Page 1
V115 PUMP OUT MANUAL AC12H REVISED: 03.14.2019...
Page 2
Aramsco 4282 S 590 W Salt Lake City, UT 84123 801-268-2673 801-268-3856 FAX Information in this manual is subject to change without notice and does not represent a commitment on the part of Hydro-Force or its parent or affiliated companies.
Technical Specifications V115 Pump-out Height: 18-1/2” Length: 15” Width: 14-3/8” Weight: 28.4lbs. Tank Capacity: 11 gallons Pump-out Pump: Little Giant 115VAC 8-20 gpm Maximum psi 11.4 – Maximum pumping height 26 ft. Power Draw: 5.00amps Waste Pump Standard Equipment V115 Pump-out Tank Unit Pump-out Hose: 50’...
Page 4
Additional / Optional Equipment Extra Pump-Out Hose 3/4” x 50’: AH65 Replacement SS Filter: AC11S GFCI Protected Extension cord 12/3 x 50’: NM4407 Extension Cord 12/3 x 50’: AX33 Shockbuster - External GFCI Protector: AX126 2” Flash Cuff Male Starter Cuff AH203 AH65 AC11S...
Page 5
Section Safety CAUTION! This machine is an electrical appliance. Care must be taken to reduce the risk of electrical shock. • READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING THE V115 Pump- out. • To reduce the risk of property damage or injury, repairs to electrical systems should only be performed by experienced technicians.
Page 6
WARNING! This machine must be protected from conditions which may damage the pump, tank, hoses and other components. • Freezing of water in this machine will cause serious damage. The V115 Pump-out and hoses must be protected from freezing temperature. Store, transport, and use this equipment only in temperatures well above freezing.
Section Operation Procedures Knowledge of the proper operation of the V115 Pump-out is required to ensure user safety and efficient performance of the extractor. SET UP AND OPERATION Vacuum Hose Connection: Connect the hose cuff from the 2” vacuum hose coming from the cleaning tool to one of the 2” hose barbs on the inlet side of the V115 Pump-out.
Electrical Connection: Plug an extension cord into an 115v AC wall outlet. Use a GFCI protected outlet, a GFCI protected cord or an external GFCI device to reduce the risk of electrical shock. The V115 Pump-out only draws 5amps of power so most household outlets will safely handle the load. If a circuit breaker trips during operation, reset the breaker and move the cord to another outlet as needed.
Page 9
Shutdown Procedures: Turn the V115 Pump-out power switch to the OFF position and disconnect the power cord. Disconnect the pump-out hose from the discharge port fitting and replace the cap. Roll up the pump-out hose toward drain to remove remaining water from hose. Connect ends of hose together to prevent dirty water from dripping from hose during transport.
Section Troubleshooting Troubleshooting – V115 Pump-out Problem Cause Solution Reset breakers or move cords to other outlets. Repeated Pump-out not tripping of breaker may indicate a short circuit. Check cord working Building circuit breaker tripped. and unit wiring and repair before using pump-out.* Reset GFCI, replace GFCI or move to other outlet Repeated tripping of GFCI may indicate a short circuit.
Section Maintenance Proper maintenance is required to keep the V115 Pump-out operating properly, prevent downtime and to extend the life of your equipment. WARNING: Disconnect electrical power before performing any service or maintenance inside switch box or before testing or repairing the pump, switches or power cord.
Page 13
Storage Prep and Freeze Protection Procedures: Your V115 Pump-out must be protected from freezing. Freezing can cause serious damage to the pump, and any other component containing water. If the V115 Pump-out is transported or stored in freezing temperatures, the following procedures should be performed. 1.
Page 14
Section Parts Replacement parts available for repair of your V115 Pump-out. 6 & 6A...
Page 15
PARTS SHOWN ON PAGE #14 PART #p DESCRIPTION PHY052-222 ELBOW 90° 2” FPT X 2” BARB (QTY 4) PHY052-219 ADAPTER 2” MPT X 2” SLIP PVC (QTY 4) PHY106-028 PLUG VAC STOPPER (QTY 2) NM4263 SCREW TEK #10 X 5/8” SS (QTY 2) NA041 HANDLE (QTY 1) NM4061...
Page 17
PARTS SHOWN ON PAGE #16 PART # DESCRIPTION PHY052-222 ELBOW 90° 2” FPT X 2” BARB PVC (QTY 4) PHY052-219 ADAPTER 2” MPT X 2” SLIP PVC (QTY 4) PHY106-028 PLUG VAC STOPPER (QTY 2) NM4263 SCREW TEK #10 X 5/8” SS (QTY 2) NA041 HANDLE (QTY 1) NM4061...
Page 18
PARTS SHOWN ON PAGE #18 PART # DESCRIPTION NM5051 STRAIN RELIEF 3/8” MPT (QTY 3) NM5239B NUT STRAIN RELIEF 3/8” FPT (QTY 3) PUMP OUT TANK – ALUMINUM (QTY 1) NM4464 1” X 4” ADHESIVE PADS (QTY 6) AC11S SS FILTER SCREEN (QTY 2) NM5053 PUMP OUT PUMP (QTY 1) NM5054...
Your V115 Pump-out is designed to give you years of reliable service. If a problem should arise use the troubleshooting section in the operation manual to diagnose and correct the problem if possible. If you are unable to determine the cause or solution to the problem contact your distributor or Hydro-Force for assistance.
Need help?