Electronic drive and control systems for windows and doors (20 pages)
Summary of Contents for Roto E-Tec DoorDrive
Page 1
Window and Door Technology Roto E-Tec DoorDrive The concealed swing door drive for doors Installation, maintenance and operation instructions for timber and aluminium doors...
Page 2
Imprint Copyright: April 2013 Roto Frank AG Wilhelm-Frank-Platz 1 70771 Leinfelden-Echterdingen, Germany Telephone +49 711 7598 0 +49 711 7598 253 info@roto-frank.com www.roto-frank.com...
System overview ................17 Required fastening means ............. 18 Installation steps ................19 Wiring Connection diagram for Eneo C / CC with Roto E-Tec DoorDrive ..26 Permissible cable length ..............27 Commissioning Initial operation steps ..............28 Subject to change.
Page 4
Turn-Only sash doors ............ 46 Inspect and check possible hazardous locations and protection measures as per DIN EN 16005 ............. 47 Final comments ................49 Disposal ....................... 50 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
This manual also contains binding guidelines to ensure that the duty to instruct is observed through to the end-user. The information and instructions in this manual refer to the Roto E-Tec DoorDrive products. This manual should be stored in such a manner that it can be quickly used, if needed.
The “builder” target group includes all companies/persons who order doors for installation into their building project. End-users The “end-users” target group includes all persons who operate the installed doors. May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
(refer to page 45 – 49) in accordance with DIN EN 16005. Responsibility of builder The builder must forward the following documents to the end user: – Maintenance and operating instructions (with the focus on hardware) – Specifications/information for end-users (VHBE) Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
NOTE! This symbol and signal word indicate a potentially hazardous situation, which may lead to property or environmental damage if it is not avoided. May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
The warranty covers original Roto components only. Subject to technical modifications conducted as part of the improvement process for performance characteristics and further development.
– Is not suitable for use in escape routes and with fire protection doors Roto E-Tec DoorDrive is an aid which closes the door, but which does not lock it. The swing door drive is therefore not a theft- deterrent device and as such it does not absolve the user from his/her obligation to lock the door using the door lock.
Never insert metal objects into the Roto E-Tec DoorDrive openings, otherwise there is a risk of electric shock. – If the Roto E-Tec DoorDrive is in mounted into a metallic door sash, then the door leaf has to be properly grounded. NOTE! Professional installation and diligent maintenance are central components of door reliability and safety.
System architecture Overview Roto E-Tec DoorDrive Cable type SD E-Tec control unit Cable type S Cable junction connection May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
Cable type S length 1 m 637957 Pluggable cable junction, 8-pin (not depicted) 637956 637955 Power supply unit 13 V for Roto E-Tec DoorDrive (not depicted) 637958 Counterplate 60 x 55 x 5 mm incl. screws (not depicted) Subject to change.
If the door is moved at too fast a speed, the swing door drive is actively braked until the door comes almost to a standstill again. May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
Mill out corner connector as far as required only. Make a corresponding corner bracket for reinforcement in the clearance. Set the control to match the Roto configuration. (Refer to page 31). This programming step is best performed in advance, e.g. at the factory.
Installation System overview The following drawing shows an overall view of the system. Cable type SD Roto E-Tec DoorDrive Counterplate E-Tec control unit Cable type S Cable junction connection Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
1) To fasten the door drive in a timber door 20 is replaced by 20a . NOTE! Position 10, 30, 40 and 50 are included in the scope of supply for 637958. May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
Route the cable type SD through the bore in the glazing rebate into the profile chamber. Seal the drill holes to the glazing rebate after routing the cable with vapour diffusion-proof adhesive tape. Drill hole Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
Page 20
Page 18) are located in the centre of the elon- gated holes of the angle bracket. The elongated holes can be used for making positioning correc- tions if the door sash should sag. May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
Page 21
Make sure when inserting, that the the cable type SD is not damaged or kinked. Screw the door drive from the top using 14 fixing screws ( Page 18) onto the door sash. (Tightening torque max. 1.4 Nm) Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
Page 22
Therefore, make sure that they are wired correctly. – Connect to X1 cable type SD to Roto E-Tec DoorDrive. – On X2, connect cable type S to the cable junction. May 2013...
Page 23
/to the spindle drive on cable harness 1 Contact Description Abbreviation Wire colour Motor + Motor – M– Black Hall GND HGND Violet Hall Vcc HVCC Yellow Hall Speed 2 Green Hall Speed 1 Blue Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
Page 24
The two connectors are coded and they cannot be interchanged. Therefore, when connecting the lines make sure that the correct plug-and-socket connector has been selected. Connect cable – using screwdriver (2.5 x 0.4 mm). May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
Page 25
The coupling rod must not be tensioned when it is installed. – The specified wiring must be maintained exactly as stipulated. Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
Wiring Connection diagram for Eneo C / CC with Roto E-Tec DoorDrive DoorSafe Eneo Roto E-Tec DoorDrive Plug-and- socket Black Green connector JST plug- and-socket connector Black White 1 2 3 Access control system Control unit Finger scan, Bluetooth, 7 91112...
Because of the power transfer involved, a wire cross-section of at least 1.5 mm² is recommended. Orientation is provided here by the illustration. Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
Initial operation Initial operation steps Preparation Connect Eneo lock Convert to Roto setting Teach-in closed position Teach-in open position Optional: conduct function test Set up delivery status Initial operation is only possible with the INPOTRON PSU-4351-09 power supply unit. CAuTION!
Page 29
To be conducted by electrics specialist (electrician) only. The default position for the DIP switch is OFF, this position has to be adopted again following every action. Illustration of power supply unit with connection terminals Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
Page 30
Switch on power supply units or plug connector into power socket. Converting to Roto setting Activate Roto settings. To do so, switch on power for control system and set DIP switches to 1111.1010. Confirm by pressing one of the operation mechanisms for 3 seconds.
Illustration of service dongle, the tab acts as a reverse-polarity protection Service interface Service interface illustration Roto settings are available in the tables in bold. These default values are replaced during initial operation in step 3. Individual setting NOTE! All settings denoted by * require a service dongle.
0 0 Feedback on current status – 0 1 Signal when closing: None 1 0 Signal when closing: Output activated for 0.5 seconds 1 1 Signal when closing: Output activated as long as actuation issued Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
If the authorised operation mechanism is used, the authorisa- tion is then cancelled. In other words, the operation mechanism has to be authorised again before each usage. The Roto setting for the authorisation period is one minute. Example: DIP switch set to 01110111 (Roto setting): Following authorisa- tion, the door has to be opened within a period of one minute.
1 0 Reversing on, with continuation after 1 1 0 0 pause 1 1 Reversing off, without continuation after pause 0 1 0 0 Reversing off, with continuation after pause May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
Personal setting 0 0 0 1 Programming the zero position 0 0 1 0 Programming the maximum opening angle 1 1 1 1 1 1 1 0 Resetting to factory settings* Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
ESD: Electro Static Discharge Door electronics: Component on hinge side of door sash, which accom- modates the control system for the Roto E-Tec DoorDrive. Encoding: A text / code is used in a secret translation. Changeable code: Code that changes constantly. A code is valid once only.
Internal safety circuits and external safety circuits managed by the swing door drive are monitored on a cyclical basis. Situations may occur during operation of the Roto E-Tec DoorDrive system that lead to malfunctions. The swing door drive attempts to determine the reasons for this and to re- spond accordingly.
Page 40
= Not to be carried out by the end-user; the end-user may not carry out installation work! = To be carried out either by a specialist company or by the end-user The DIP switches enable the fault memory to be read out. May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
Page 41
Qualified personnel is trained for the following specified work. If, during initial operation, the end user is also given instruction, then the mainte- nance described here can also be performed by the end user. Your Roto specialist dealer will be only too glad to provide you with assistance.
Page 42
– Check the position of the frame and the door sash using a spirit level. – If necessary, have frame adjusted or mounted again by qualified personnel. May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
– Check door hinge or end stop and – if required – have adjusted by quali- fied personnel. – If necessary, use door stopper to limit opening angle. Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
The door manufacturer must ensure that builders and end-users are made aware of the importance of these maintenance instructions. Roto Frank AG recommends that manufac- turers enter into maintenance agreements with their end-users.
Automatic door system user group “Private area” Private area (1 and 2 family home) Regular use for defined and authorised persons, controlled access points, use for instructed and trained persons only. Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
Hazard point between adjacent closing edge and opposite closing edge/wall Risk of impact Risk of crushing Hazard point between adjacent closing edge and floor Risk of impact May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
Risk of being pulled in between the Safety distances are maintained. Distance greater than 25 mm. sash and the ceiling (adjacent closing edge). This must be taken into consideration during the planning phase! Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
Page 48
Risk though operating error Operation of opening/closing func- The door operator is responsible for tion for authorised people only its safe operation. (Operator = “Builder”) instruction of user group (builder, resident) May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change. ...
The operator hereby declares that the residual risks are known, that he is familiar with the installation and operating instructions, that he has received appropriate instruction, and that he will ensure that the user group (builder, resident) receives corresponding instructions. Place, Date Operator signature Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 2013 ...
Page 50
Disposal Both the Roto E-Tec DoorDrive and the packaging consist mainly of raw materials that can be recycled. The Roto E-Tec DoorDrive and the accessories should not be disposed of with domestic waste. Make sure that the old device and any accessories are routed to an appropriate disposal process.
Page 52
Roto Frank AG Window and door technology Wilhelm-Frank-Platz 1 70771 Leinfelden-Echterdingen Germany Telephone +49 711 7598 0 Telefax +49 711 7598 253 info@roto-frank.com www.roto-frank.com From a single source: The optimum hardware system to meet all challenges: Roto Door | Matching hardware technology “for everything to do with doors”...