Up and down moving 30mm Up and down moving 80mm bracket Fixation Red LED part Input voltage 110/220V±10% Input frequency 50/60Hz Input power 60VA Power Illumination: 4.5V Output voltage Fixation: Safe standard of IEC601-1, type Ⅰof BF Model electric Packing box 720mmx495mmx480mm Weight and Gross weight...
2. Installation 2.1 Cautions before the Installation 2.1.1 The earth cables on the moto-table and the power box must be connected well by the grounding wire (the wire is in yellow and green). 2.1.2 The earth wire must be connected well. 2.1.3 There are two boxes for slit lamp microscope (only one excluding moto-table).
2.3.2 Take out the moto-table and upend it on the ground. (Picture 2) Picture 2 2.3.3 Take out other parts. (Picture 3) Picture 3 2.3.4 Screw off the four inner 6-angle screws (picture 2); aim at the holes that are on the leg, match the position, and screw on.
Page 9
2.4.2 Take out the workbench, open the plastic toolbox (Picture 7), and find out four screws for the platform (Picture 8). 2.4.3 Put the workbench onto the moto-table; match the position of the apertures and the holes. (Notes: Do not press the plastic plug-wire) 2.4.4 Insert the screws and tighten them well.
DOWN Picture 12 Picture 13 2.5 Installation of microscope and pedestal (The second layer, picture Focus stick Microscope & pedestal Guide-way shroud Picture 14 2.5.1 Take out microscope and pedestal part according to picture 15 16 Notes: When taking them out, remember not to separate them. Picture 16 Picture 15 Picture 16...
Guide- Picture 17 Picture18 2.5.3 Screw off four screws on the guide-way (as picture 18 and cover the guide-way shroud on, and fasten the screws (as picture 19 Then, loose the locknut screws (picture 50 rotate the microscope arm left and right genteelly in order to install it well (After installing, there should be about 1mm interspaces, as picture 20 Locknut screw Locknut screw...
Page 12
Picture 23 Lighting Preset lens component 2.6.1 Take out the lighting component as picture 24 Picture 24 Picture25 2.6.2 Take the lighting arm onto the microscope by matching the position of the hole, loose the screw on the lighting arm (as picture 26 And move the lighting arm left and right softly, make them occlude well.
Page 13
Picture 28 Picture29 2.6.4 Find out the four holes at the bottom of the workbench (Picture 30 Fix hole Picture 30 Picture 31 2.6.5 Hold the jaw bracket, Aim it at the fixing holes, insert the four inner 6-angle screws one by one and fasten them (picture 31 Then, plug the power wire into socket on the lamp cover (picture 32 ) Picture 32...
Picture 35 Picture 34 2.7 Installation of Reflector 2.7.1 Take out the reflector in the toolbox, there are two reflectors totally, one is short, and the other is long. (Picture 36) Picture 36 Picture 37 2.7.2 Insert the long one into the reflector pedestal as picture 40. Picture38 Picture 39 2.8 Installation of the Breath Protector...
Picture 42 Picture 43 2.10 Checking after Installation (1) Eyepiece point to Zero (Picture 44)and tighten the central position fixation knob as the picture 45. Picture 44 Picture 45 (2) Turn the filter to the second grade (Heat absorption) as picture 48; turn the knob of length to 10mm.
Page 16
Picture 47 Picture 48 (4)Turn on power to turn on the light, and turn the adjusting knob of slit to 0 (picture 48)and observe the light spot, there should be a well-proportioned light on the stick, then, turn off the power. Then the whole installation is finished.
3. Operation 3.1 Turn on the power. 3.2 Turn on the light. 3.3 Before checking, insert the focus stick, and observe the slit image on the focus stick through eyepiece, and adjust the degree in order to make the slit images clear. (Different operator has a different degree).
4. Maintenance 4.1 Keep the room clean, airiness and dry, and use air-conditioner as possible. 4.2 If there is besmirch on the lens or reflector, use absorbent cotton with a little absolute alcohol to clean. 4.3 Replace the bulb: 4.3.1 Turn off the main power switch; 4.3.2 Take out the power wire plug.
Page 19
Fuse parts: The fuse of power box: 250V 2A The fuse of chief power: 250V 3A Every time before checking, please clean the chin rest. 4.4 Packing list Name Quantity Unit Moto-table (Optional) Unit Platform Unit Power box Unit Optics Chin rest Unit Power-wire...
5. Installation of Teaching Tube (Optional) Installing the teaching tube is the final step, after finished the whole configuration. 5.1 Screw off the lens sector, and take it off.
Page 24
6. Warranty States 6.1Our company provides information and data for the parts, which are made by Our Company. 6.2 Our company provides maintenance for whole life. 6.3 From the date of purchasing, with following the operation instruction, Our Company can provide free maintenance for one year.