Physiolaser olympic 500 Contents General Notes ......................3 Physiolaser principle of function .................. 3 Safety standard ......................4 Safety Precautions ....................... 5 Device out of use......................5 Description of the Device / Proper Usage ..............6 Technical data ......................6 Content of delivery .......................
Physiolaser olympic 500 General Notes These operating instructions must be read carefully before starting the device. These operating instructions describe the correct usage of the Physiolaser olympic and also point out any potential risks. These operating instructions are to be read and observed by all persons who operate, use, service and inspect the device.
Physiolaser olympic 500 Safety standard The Physiolaser olympic is a high-quality, microprocessor-controlled, multi-function device. It combines a high-output, universal therapy laser with a diagnostic device for measuring skin conductance values. The Physiolaser olympic software offers users a wide range of application possibilities.
Physiolaser olympic 500 Safety Precautions Caution - Using the operating equipment or settings in a way not described here can result in dangerous exposure to radiation. Shutdown in an emergency The laser can be shut down in the event of an emergency by pressing the Emergency button or by pulling out the safety plug.
Physiolaser olympic 500 Description of the Device / Proper Usage Technical data Laser therapy device for mobile and local use Physiolaser olympic 500 Laser class Protection class IP 21 (drop proof) Absolute failure of the measurement of the laser power Modulation frequency 0,1 Hz - 18 688 Hz (±...
Physiolaser olympic 500 Proper usage and field of application The Physiolaser is a therapeutic medical device which is to be used exclusively in medical offices, clinics and rehab centers, and should only be operated under constant supervision. The Physiolaser is designed for a veterinary therapy, treatment of wounds, joints and pain.
Physiolaser olympic 500 Precautions Patients may suffer an exacerbation of symptoms after laser therapy in conjunction with a recent steroid injection. For this reason laser should not be used within 2-3 weeks of a recent steroid injection on or near the same site.
Physiolaser olympic 500 Explanation of the pictograms Equipment rating against harmful ingress of water as defined in IEC529. (see std. 60601-1 clause 6.1(L) ) IP21 Protection against electric shock regarding allowable leakage current limitations are specified in standard 60601-1. The device meets the requirements of 93/42/EEC for medical products.
Physiolaser olympic 500 Location of the labels Front panel: Symbol for the laser beam ”Warning for laser beam”. Left: Explanatory Label Symbol (International): "Laser radiation" including the standard which was used for the classification of the laser. Right: Label indicating technical data, serial number and address of the manufacturer.
Physiolaser olympic 500 Sockets and connections on the front cover and probe Slot for the memory card Display Key switch Remote laser stop LaserTest Emergency stop Frequency Current connected group Sockets for the laser probe Socket for the Laser start/stop...
Physiolaser olympic 500 LED indicator, display Main unit Display and LED Color Status Meaning Buttons blue Buttons are ready for use Buttons yellow Button is active Stand-by yellow Show Stand-by or Ready mode Ready Laser data blue Connected probe is recognized but not active...
Physiolaser olympic 500 Display after starting the device with the Key switch Indicates the Stand by mode Pre settings, manufacturer´s data, version no., Ready (therapy mode), frequency Language setting. selection, laser setting, diagnosis Touching the buttons on the display will activate the functions.
Physiolaser olympic 500 Button functions on the display (yellow color shows active function) Display after pressing the Ready button. Active buttons are yellow, inactive blue. Upper buttons are corresponding with the frequency groups , thereafter frequency rows and single frequencies.
Page 17
Physiolaser olympic 500 Frequency selection: BAHR1 Frequency 5´ for the multi-cluster probe. Frequency selection: BAHR2 Hysteria frequency for the multi-cluster probe Frequency selection: Chakra 1-8 acc. to BAHR Sexual Chakra Version 1.4 June 2007...
Page 18
Physiolaser olympic 500 Frequency selection: Chakra 9-15 acc. to BAHR Protection Chakra Frequency selection: Meridian 1 acc. REININGER Small Intestine. Frequency selection: Meridian 2 acc. REININGER Liver. Frequency selection: Reininger Reininger 1 RI 2 Reininger I to II have a similar display design.
Page 19
Physiolaser olympic 500 Frequency selection: Reininger Level 2 K-HWP Frequency selection: Reininger Anti-Freq. 2 Anti inflammation Frequency selection: Reininger Viral/Bacterial Anti viral Version 1.4 June 2007...
Page 20
Physiolaser olympic 500 Frequency selection: Therapy program General 1 Nerves Available rows: General 1 and 2 Orthopaedics Derma Dental The mix button is not available for the therapy programs. Frequency selection: Free Frequency Free Freq. 6 Available are 10 memories each with 11 spaces.
Physiolaser olympic 500 Pre-settings, default setting In the service menu you will find the settings for language, Laser Tester and usage meter and information about the version number, software updates, manufacturer. Setup menu with information of the manufacturer and options for:...
Page 22
Physiolaser olympic 500 Pre-setting: Usage meter with additional coding Pre-setting: Activation and changing the sensibility of the Laser Test on the front panel. Pre-setting: Information about software updates. Version 1.4 June 2007...
Physiolaser olympic 500 Starting operation Placement of the unit Choose a strong and horizontal table to place the unit, if it is not in the portable use. olympic in an optimal condition for the use. Expand the legs to position the...
Page 24
Physiolaser olympic 500 Condition of the battery, charging the battery On the lower left side of the display on front panel you will find a bar indicating the condition of the battery. If it is fully green, the battery is sufficiently charged. If turns to yellow and red, please recharge the battery or use mains current supply.
Physiolaser olympic 500 Operational modes The Physiolaser olympic will indicate 3 modes of operation: Standby, Ready, Power- save. After switching on the Physiolaser olympic the condition of the battery and contact to the mains current supply will be checked, thereafter the Physiolaser olympic will control if any probe is connected and will identify the probe.
Physiolaser olympic 500 Selecting the settings for the laser probe: Power, Energy, Time Press any of the fields Power, Energy or Time and type in the new data on the number pad. Store with “Enter” and go back to the Ready mode by pressing the button “Therapy”.
Page 27
Physiolaser olympic 500 The yellow field will indicate the active laser probe. R= reduced power. Display message on the laser probe Frequency symbol Frequency in Hz Supplied energy in Joule A´ 292.00 03.12 02:14 Battery Laser power Expired therapy time Laser power indication <...
Physiolaser olympic 500 Pilot beam, laser control LED on the probes The red pilot diodes in the probe head indicate the direction of the invisible laser beam (pilot beam) within 2 seconds before the laser starts. Probes with multiple laser diodes...
Physiolaser olympic 500 Laser Test To test the laser radiation, simply beam to the sensor (IR-TEST) on the front panel, you will hear a sound if the laser is active. NOGIER/BAHR program The NOGIER/BAHR programme contains modulations frequencies according to Dr. Paul Nogier, France and Dr.
Physiolaser olympic 500 REININGER program The Reininger programme contains modulations frequencies according to Dr. Manfred Reininger, Austria. Reininger I Reininger II Reininger III RI 1 132 Hz RII 1 113 Hz RIII 1 114 Hz RI 2 264 Hz RII 2...
Physiolaser olympic 500 Free programmable frequencies Select the free programable frequencies and change the frequency and the name by pressing the button “Edit”. Free Frequency display, 10 memories each providing 11 spaces for total 110 frequencies. After the specific numbers are selected the frequency can be used for therapy.
Physiolaser olympic 500 Diagnostic mode Insert the diagnosis probe/hand electrode into the socket on the front panel and press ON/OFF on the hand probe to activate the diagnostic mode. The diagnosis screen will appear. With the buttons ´Sensibility´ you can select the sensitivity at 3 levels (Llow, standard, high).
Page 34
Physiolaser olympic 500 Basic description of the diagnosis The Physiolaser olympic can be used for point search and diagnosis, including: search and measure body points, ear points, neural points If you detect a point, the display will show the point’s electrical value and an acoustic signal, increasing with the electrical conductance of the skin.
Physiolaser olympic 500 2. Skin environment, individuality The skin should be not too dry, too damp or callused. Each person’s skin is different; not everyone’s skin is equally suited to electronic search. Veterinary medicine Skin contact As animals are unable to hold hand electrodes, you must hold the electrode (or contact clamp) and then touch the animal at a furless spot (such as inside the ear) so that the circuit is complete for the diagnosis.
Physiolaser olympic 500 International plugs As an optional accessory you can use various interchangeable plugs corresponding to the international electric systems (Australia, USA, England, Europe). New installation of the software, update The front panel provides an opening for a memory card (SD format). By means of the RJ-memory card you can install the main software or update the device.
Physiolaser olympic 500 Applicators, optional Dental applicator with fiber optic (glass stainless steel) Nr. 5201, 70Ø 4 mm, bent tip (loss of power approx. 30%) Applicator convex Nr. 523 with lens Ø 10 mm (loss of power approx. 20%) Nr. 5231without lens Ø 4,5 mm...
Physiolaser olympic 500 Laser-protection goggles Both personnel and patients are to wear laser protection safety goggles during treatment sessions. The only types of safety goggles which may be worn are those which meet DIN 58215 standards. The filter glasses effective wavelength range include the laser light wavelength of the Physiolaser olympic equipment in use.
Physiolaser olympic 500 Electromagnetic compatibility - Warning instructions Precautionary measures There are special precautionary measures for medical electric devices as fare as electromagnetic compatibility is concerned. This device may be used only for the purpose described in the manual, set up and put into operation according to the notes for electromagnetic compatibility.
Page 40
Physiolaser olympic 500 Guidelines and manufacturer’s declaration – Electromagnetic immunity – for the laser device without life supporting function Immunity tests IEC 60601-test level Conformity level Electromagnetic ambient conditions - guidelines Portable and mobile radio sets must not be operated in...
Need help?
Do you have a question about the Physiolaser olympic 500 and is the answer not in the manual?
Questions and answers