ebm-papst G3G146-CC11-14 Operating Instructions Manual page 10

Table of Contents

Advertisement

G3G146-CC11-14
Check the
Visual inspection At least every
insulation of
the wires for
damage
Check the ball
Manual check
bearings to
by turning the
ensure they
rotor in shut-off
are quiet, can
state
move easily
and are free of
play
Item no. 50245-5-9970 · Revision 75643 · Release 2011-11-24 · Page 10 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Replace wires
6 months
At least every
Replace
6 months
device in case
of noise,
difficulty of
movement or
clearance of
the bearings