVC pipe is not recommended. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
5.2. INSTALLATION INSTRUCTIONS 5.2.1. Location and size The heat pump should be installed in a place with good ventilation. ATTENTION Do not obstruct the air inlet or outlet of the heat pump. The efficiency may be reduced or even stopped. *Minimum distance 1. Filter 2. Water processor 3. Water switch Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Page 15
MODEL (UNIT = MM) VortexC 150T/60kW 1000 1110 1070 1000 1260 MODEL (UNIT = MM) VortexC 300T/120kW 1000 1630 1090 1050 2100 1280 Above data is subject to modification without notice. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Page 16
The above data is adapted to power cord ≤ 10m. If power cord is ≥ 10m, wire diameter must be increased. The signal cable can be extended to 50m at most Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Page 17
Step 6. Restore the internal panel. Step 7. Fix the internal panel by using the two Step 8. Restore the panel. screws removed previously. Step 9. Fix the panel using the three screws removed previously. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Page 18
Power Supply Fuse 400V 50Hz Breaker Earthing • Must be hard wired, no plug allowed • For your safe use in winter, it’s strongly recommended to equip heating priority function. ATTENTION Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
3 minutes, in another 30 seconds, the compressor will start to run. After pool heat pump starts up, check for any abnormal noise from the heat pump. Check the temperature setting Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
If above solutions don’t work, please contact your installer with detailed information and your model number. Don’t try to repair it yourself. Please don’t try to repair the heat pump by yourself to avoid any risk. ATTENTION Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
By following the instructions in the heat pump instruction manual, setting a start and stop time will ensure that the heat pump is not sampling the water temperature and running throughout the night if running noise is a factor. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
5 minutes. If after 5 minutes, the temperature of the water is above the required temperature, the filtration turns off for one more hour. Otherwise, the filtration and the heat pump are going to keep on operating until the desired temperature is reached. VORTEX LINK CHLORINATOR PLUG INTO 240 GPO HEAT PUMP SWITCHING LEAD PUMP FILTER CHLORINATOR CELL FILTRATION PUMP Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
The chlorinator connects directly into a general power outlet, not into an extension lead. Plug the black 2 pin power lead from the VortexLink into the chlorinator. Set the chlorinator to operate for the required filtration and dosing requirements. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
(d) in the case of other heat pump components, a two (2) year limited warranty from Supreme Solar Pty Ltd, 2/19 Enterprise Drive, Bundoora, Victoria, 3083 (Phone: (03) 9460 4200, Email: info@supremeheating.com.au); Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Page 27
(g) by other abuse or misuse caused by the Purchaser or a third party. Subject to clause 9, any condition or warranty which would otherwise be implied in this agreement or in relation to the Product is hereby excluded. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...
Page 28
Supreme Solar Pty Ltd pool heating system (c) Governing law (paragraph 16): Victoria, Australia Consumer guarantee 18 This warranty is provided in addition to consumer guarantees and does not alter, limit or replace them. Heatseeker VortexC Inverter Heat Pump Installation & User Manual...