Advertisement

Quick Links

user manual
EvoBoost

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYDRO EvoBoost and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dover HYDRO EvoBoost

  • Page 1 user manual EvoBoost...
  • Page 2: Table Of Contents

    contents contents introduction Overview safety description contents of packaging dimensions and specifications installation 5.1 Site surveys and installation requirements 5.2 Installation for up to 3x EvoClean dispensers set up operation maintenance troubleshooting 10. spares and repair warranty 12. decommissioning and disposing electrical approvals water approvals WEEE - waste electrical &...
  • Page 3: Introduction

    introduction Please look at and read these instructions carefully before starting installation and operation. Keep the Installation and User Manual for future reference. Remove all packaging and check the EvoBoost for damage or missing parts, against the Contents of Packaging, before starting installation.
  • Page 4: Safety

    1. safety Safety Precautions THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS. TO AVOID SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE: WARNING • please use this equipment carefully and observe all warnings and cautions as detailed within this manual before installation or operation of this equipment. •...
  • Page 5: Description

    2. description Water inlet Water outlet Power cable 3M (10ft) long Pump Overflow fitting Rear cover Water tank The EvoBoost is designed to supply laundry dispensers (max. 3 low flow EvoClean’s) with 2.5 bar (35 psi) consistently. With the EvoBoost installed, chemical delivery will be consistent and extremely accurate, leading to predictable laundry results.
  • Page 6: Contents Of Packaging

    3. contents of packaging Packaging contains: Item Description EVB1561230VB EVB1561115VG EvoBoost Strainer Washer 15mm Double Check Valve Waste Pipe Elbow • For installation kits and spare parts please see page 17 4. dimensions & specifications Model Power Current Appliance Operating Inlet Outlet Inlet...
  • Page 7: Installation

    [19.5] [10.4] 264.6 5. installation 5.1 Site services and installation requirements Safety • Please read section 1 – Safety, carefully, prior to installation, to ensure all precautions have been adhered to. • The unit must be installed by a trained Engineer. •...
  • Page 8: Installation For Up To 3X Evoclean Dispensers

    5.2 Installation for up to 3x EvoClean dispensers The following installation suggestions outline the method of connecting the EvoBoost to the mains water supply & up to 3 x EvoClean units. A range of installation kits can be purchased to assist with a quick, neat & professional installation, that achieve the 3 options listed below.
  • Page 9 1x EvoClean EVB1561230VB 230V BSP Max horizontal distance from Point “A” to Point “B” is 3m (10ft) 4/2a CONNECT OVERFLOW TO DRAIN WATER MAIN WATER FILTER (105 MICRON) CUSTOMER SUPPLIED 2x EvoClean EVB1561230VB 230V BSP Max horizontal distance from Point “A” to Point “B” is 3m (10ft) 4/2a CONNECT OVERFLOW...
  • Page 10 3x EvoClean EVB1561230VB 230V BSP Max horizontal distance from Point “A” to Point “B” is 3m (10ft) 4/2a CONNECT OVERFLOW WATER MAIN TO DRAIN WATER FILTER (105 MICRON) CUSTOMER SUPPLIED 1 x EvoClean EVB1561115VG 115V GHV Max horizontal distance from Max distance from Point "A"...
  • Page 11 2x EvoClean EVB1561115VG 115V GHV Max horizontal distance from Max distance from Point "A" Point “A” to Point “B” is 3m (10ft) to Point "B" is 12 Ft (3.5 M) 4/2a WATER MAIN CONNECT OVERFLOW TO DRAIN WATER FILTER (105 MICRON) CUSTOMER SUPPLIED 3x EvoClean EVB1561115VG 115V GHV Max horizontal distance from...
  • Page 12 5.3 Electrical connection • All electrical work should be carried out by a qualified Electrician, in accordance with local and national regulations. • Isolate power & water supply to this equipment before connection / disconnection of water connections and / or maintenance on this unit and / or dispensers supplied by this unit. •...
  • Page 13: Set Up

    6. set up EvoBoost Plumbing and power has been correctly connected according to the installation section. Once this is complete: • Open the isolation valve connecting the EvoBoost to the water main. • Allow the EvoBoost water reservoir to fill (this can take up to 15 minutes depending on water inlet flow). •...
  • Page 14: Operation

    7. operation Operating the EvoClean dispensers Once the EvoBoost has been setup (as per setup section), the EvoClean units will be ready to operate in a wash cycle. The EvoBoost will automatically run every time the EvoClean operates, through use of a built-in pressure switch. The EvoBoost will shut off automatically once the EvoClean unit stops dosing.
  • Page 15 Clean pickup tube, removing any film, particles, dirt that Clean inside of tank and lower the pickup tube back into may have built up. the tank WARNING TAKE CARE NOT TO DROP THE PICKUP HOSE INTO THE WATER TANK Replace securing clip back onto pickup tube WARNING TAKE CARE NOT TO DROP THE SECURING CLIP INTO Replace rear cover THE WATER TANK...
  • Page 16: Troubleshooting

    9. troubleshooting Error Possible Cause Possible Resolution • Pump running is much louder than • Pump pickup tube possibly • Follow maintenance procedure for usual blocked cleaning pickup tube & cleaning tank • Pump running intermittently • Excess backpressure in the •...
  • Page 17 10. spares & accessories Install kits Install kits are available for both 115V and 230V versions, reference the table below against the part images: Install kit for X number of EvoClean Dispensers 230v BSP Version 115v GH Version 1x EvoClean 2x EvoClean 3x EvoClean 1x EvoClean 2x EvoClean 3x EvoClean Description HYD10099195 HYD10099196 HYD10099197 HYD10099188 HYD10099189 HYD10099190 ¾...
  • Page 18: Warranty

    Maintenance kit The following maintenance kit is available, which allows the correct maintenance regime to be followed as detailed in this manual: 1x pickup tube assembly 1x washer strainer 11. warranty Seller warrants solely to Buyer the Products will be free from defects in material and workmanship under normal use and service for a period of one year from the date of completion of manufacture.
  • Page 19: Water Approvals

    14. Water Approvals Hydro Systems EvoBoost has certified UK WRAS Approval. Certificate Number: 1908742 This product has been tested and found to comply with the requirements of the Water Supply (Water Fittings) Regulations 1999 for England and Wales, theWater Byelaws 2014, Scotland and the Water Regulations Nothern Ireland. This product is certified as suitable for backflow prevention against fluid category 4, with a maximum working pressure 6.0 bar and has been certified for cold water use only.
  • Page 20 Hydro Systems Company Americas +1 513-271-88OO contact-hydro@hydrosystemsco.com www.hydrosystemsco.com Europe +44 O1344 48888O info@hydrosystemseurope.com www.hydrosystemseurope.com Asia Pacific +86 21-6187-1O3O sales.hydro@hydrosystemschina.com www.hydrosystemschina.com...