Download Print this page

Nass Magnet 0558 Operating Instructions Manual

Ex na, t solenoid coil

Advertisement

Quick Links

Ex nA, t Solenoid Coil Type 0558
Assessment no. nm 13 ATEX 0069 X
Operating Instructions
Dear Customer!
To ensure the function and for your own safety, please read these operating instructions carefully before you
begin with the installation. If there should still be any questions, please refer to nass magnet GmbH.
Tel
++49 (0) 511 6746-0
Fax
++49 (0) 511 6746-222
e-mail
vertrieb@nassmagnet.de
General terms and conditions
We are not liable for any damage caused by non-observation of this information as well as in case of
improper intervention regarding this device. Furthermore, warranty for the devices and accessories will
become void. Our general terms and conditions apply.
The nass magnet solenoid coil is designed for operation with the nass magnet armature assemblies and
nass magnet valve systems; please consider the corresponding power levels.
Applied standards in the Conformity Assessment:
EN 60079-0:2012+A11:2013
EN 60079-15:2010
EN 60079-31:2014
In its installed state the device is appropriate for potentially explosive gas atmospheres of Group IIC
(protection type "nA"). The Equipment Protection Level (EPL) is Gc for intended application in Zone 2,
ATEX Category 3G. Alternatively the device is appropriate for potentially explosive dust atmospheres
of Group IIIC (protection type "tc"). The according Equipment Protection Level is Dc for intended
application in Zone 22, ATEX Category 3D.
Beyond recognized rules of sound engineering practice these operating instructions refer to special
conditions for safe use as well as to further application conditions that must be observed in any case.
However, these operating instructions cannot consider all possible conditions and applications
completely, and do not replace the specifications valid in each case.
nass magnet GmbH
Eckenerstrasse 4-6
30179 Hannover
Germany
Doc. No. 108-720-0010
Revision 7
14 May 2019

Advertisement

loading

Summary of Contents for Nass Magnet 0558

  • Page 1 Dear Customer! To ensure the function and for your own safety, please read these operating instructions carefully before you begin with the installation. If there should still be any questions, please refer to nass magnet GmbH. ++49 (0) 511 6746-0...
  • Page 2: Installation

    When properly installed ingress protection IP65 is achieved. Observe the provided seals and the prescribed tightening torques pursuant to the assembly scheme. Only use original spare parts provided by nass magnet, otherwise to this assembly the ATEX attestation of conformity is not applicable any more.
  • Page 3: Assembly Scheme

    Assembly scheme...
  • Page 4: Technical Data

    Marking Typ 0558 xx/xxxx nm 13.0069 X II 3 G Ex nA IIC T5 Gc II 3 D Ex tc IIIC T95°C Dc Ingress Protection by Enclosure IP 65 Technical Data nass magnet Nominal Nominal Power Ambient Type No. Power Level...
  • Page 5: Operation

    Caution! Risk of injury! The solenoid valve can get very hot during continuous operation.  The Ex-solenoid coils Type 0558 of temperature Class T5 are designed for an ambient temperature range from -20°C to +50°C and media temperatures of -20°C to +50°C.
  • Page 6: Eu Declaration Of Conformity

    GmbH Eckenerstrasse 4-6 30179 Hannover, Germany Product, type-number / object of the declaration: Ex nA, tc Solenoid Type 0558 00 to 0558 99 The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: 2014/34/EU …relating to equipment and protective systems intended for use in potentially explosive atmospheres...