  • Page 10 PAW-TG20C1E3STD PAW-TG20C1E3HI PAW-TG30C1E3STD PAW-TG30C1E3HI NÁVOD K OBSLUZE PAW-TG30C2E3STD PAW-TG40C1E3STD BRUGSANVISNING GEBRAUCHSANWEISUNG ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ INSTRUCTIONS FOR USE INSTRUCCIONES DE USO KÄYTTÖOHJE NOTICE D'UTILISATION HASZNÁLATI ÚTMUTATÓ ISTRUZIONI PER L'USO GEBRUIKSAANWIJZING BRUKERVEILEDNING INSTRUKCJA OBSŁUGI INSTRUÇÕES PARA UTILIZAÇÃO BRUKSANVISNING www.aircon.panasonic.eu...
  • Page 11 WARNINGS The appliance may be used by children aged 8 and older and persons with physical, sensory or mental disabilities or lacking experience or knowledge, if they are under supervision or taught about safe use of the appliance and if they are aware of the potential dangers. Children should not play with the appliance.
  • Page 12: Installation

    øJ 1 Cold water inflow 2 Medium outlet from the heat exchanger 3 Circulation conduit 4 Medium inflow into the heat exchanger 5 Hot water outflow PAW-TG20C1E3STD PAW-TG20C1E3HI PAW-TG30C1E3STD PAWTG30C1E3HI PAWTG40C1E3STD 1535 1675 1590...
  • Page 13 øJ 1 Cold water inflow 2 Medium outlet from the heat exchanger 3 Circulation conduit 4 Medium inflow into the heat exchanger 5 Hot water outflow PAWTG30C2E3STD 1450 1205 G5/4 G 3/4 G5/4 Image 2: Connection and installation dimensions of the storage tank [mm]...
  • Page 14: Connection To The Water Supply

    CONNECTION TO THE WATER SUPPLY Connection to water supply should be made according to the markings for the connections, as defined in the previous Chapter. For safety reasons the supply pipe must be fitted with a safety valve or, alternatively, a valve of the safety class that prevents the pressure in the tank from exceeding the nominal pressure by more than 0.1 MPa (1 bar).
  • Page 15: Electric Connection Scheme

    ELECTRIC CONNECTION SCHEME Terminals on the inner side Connection cable Short circuit Storage tank temperature sensor 3-way reversing valve Caution! +°C Internal circuitry should not be changed! Green/ Brown Blue Orange Grey yellow N PE Valve active Valve not active AB - A AB - B Open for heating...
  • Page 16: Installation Of Sensors

    INSTALLATION OF SENSORS On the upper side of the storage tank there are two sensor tubes for mounting the sensors for regulation of the system connection of the hot water storage tank to other heating sources. The maximum diameter of the sensors is 8 mm. Long sensor tube (lower tank position) Short sensor tube (upper tank position) Image 5: Installation of sensors...
  • Page 17: Use And Maintenance

    USE AND MAINTENANCE The hot water storage tank is ready for use once it has been connected to water and electricity and other heating sources. The usual main sources for heating domestic water are central heating or solar power; in this case any regulation of water heating is performed in the heating system.
  • Page 18 TECHNICAL CHARACTERISTICS OF THE APPLIANCE Type PAW-TG20C1E3STD PAW-TG20C1E3HI PAW-TG30C1E3STD Energy efficiency class Standing loss S 70,8 58,8 88,8 Storage volume Rated pressure [MPa (bar)] 0,6 (6); 0,9 (9); 1,0 (10) Weight/filled with water [kg] 97 / 282 115 / 305...
  • Page 19 PAW-TG20C1E3STD PAW-TG20C1E3HI PAW-TG30C1E3STD PAW-TG30C1E3HI PAW-TG30C2E3STD PAW-TG40C1E3STD 08/2015 512561...