Powerturn Contents Introduction................................3 Symbols and illustrations ....................................3 Product liability .........................................3 Special cases ........................................3 More detailed information ....................................3 Terms .............................................4 Fundamental safety precautions ........................6 Description .................................7 Types of installation and versions ................................7 Set-up ............................................7 Overview of the modes of operation ................................8 Operating elements......................................8 3.4.1 Operating modes push button with operating modes display ......................8...
Powerturn Introduction Introduction 1. 1 Symbols and illustrations Warning notices Warning notices are used in these instructions to warn you of personal injury and property damage. Always read and observe these warning notices. Observe all the measures that are marked with the warning symbol and warning word. Warning Warning word Meaning symbol...
Low-energy function The GEZE Powerturn can be used as a low-energy drive. In low-energy function the force needed for opening and closing the door is reduced to 67 N and the opening and closing time is reduced. This lowers the danger of a per- son bumping into the moving leaf.
Page 5
Powerturn Introduction Term Explanation Electrical closing sequence control Closing sequence control In normal operation of double-leaf door drives, the closing sequence of the door leaves is controlled by the control units of the door drives, with the passive leaf being closed first.
à No changes may be made to the system without prior agreement from GEZE. à GEZE shall assume no liability for damage caused by unauthorised changes to the system. à The owner is responsible for safe operation of the system.
Powerturn Description Description 3. 1 Types of installation and versions à The door drive unit can be mounted in transom mounting at the lintel or in door leaf installation on the door leaf. à The door drive is available as 1-leaf or 2-leaf version. à...
Description Powerturn Overview of the modes of operation The following modes of operation can be set on the Powerturn: à Automatic mode à Exit only à Hold open à Night mode à OFF Mode of operation MPS/MPS-ST* DPS** Explanatory notes Display Automatic Door opens and closes again.
Powerturn Description 3.4.2 Mechanical programme switch MPS (optional) à Can be connected in addition to the operating modes push button (21). At the mechanical programme switch MPS, the mode of operation for the system is selected and the corresponding programme is displayed. The mechanical programme switch is accessible for everyone without a key switch.
Description Powerturn Door in normal operation In normal operation, the door is automatically opened and closed. When Powerturn IS/TS is used, only the active leaf opens automatically. The passive leaf has to be opened manually. What happens? What does the door do? An activation device (push button, switch or movement Door opens, waits the hold-open time and then closes.
Powerturn Operation Which switch/button? What does the switch/button do? Double push button In the case of 2-leaf drives, a button with a double function can be connected via a configurable push button. This means that 1-leaf or 2-leaf opening is possible by pressing the push button.
Operation Powerturn 4. 1 .2 Selecting the mode of operation at the mechanical programme switch MPS With the programme switch MPS Turn the rotary switch (22) to the required mode of operation. The mode of operation is set. Mechanical programme switch MPS With the programme switch MPS-ST (key switch Operation of the mechanical programme switch MPS-ST is only possible with the supplied key (23).
Powerturn Troubleshooting Troubleshooting Problem Cause Remedy Door only opens and closes Obstruction in travel path Remove obstruction and check door leaf slowly for ease of movement Have the door close completely once; after detection of an obstruction the door moves at a safe speed until the complete closing procedure has been completed.
Maintenance must be carried out at least once a year or according to the maintenance display on the display programme switch. Installation, maintenance and repair work must be performed by properly trained personnel authorised by GEZE. If a dot appears in the bottom right-hand part of the display, maintenance is due.
Powerturn Technical data Technical data Opening time: 3 … 25 s Closing time: 5 … 25 s Mains voltage 230 V AC –15 %, +10 % Frequency 50 Hz Protection rating Capacity rating 200 W Mains connection Fixed connection (installation cable or drip loop) Primary fuse –...
Need help?
Do you have a question about the Powerturn (1-leaf) and is the answer not in the manual?
Questions and answers