Download Print this page

SG Electronics 2005 Series Operating Instructions Manual

Stanley x03 d-drivetm lock operating instructions

Advertisement

Quick Links

S&G
Z
®
The S&G
X
D-Drive
lock combines ease of operation with
©
03
security and flexibility. Its advanced electronic circuit design
makes it easy to open and easy to change codes. Follow these
instructions carefully to get the best possible use from your lock.
I
ntroductIon
• This S&G
X
D-Drive
©
03
multi-user mode with a factory master code of 1 2 3 4 5 6
#. This code can be used to open the lock and set or change
codes. You should set the lock to your own, unique master
code.
• Your lock can be programmed with a management reset code
that can be used to regain control of the lock in the event the
master code is lost. The management reset code must be
programmed into the lock before the master code is changed
for the first time.
• At your discretion, the lock can be set to accept a supervisor
code, up to seven different user codes, and a time delay
override code. The master code holder and the supervisor
code holder (if a supervisor code is set) are responsible
for maintaining the number of active users programmed into
each lock. The master code holder and the supervisor code
holder can create and delete user codes.
• The master code is designated as code #0. The supervisor
code (if set) is designated as code #1. The user codes (if
set) are designated by user position numbers 2, 3, 4, 5, 6, 7,
and 8. The time delay override code (if set) is designated as
code #9.
• Each time a button is pressed, the lock acknowledges it
by sounding a "beep," and the LED on the keypad will light
momentarily as the "beep" sounds. If it does not, check your
battery (or batteries) to make sure it is fresh and connected
properly, then try again.
• All codes must contain six digits or six letters. Any digit or
letter can be used as many times as you wish. For instance,
the following codes (while not recommended) will operate the
lock: 5 5 5 5 5 5 # OR J J J J J J #
Sargent & Greenleaf, Inc.
A Wholly Owned Subsidiary of Stanley Security Solutions, Inc.
PO Box 930, Nicholasville, Kentucky 40356 USA
Phone (859) 885-9411
Phone (800) 826-7652
FAX (859) 887-2057
FAX (800) 634-4843
© Copyright 2006, Sargent & Greenleaf
O
perating
D-Drive
Multi-User Electronic Safe Lock
03
lock is shipped from the factory in
i
nstructiOns
2005 Series
• All codes end with #. This signals the
lock that you have finished entering all
digits of the code.
• If you pause more than 10 seconds
between button presses when entering
a code, the lock will assume you do not
want to continue, and it will reset itself
to the original code. To open the lock,
begin the code entry sequence once again from the first step.
• If you realize you have pressed an incorrect button when
entering a code, press ✽ or simply pause ten seconds or more,
then begin entering your code again.
• If five incorrect codes are entered in a row, the S&G
Drive
lock will shut down for a period of ten minutes. This
is a security feature. Entering a code during this period will
result in two long error tones (braps). Pressing any buttons
during the lockout period will not affect the penalty timer.
After ten minutes, the lock should operate normally.
The lock can also go into the lockout period during
programming if it interprets an incorrect programming
sequence as five or more consecutive incorrect code entries.
If the lock emits two long error tones (braps) during repeated
programming attempts, it is in lockout mode. Wait ten
minutes, then try again.
• For UL installations, the maximum number of working codes
allowed is one.
• Personal data which can be directly related to a code holder,
such as a birthdate, should not be used in making up a lock
code. Avoid codes which can be easily guessed.
• After the lock is changed to a new code, the lock function
must checked by locking and unlocking it several times with
the container door open. Make sure it functions correctly
before closing the door.
Note: This lock has been Listed by Underwriters Laboratories for use with the following
S&G keypad(s): 6130-2XX and 6130-3XX
X
©
03
Sargent & Greenleaf S.A.
9, chemin du Croset
1024 Ecublens, Switzerland
Phone +41-21 694 34 00
FAX +41-21 694 34 09
Document 630-735
Revised 7/25/06
D-

Advertisement

loading

Summary of Contents for SG Electronics 2005 Series

  • Page 1 (while not recommended) will operate the lock: 5 5 5 5 5 5 # OR J J J J J J # Sargent & Greenleaf, Inc. A Wholly Owned Subsidiary of Stanley Security Solutions, Inc. PO Box 930, Nicholasville, Kentucky 40356 USA Phone (859) 885-9411...
  • Page 2 Multi-User Electronic Safe Lock ™ 2005 Series 2. If the lock “chirps” when keys are pressed, but it will not open, the batteries may be drained to the point that they will not operate the lock’s solenoid. Follow the battery replacement procedure in this manual.
  • Page 3: O Pening The L Ock

    Multi-User Electronic Safe Lock ™ 2005 Series the time delay, for the opening code at the end of the time delay, or for both codes. The silent alarm signal will be sent each time a duress code is entered.
  • Page 4 Multi-User Electronic Safe Lock ™ 2005 Series ➥ hangIng Any code holder can change his own code. The process is: 2 2 ✽ OLD CODE # For example, changing a user code of 2 2 2 2 2 2 to a new code of 2 4 6 8 3 3 would be accomplished as follows: 2 2 ✽...
  • Page 5 © Copyright 2006, Sargent & Greenleaf perating nstructiOns Multi-User Electronic Safe Lock ™ 2005 Series ➥ hangIng the The length of the opening window period is set as follows. The period can be anywhere from 1 to 10 minutes. ➥...
  • Page 6 Multi-User Electronic Safe Lock ™ 2005 Series After this programming procedure is completed, the lock will be disabled. If a valid code is entered, the lock will emit a double beep, but will not open. ♪ ♪ ♪ ♪ ♪...
  • Page 7 © Copyright 2006, Sargent & Greenleaf perating nstructiOns Multi-User Electronic Safe Lock ™ 2005 Series anagIng mpLoyee ccess ➥ Your lock must have been ordered with this option. Using the audit ♪ ♪ ♪...
  • Page 8: Battery Condition

    Set and use the management reset code (MRC) perating nstructiOns Multi-User Electronic Safe Lock ™ 2005 Series The S&G recommend Duracell be replaced, twenty consecutive beeps will be heard after the last number of the code and # have been pressed. The battery will have to be replaced before the lock can be opened.
  • Page 9 Align the battery and connector terminals, and snap the battery to the connector (Figure 3). © Copyright 2006, Sargent & Greenleaf attery hanging Multi-User Electronic Safe Lock ™ 2005 Series brand. ® brand alkaline ® Page 9 nstructiOns Figure 1...
  • Page 10 Check your lock operation at least three times with the container door open before closing it. attery hanging Multi-User Electronic Safe Lock ™ 2005 Series Page 10 nstructiOns Figure 4 Figure 5 Figure 6 © Copyright 2006, Sargent & Greenleaf...
  • Page 12 TO BE IMPERVIOUS TO FORCIBLE OR SURREPTITIOUS ENTRY, AND SELLER SHALL HAVE NO LIABILITY FOR DAMAGE TO OR LOSS OF PROPERTY SOUGHT TO BE PROTECTED BY ANY SUCH LOCK. Sargent & Greenleaf, Inc. Sargent & Greenleaf S.A. A Wholly Owned Subsidiary of Stanley Security Solutions, Inc. 9, chemin du Croset PO Box 930, Nicholasville, Kentucky 40356 USA 1024 Ecublens, Switzerland...

This manual is also suitable for:

Z03 d-drive 2005 series