Clever OV1000 User Manual

Height adjustable table

Advertisement

Quick Links

OV1000 |
Part No. 23624
OV1000
HEIGHT ADJUSTABLE TABLE
USER GUIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OV1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Clever OV1000

  • Page 1 OV1000 | Part No. 23624 OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE...
  • Page 2 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout the day. Our OV1000 table is the industry standard in height-adjustable products, and your first step towards improving the efficiency and well-being of your organization.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS User Guide: OV1000 TABLE OF CONTENTS Parts Diagram Full Length Independent Independent with HAT Channel Three-Leg: 90 Degree Three-Leg: 120 Degree Safety Information 9-10 Assembly Instructions 11-17 18-19 Operation Initialization and Reset Handswitch Operation Programmable Handswitch Operation...
  • Page 4: Parts Diagram

    PARTS DIAGRAM User Guide: OV1000 OV1000 PARTS DIAGRAM FULL LENGTH For tables up to 84" PARTS Qty/Package 1. Beam 2. Column 3. Top Support 4. Foot 5. M8x1.25 12mm Self-Threading Screw 8 6. M10x1.5 30mm Screw Handswitch DO NOT remove the foam surrounding the motor.
  • Page 5: Independent

    PARTS DIAGRAM User Guide: OV1000 INDEPENDENT For tables 60" or Less PARTS Qty/Package 1. Independent Beam 2. Column 3. Top Support 4. Foot 5. M8x1.25 12mm Self-Threading Screw 8 6. M10x1.5 30mm Screw Handswitch DO NOT remove the foam surrounding the motor.
  • Page 6: Independent With Hat Channel

    PARTS DIAGRAM User Guide: OV1000 INDEPENDENT WITH HAT CHANNEL For tables 60"−84" PARTS Qty/Package 1. Independent Beam 2. Column 3. Top Support 4. Foot 5. HAT Channel 6. M8x1.25 12mm Self-Threading Screw 8 M10x1.5 30mm Screw 8. Handswitch DO NOT remove the foam 9.
  • Page 7: Three-Leg: 90 Degree

    PARTS DIAGRAM User Guide: OV1000 THREE-LEG: 90 DEGREE For tables up to 72" PARTS Qty/Package 1. Support Beam 2. Independent Beam 3. M8x1.25 12mm Self-Threading Screw 12 4. Top Support 5. Column 6. Foot M10x1.5 30mm Screw 8. #10-15 " Screw DO NOT remove the foam 9.
  • Page 8: Three-Leg: 120 Degree

    PARTS DIAGRAM User Guide: OV1000 THREE-LEG: 120 DEGREE For tables up to 60" PARTS Qty/Package 1. Support Beam 2. Independent Beam 3. M8x1.25 12mm Self-Threading Screw 12 4. Top Support 5. Column 6. Foot M10x1.5 30mm Screw 8. #10-15 " Screw DO NOT remove the foam 9.
  • Page 9: Safety Information

    SAFETY INFORMATION User Guide: OV1000 SAFETY INFORMATION IMPORTANT SAFETY INSTRUCTIONS Save these instructions. DANGER To reduce the risk of electric shock: Always unplug this furnishing from the electrical outlet before cleaning. WARNING: To reduce the risk of death, serious injury, or property damage, read and follow this safety information and the provided instructions when assembling this product.
  • Page 10 SAFETY INFORMATION User Guide: OV1000 DO NOT OVERLOAD DESK To prevent table from tipping or collapsing, make sure the desk frame is not overloaded by the weight of tabletop and objects on table. Evenly distribute load; excess loads near edges can reduce stability and lead to tip over.
  • Page 11: Assembly Instructions

    The assembly of the table frame to be made in accordance with this manual. Changes to the table frame or improper use may affect the safety, function, and life of your product. This manual is for all sit-stand tables from the OV1000 series. Due to different models or types, pictures may vary.
  • Page 12 ASSEMBLY INSTRUCTIONS User Guide: OV1000 (FOR INDEPENDENT BEAMS ONLY) FASTEN THE TOP SUPPORTS ONTO THE TABLE TOP Be sure top supports are mounted 1.5" from edge of work surface. ASSEMBLE THE BEAM AND COLUMN TO THE TOP SUPPORT ILLUSTRATION A...
  • Page 13 ASSEMBLY INSTRUCTIONS User Guide: OV1000 ILLUSTRATION B ASSEMBLE THE FOOT TO THE COLUMN Assemble using the M10x1.5 x 30mm length screws (2 per column). The maximum tightening torque for these screws is 48Nm. (35 lbs-ft). OV1000 | 13...
  • Page 14: Assembly Instructions

    ASSEMBLY INSTRUCTIONS User Guide: OV1000 FASTEN THE TABLE FRAME ONTO THE TABLE TOP Be sure to use approved screws per the table top supplier. FULL LENGTH INDEPENDENT 1.5 in INDEPENDENT WITH HAT CHANNEL Note: Feed the motor cables through the HAT channel before attaching the HAT channel to the top support and column.
  • Page 15: Assembly Instructions

    ASSEMBLY INSTRUCTIONS User Guide: OV1000 THREE-LEG: 90 DEGREE TOP SIZE 3.9in 3.4in 24in 30in 14in TABLE LENGTH 72in 3.9in 3.4in 8.7in 45° THREE-LEG: 120 DEGREE TABLE DEPTH 24in 24in 30in 30in TABLE LENGTH 60in 3.4in 120° 1.9in 30° 21.9in OV1000 | 15...
  • Page 16 ASSEMBLY INSTRUCTIONS User Guide: OV1000 FASTEN THE CONTROL BOX AND HANDSWITCH TO THE TABLE TOP Make sure the control box and handswitch are fastened in a location where all the cables will connect without being in tension. Be sure to use approved screws per the table top supplier.
  • Page 17: Operation

    ASSEMBLY INSTRUCTIONS User Guide: OV1000 CONNECT THE HANDSWITCH (HS) CABLE TO THE CONTROL BOX CONNECT THE SUPPLIED POWER CORD (AC) TO THE CONTROL BOX ATTACH ALL CABLES TO THE TABLE TOP Attach cables in order to avoid any damage during operation.
  • Page 18: Handswitch Operation

    OPERATION INFORMATION User Guide: OV1000 OPERATION INFORMATION INITIALIZATION/RESET The desk must be initialized/reset after any of the following: - After assembly - After disconnection from the power supply - After any impact on the table top. To initialize/reset, move the table to the lowest position by pressing the DOWN button on the handswitch until the columns reach the lowest position.
  • Page 19: Change The Height Unit

    OPERATION INFORMATION User Guide: OV1000 PROGRAMMABLE HANDSWITCH OPERATION (continued) CHANGE THE HEIGHT UNIT (inches or centimeters) The handswitch can display the table height in either centimeters or inches. With the help of the S5-menus, the unit of measure can be changed.
  • Page 20: Troubleshooting

    TROUBLESHOOTING User Guide: OV1000 TROUBLESHOOTING UNIT ERROR CODE SOURCE SOLUTION No power supply Plug in the power cord or check the connection Table does not on the control box move No connection or a loose Verify the plug connections of the motor cable...
  • Page 21: Troubleshooting

    TROUBLESHOOTING User Guide: OV1000 HANDSWITCH DISPLAY ERROR CODE SOURCE SOLUTION The control box monitors the duty cycle (time-controlled) and its max Wait until the “HOT” display goes out - the table is working properly again temperature. A value has been exceeded.
  • Page 22: Technical Data

    TECHNICAL DATA User Guide: OV1000 TECHNICAL DATA GENERAL CONTROL BOX Power supply 120 VAC ±10% / 60 Hz Standby power consumption, primarily <0.3 W Operating temperature 0-35°C Protection class IP 20 Maximum power output 216VA/24V TWO-COLUMN FRAME WITH CONTROL BOX Maximum lift capacity 200 lb (≈...
  • Page 23: Warranty

    CUSTOMER SERVICE User Guide: OV1000 STANDARDS & CERTIFICATIONS The drive system is tested according to the following standards: UL 962 Issued: 2014/11/07 Ed: 4 Household and Commercial Furnishings CSA C22.2#68 Issued: 2009/09/01 Ed: 7 (R2014) Motor-Operated Appliances (Household and Commercial) Meets BIFMA X5.5 2014.
  • Page 24 OV1000 USER GUIDE Part No. 23624 Rev I | 061919...