Lennox LZP-4 Installation Instructions Manual page 5

Zone control panel
Hide thumbs Also See for LZP-4:

Advertisement

Installation (continued)
6. Install the thermostats. Refer to the instructions
provided with the thermostat.
18 AWG thermostat wire minimum recommended.
CONTROL PANEL
SET-UP
DIP SWITCH
POSITIONS
Any Zone,
HEAT/COOL
Heat Cool
Zone 1,
HEAT/COOL
Heat Cool
Any Zone,
Heat Pump,
HEAT/COOL
Aux Heat Timer > 0
Zone 1,
HEAT/COOL
Heat Pump
Any Zone,
Heat Pump,
HEAT PUMP
Electric,
Aux Heat Timer = 0
Any Zone,
Heat Pump,
HEAT PUMP
Gas,
Aux Heat Timer = 0
TABLE 2 – THERMOSTAT REQUIREMENTS
ZONE 1
Terminals
Type
(see Tables 2a & 2b)
R, C, W, Y, G
Optional: W2 and Y2
R, C, W, Y, G, O, B
Optional: W2 and Y2
R, C, W, Y, G
Optional: W2 and Y2
R, C, W, Y, G, O, B
Optional: W2 and Y2
R, C, W1, Y1, G, O
Optional: Y2
R, C, W1, Y1, G, O
Optional: Y2
Thermostat Selection Guide
The position of the HEAT PUMP / HEAT/COOL switch,
the ZONE 1 / ANY ZONE switch and the AUX.
MINUTES switch (see DIP Switch Settings section) will
determine the thermostat requirements for each zone.
Any 24-volt electronic thermostat with a "C" (24VAC
common) connection can be used. Do not use
mechanical or power robbing thermostats. Power
robbing thermostats can cause unintended operation –
DO NOT use power robbing thermostats. Use Table 2
to determine which thermostat is required:
Recommended
Thermostats
Type
(see Table 2c)
1, 2
HEAT/COOL
3, 4, 7
1, 2
HEAT/COOL
3, 4, 7
1, 2
HEAT/COOL
3, 4, 7
1, 2
HEAT/COOL
3, 4, 7
8
HEAT PUMP
5, 6
5, 6
HEAT PUMP
5, 6
Page 5
ZONES 2-4
Recommended
Terminals
Thermostats
(see Tables 2a & 2b)
(see Table 2c)
R, C, W, Y, G
Optional: W2 and Y2
R, C, W, Y, G
Optional: W2 and Y2
R, C, W, Y, G
Optional: W2 and Y2
R, C, W, Y, G
Optional: W2 and Y2
R, C, W1, Y1, G, O
Optional: Y2
R, C, W1, Y1, G, O
Optional: Y2
1, 2
3, 4, 7
1, 2
3, 4, 7
1, 2
3, 4, 7
1, 2
3, 4, 7
8
5, 6
5, 6
5, 6