Onan DYC Series Operator's Manual And Parts Catalog page 9

Electric generating sets
Table of Contents

Advertisement

TABLE 1B
GENERATOR VOLTAGE/CURRENT OPTIONS
100 kW
80 kW
125 kVA 60 Hz
100 kVA 50 Hz
D O U B L E
S E R I E S
P A R A L L E L
S E R I E S
R E F V O L T A G E
V O L T S
F R E Q
P H A S E
A M P E R E S
D E L T A
D E L T A
W Y E
WYE
WIRE (W12) T A P
110/220
50 Hz
1
455
X
-
H6
115/230
50 Hz
1
435
X
H6
120/240
60 Hz
1
521
X
H5
110/190
50 Hz
3
304
.
X
H3
115/200
50 Hz
3
289
X
H4
120/208
50 Hz
3
278
X
H4
120/208
60 Hz
3
347
X
H3
110/220
50 Hz
3
262
X
H6
127/220
50 Hz
3
262
X
H5
127/220
60 Hz
3
328
X
H4
115/230
50 Hz
3
251
X
H6
120/240
60 Hz
3
301
X
H5
139/240
60 Hz
3
301
X
H5
220/380
50 Hz
3
152
X
H3
230/400
50 Hz
3
144
X
H4
240/416
50 Hz
3
139
X
H4
240/416
60 Hz
3
173
X
H3
254/440
50 Hz
3
131
X
H5
254/440
60 Hz
3
164
X
H4
277/480
60 Hz
3
150
X
H5
9X
H5—Not
347/600
60 Hz
3
120
Reconnectible
Single phase current value is available only from special long-stack unit
(option B125). A standard 3-phase generator connected into a Double Delta
single phase configuration will deliver 2/3 current value shown
(i.e. 455 x .667 = 303 amperes)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents