Sybaritic Dermalife Spa Feng Shui 2G Owner's Manual

Premium hydrospa capsules
Table of Contents

Advertisement

Quick Links

w w w. S y b a r i t i c . c o m
© 2 0 0 8 S y b a r i t i c , I n c . A l l R i g h t s R e s e r v e d
|
2 0 6 3 6 5 R e v. 8 0 9 U F S . 1 0 . 8 0 9 . 7. U

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dermalife Spa Feng Shui 2G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sybaritic Dermalife Spa Feng Shui 2G

  • Page 1 w w w. S y b a r i t i c . c o m © 2 0 0 8 S y b a r i t i c , I n c . A l l R i g h t s R e s e r v e d 2 0 6 3 6 5 R e v.
  • Page 2 952.888.8282 Toll Free 800.445.8418 952.888.8887 Web Site http://www.sybaritic.com E-mail info@sybaritic.com 9220 James Avenue South, Minneapolis, MN 55431 USA S pa F e n g S h u i - Pa g e i 2 0 6 3 6 5 R e v. 8 0 9 U F S . 1 0 . 8 0 9 . 7. U...
  • Page 3 We at Sybaritic, Inc. welcome you as a new owner of a Dermalife Spa Feng Shui 2G System. Enclosed you’ll find your Dermalife Spa Feng Shui 2G System Owner’s, Installation and Service Manual. In it, you’ll find set-up and operating instructions, as well as service and troubleshooting tips. If you have questions, please feel free to contact your Sybaritic Sales Representative or our Customer Service Department.
  • Page 4: Table Of Contents

    Table of Contents SECTION 1 Introduction SECTION 9 Service (Hood) 1.1 Purpose of the Manual 9.1 Removing the Hood Cover 1.2 Customer Service 9.2 Removing the Hood and Changing the Strut Nut 1.3 Disclaimer 9.3 Radiant Heat Emitter 1.4 Copyright 9.4 Speaker 1.5 Warranty 9.5 Temperature Sensor...
  • Page 5: Introduction

    Dermalife ® Spa Feng may exist. Sybaritic, Inc. does not accept responsibility of any ™ Shui 2G System. It may be used as a guide, suitable for all...
  • Page 6: Copyright

    Dermalife Spa Feng Shui 2G System. No attempt has been made to designate as trademarks or service marks all words or terms in which proprietary rights might exist.
  • Page 7: Safety

    Owner’s Manual SECTION 2 | Safety 2 . 2 G E N E R A L A N D U S E R 2 . 1 P R E I N S T A L L A T I O N S A F E T Y T E C H N I C A L S A F E T Y T I P S IN ORDER TO GUARANTEE FULL USER SAFETY THIS UNIT MUST BE...
  • Page 8: Safety Precautions

    Owner’s Manual SECTION 2 | Safety 2 . 4 I M P O R T A N T S A F E T Y 2 . 3 S A F E T Y P R E C A U T I O N S I N S T R U C T I O N S READ AND FOLLOW ALL INSTRUCTIONS Check the unit’s operating voltage before operation.
  • Page 9 Owner’s Manual SECTION 2 | Safety DANGER — Risk of electric shock. Install at least 1.5 m (5 feet) from all metal surfaces. As an alternative, a capsule may be installed within 1.5 m of metal surfaces if each metal surface is permanently connected by a minimum 8.4 mm 2 (8 AWG) solid copper conductor to the wire connector on the terminal box that is provided for this purpose.
  • Page 10: Shipping, Storing & Installation Conditions

    Owner’s Manual SECTION 3 | Shipping, Storing and Installation Conditions 3 . 1 S H I P P I N G , S T O R I N G & I N S T A L L A T I O N C O N D I T I O N S This unit is designed for permanent indoor installation with the following conditions: Temperature of the room: + 59 to + 86°...
  • Page 11: Electrical & Plumbing Requirements

    Because of the special nature of this device, an entire circuit needs to be dedicated to the operation of the Dermalife Spa Feng Shui 2G System. Each individual Dermalife Spa Feng Shui 2G System should have its own dedicated circuit breaker. The current draw depends on the voltage and is rated at 13.41 amps for 220 volts when Radiant Heat and Steam are running.
  • Page 12: Steam Generator Installation Requirements

    Owner’s Manual SECTION 4 | Electrical & Plumbing Requirements 4 . 2 S T E A M G E N E R A T O R I N S T A L L A T I O N R E Q U I R E M E N T S NOTE: Only a qualified/certified/licensed plumber is authorized to make the steam generator connections/installation of this unit strictly according to all local installation.
  • Page 13: Technical Specifications

    Owner’s Manual SECTION 5 | Technical Specifications 5 . 1 T E C H N I C A L S P E C I F I C A T I O N S D I M E N S I O N S Length Width 220 cm (see also page 10)
  • Page 14: Spa Feng Shui ™ 2G System And Its Components

    Owner’s Manual SECTION 5 | Technical Specifications 5 . 2 D E R M A L I F E S PA F E N G S H U I ™ 2 G S Y S T E M A N D I T S C O M P O N E N T S Radiant Emitters &...
  • Page 15: Supplied Accessories

    Owner’s Manual SECTION 4 | Unit Specifications 5 . 4 S U P P L I E D A C C E S S O R I E S Spa Feng Shui 2G System Owner’s Manual 1 Owner’s Manual Client Brochures 1 package of 100 Promotional Poster 1 poster...
  • Page 16: Installation

    Owner’s Manual SECTION 6 | Installation 6 . 1 R E M O V I N G P A N E L S BEFORE ANY REPAIR AND/OR INSPECTION OF THE UNIT, THE ELECTRICAL SUPPLY MUST BE SHUT OFF. BEFORE REMOVING THE SIDE PANEL OF THE UNIT, SHUT OFF THE ELECTRICAL SUPPLY TO THE UNIT. To remove the right side panel, remove screws S1, S2, S3, S5, S6, S7, S8 and S4 (S3 and S4 have two [2] screws on the opposite side panel).
  • Page 17: Removing The Hood

    Owner’s Manual SECTION 6 | Installations 6 . 3 R E M O V I N G T H E H O O D D I S C O N N E C T A L L O T H E R C A B L E S & W I R E S Then open the hood and unscrew strut nuts while keeping the capsule opened.
  • Page 18: Electrical, Dvd & Audio Connection Drawings

    Owner’s Manual SECTION 6 | Installation of Legs 6 . 4 A D J U S T I N G T H E L E G S This unit must be installed on an even, dry surface and levelled by adjusting the unit’s legs. Loosen nut 1.
  • Page 19 SECTION 6 | Installation of Audio To use the Dermalife Spa Feng Shui 2G System with an external audio source (DVD-player, VHS player, general audio system, portable multimedia-player or any other equipment that has a LINE-OUT or EARPHONES output) it is needed to use the red and white/black audio cables to connect it with an external audio source.
  • Page 20: Product Introduction

    Owner’s Manual SECTION 7 | Product Introduction 7 . 1 S PA F E N G S H U I ™ 2 G S Y S T E M The Spa Feng Shui 2G System will greatly enhance your ability to gain additional customers and increase revenue.
  • Page 21 Owner’s Manual SECTION 7 | Features of the Spa Feng Shui 7 . 2 S PA F E N G S H U I 2 G S Y S T E M U N I Q U E F E AT U R E S : The features of your Spa Feng Shui 2G are listed below.
  • Page 22: Water Intake

    Owner’s Manual SECTION 7 | Product Introduction 7 . 3 S P A F E N G S H U I 2 G Knowledge of your client’s contraindications requires a thorough client analysis. Being unaware of their medical history may cause problems. Heart/respiratory problems High blood pressure Kidney disorders...
  • Page 23: Operation

    Owner’s Manual SECTION 8 | Operation 8 . 1 T H E C O N T R O L P A N E L The control panel, which is mounted on the console, is used to ™ operate the Spa Feng Shui 2G System.
  • Page 24: How To Run Your First Warm-Up Session

    Owner’s Manual SECTION 8 | Operation 8 . 2 S P A F E N G S H U I 8 . 4 W O R K I N G W I T H T H E O P E R A T I O N O P T I O N S Set the “Settings”...
  • Page 25 Owner’s Manual SECTION 8 | Operation OPEN AROMA TANK — P R O G R A M S Will empty out all contents from the aroma tank. 01 — High Heat Workout TOTAL TIME — 02 — Natural Cleansing Keeps track of how many hours the Spa Feng 03 —...
  • Page 26 Owner’s Manual SECTION 8 | Operating: Audio, Display Contol, Steam • AUDIO (speaker ON/OFF) • DISPLAY CONTROL (DVD Option) • FACE AIR (10 levels) • COLOR LIGHTS (red, blue, green, turquoise, violet, orange) Fading control (12-60 sec) Manual control • VIBRATION INTENSITY &...
  • Page 27 Owner’s Manual SECTION 8 | Operating: Radiant DryHeat, Vibration and Air Radiant DryHeat Fusion: • To turn Radiant DryHeat Fusion on, simply highlight the Radiant function area using the motion buttons on the control panel (see Figure 1). • ENTER To turn Radiant Heat on/off or to regulate the intensity, press and make your selections.
  • Page 28: Safety Shut Off

    Owner’s Manual SECTION 8 | Operating: Color Lights, Aroma & ON/OFF 8 . 6 S A F E T Y S H U T O F F If the Spa Feng Shui ™ 2G system’s cover is opened during the session, the Steam and Radiant Heat will switch off automatically.
  • Page 29: Service (Hood)

    Owner’s Manual SECTION 9 | Service (Hood) 9 . 1 R E M O V I N G T H E H O O D C O V E R • Required tools: crosshead screwdriver • Remove 2 screws and pull the cover in the direction of the arrow.
  • Page 30: Speaker

    Owner’s Manual SECTION 9 | Service (Heat Emitters & Speaker) Screw Fixing Ring Hood Reflector Reflector Gasket Glass Cover Glass Gasket Screw Spacer Ring Connecting Screw Screw Cap 9 . 4 S P E A K E R ( Figure A. Heat Elements & Ventilators) •...
  • Page 31: Temperature Sensor

    Owner’s Manual SECTION 9 | Service for Sensors and LCD Housing 9 . 5 T E M P E R A T U R E S E N S O R • Required tools: large pliers • The temperature sensor is inserted through the hood and secured with a nut.
  • Page 32: Replacing Parts In The Lcd Housing

    Owner’s Manual SECTION 9 | Replacing Parts in the Housing 9 . 7 R E P L A C I N G P A R T S I N T H E L C D H O U S I N G Face Fan •...
  • Page 33 Owner’s Manual SECTION 9 | Replacing Key Board Upper Control Panel • Required tools: crosshead screwdriver. Removal Remove the connector “KEYB” from the “LCDrb” PCB. Remove 2 screws from the control panel. Installation Install two (2) screws in the control panel. Install the connector to the “KEYB”...
  • Page 34: Service (Bottom)

    Owner’s Manual SECTION 10 | Service 1 0 . 1 R E M O V I N G P A N E L S BEFORE ANY REPAIR AND/OR INSPECTION OF THE UNIT, THE ELECTRICAL SUPPLY MUST BE SHUT OFF. BEFORE REMOVING THE SIDE PANEL OF THE UNIT, SHUT OFF THE ELECTRICAL SUPPLY TO THE UNIT. •...
  • Page 35: On-Off Switch

    Owner’s Manual SECTION 10 | Service 1 0 . 3 O N - O F F S W I T C H The on-off switch breaks electric input when you press it. A temperature increase could cause the unit to automatically shut off.
  • Page 36 Owner’s Manual SECTION 10 | Service 1 0 . 5 V I B R A T O R Y B E D Required tools: Crosshead screwdriver, knife, wire cutters, wire strippers, wire crimper, silicone. The vibration system has three (3) electrical motors. The motors are connected to special nests on the back of the beds. Two (2) motors are located on the upper bed, and one (1) motor is located on the lower bed.
  • Page 37: Hood Switch

    Owner’s Manual SECTION 10 | Service 1 0 . 6 H O O D S W I T C H 1 0 . 8 S T E A M G E N E R A T O R Required tools: NOTE: Wrench 7mm When you are working with the steam generator always...
  • Page 38: Replacing The Thermal Fuse

    Owner’s Manual SECTION 10 | Service 1 0 . 1 0 R E P L A C I N G T H E T H E R M A L F U S E Required Tools: Small flat screwdriver, 10 mm wrench. Removal •...
  • Page 39: Advanced Electronics & Troubleshooting

    Owner’s Manual SECTION 11 | Advanced Electronics & TroubleShooting 1 1 . 1 E L E C T R I C A L C O N N E C T I O N S All ports in PCB are numbered. Their cable number and description are in the following table. Port No.
  • Page 40 Owner’s Manual SECTION 11 | Advanced TroubleShooting 1 1 . 2 T R O U B L E S H O O T I N G Always try to restart the capsule before any troubleshooting. LCD Display Error Messages M E S S A G E T R I G G E R P R O B A B L E C AU S E C O R R E C T I V E A C T I O N...
  • Page 41 Owner’s Manual SECTION 11 | Advanced TroubleShooting M E S S A G E T R I G G E R P R O B A B L E C AU S E C O R R E C T I V E A C T I O N WATER TANK Spa Steam Water tank is full...
  • Page 42: Troubleshooting

    Owner’s Manual SECTION 11| Advanced TroubleShooting Remedy R E M E D Y Eliminate conditions listed below. Refer to section 11.5 – Cleaning the steam generator. Repeat cleaning process 3 times if problem persists. Run any pre-set program to verify unit performance. Repeat cleaning process 3 times if problem persists.
  • Page 43: System Cleaning Maintenance & Reinstallation

    ™ 2G System must be cleaned and disinfected using a pre-tested, pre-approved cleaning solution sold by Sybaritic called Accel TB .05% solution. Accel offers a new technology within this disinfectant, based on Cleaning instructions using Accel Solution are as follows: an active ingredient known as “Accelerated Hydrogen Peroxide...
  • Page 44: Cleaning The Shell

    Owner’s Manual SECTION 12 | System Cleaning, Maintenance & Reinstallation 1 2 . 2 C L E A N I N G T H E S H E L L Your Spa Feng Shui 2G System is shipped to you wrapped carefully NOTE: Cleaning after each use removes oils, perspiration and in clear plastic wrap.
  • Page 45 Owner’s Manual SECTION 12 | System Cleaning, Maintenance & Reinstallation 1 2 . 7 C L E A N I N G T H E S Y S T E M D R A I N ( L O C A T E D U N D E R T H E U P P E R V I B R A T O R Y B E D ) Recommended to be completed nightly:...
  • Page 46 S P A F E N G S H U I ™ 2 G S Y S T E M Serial No.: Micro Controller Identification No.: USA HEADQUARTERS: DISTRIBUTED BY: SYBARITIC, INC. 9220 JAMES AVENUE SOUTH MINNEAPOLIS, MN 55431 USA Tel: (952) 888-8282 Fax: (952) 888-8887...
  • Page 47: Owner's Registration Form

    S P A F E N G S H U I ™ 2 G O W N E R ’ S R E G I S T R A T I O N F O R M Please FAX or SEND this Registration Form to Sybaritic.
  • Page 48 This One Year Product Warranty will expire 12 months from the Original Purchase Invoice Date. General Terms and Conditions Sybaritic, Inc. (hereinafter “SYB”) agrees to provide warranty service according to the terms and conditions set forth in this document. ACTIVATION: This Product Warranty shall become effective upon the original purchase date on the invoice.
  • Page 49 Owner’s Manual APPENDIX C | Product Warranty CUSTOMER’S RESPONSIBILITES: The Customer is responsible to: Maintain the equipment in an environment suitable for the operation of the equipment as instructed in the applicable Operator’s Manual. Maintain the proper electrical power requirements as recommended by SYB. Follow all operating instructions as indicated in the applicable Operator’s Manual supplied by SYB.
  • Page 50 SYB. The provisions of this Product Warranty are binding upon all successors, administrators, trustees and permitted assigns of Customer. This Product Warranty may not be amended, altered or changed. How to Obtain Product Warranty Service Contact Sybaritic Technical Service Department at: Telephone: (800) 445.8418 or (952) 888.8282 Fax: (952) 888.8887...
  • Page 51 Service will provide the Owner with a Return Goods Authorization Number for the return. Return parts not received by Sybaritic, Inc. within 30 Days will constitute cause for invoicing of the replacement parts to the Product Warranty and Extended Warranty Owners at list price.
  • Page 52 Owner’s Manual APPENDICES D | Device Pre-Set Program Charts (1-10) Spa Feng Shui P R E - S E T P R O G R A M S C H A R T S A P P E N D I X D Note: These pre-set program charts should be used with the program version specified in this document.
  • Page 53: Device Pre-Set Program Charts D

    Owner’s Manual APPENDIX D | Device Pre-Set Program Charts D E V I C E P R E - S E T P R O G R A M C H A R T S Program 1 – High Heat Workout Radiant heat fans continue working for a few minutes after the program ends.
  • Page 54 Owner’s Manual APPENDIX D | Device Pre-Set Program Charts Program 2 – Natural Cleansing Radiant heat fans continue working for a few minutes after the program ends. If the steam is working, the radiant heat elements are automatically switched into the lowest level. S pa F e n g S h u i - A p p e n d i x D 2 0 6 3 6 5 R e v.
  • Page 55 Owner’s Manual APPENDIX D | Device Pre-Set Program Charts Program 3 – Stress Release Radiant heat fans continue working for a few minutes after the program ends. If the steam is working, the radiant heat elements are automatically switched into the lowest level. S pa F e n g S h u i - A p p e n d i x D 2 0 6 3 6 5 R e v.
  • Page 56 Owner’s Manual APPENDIX D | Device Pre-Set Program Charts Program 4 – Rejuvenation Radiant heat fans continue working for a few minutes after the program ends. If the steam is working, the radiant heat elements are automatically switched into the lowest level. S pa F e n g S h u i - A p p e n d i x D 2 0 6 3 6 5 R e v.
  • Page 57 Owner’s Manual APPENDIX D | Device Pre-Set Program Charts Program 5 – Relief Radiant heat fans continue working for a few minutes after the program ends. If the steam is working, the radiant heat elements are automatically switched into the lowest level. S pa F e n g S h u i - A p p e n d i x D 2 0 6 3 6 5 R e v.
  • Page 58 Owner’s Manual APPENDIX D | Device Pre-Set Program Charts Program 6 – Smoothing Radiant heat fans continue working for a few minutes after the program ends. If the steam is working, the radiant heat elements are automatically switched into the lowest level. S pa F e n g S h u i - A p p e n d i x D 2 0 6 3 6 5 R e v.
  • Page 59 Owner’s Manual APPENDIX D | Device Pre-Set Program Charts Program 7 – Revive Radiant heat fans continue working for a few minutes after the program ends. If the steam is working, the radiant heat elements are automatically switched into the lowest level. S pa F e n g S h u i - A p p e n d i x D 2 0 6 3 6 5 R e v.
  • Page 60 Owner’s Manual APPENDIX D | Device Pre-Set Program Charts Program 8 – Meditation/Dry Wrap Radiant heat fans continue working for a few minutes after the program ends. If the steam is working, the radiant heat elements are automatically switched into the lowest level. S pa F e n g S h u i - A p p e n d i x D 2 0 6 3 6 5 R e v.
  • Page 61 Owner’s Manual APPENDIX D | Device Pre-Set Program Charts Program 9 – Steam Body Wrap Radiant heat fans continue working for a few minutes after the program ends. If the steam is working, the radiant heat elements are automatically switched into the lowest level. S pa F e n g S h u i - A p p e n d i x D 2 0 6 3 6 5 R e v.
  • Page 62 Owner’s Manual APPENDIX D | Device Pre-Set Program Charts Program 10 – Awakening Radiant heat fans continue working for a few minutes after the program ends. If the steam is working, the radiant heat elements are automatically switched into the lowest level. S pa F e n g S h u i - A p p e n d i x D 2 0 6 3 6 5 R e v.
  • Page 63 © 2 0 0 8 S y b a r i t i c , I n c . A l l R i g h t s R e s e r v e d | 2 0 6 3 6 5 R e v. 8 0 9 U F S . 1 0 . 8 0 9 . 7. U SYBARITIC, INC. Global Aesthetic Solutions 9220 James Avenue South Minneapolis, Minnesota 55431 USA www.sybaritic.com...