User Information Manual Models B85, B120 & B160 Condensing ASME Boiler WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury or death. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of t his or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance.
Glow Brand C95 & C140 Table of Contents SAFETY CONSIDERATIONS CONTROLS OPERATING AND SERVICE DISPLAY CODE BOILER OPERATION BOILER DOMESTIC HOT WATER MODES LIGHTING & SHUTTING DOWN THE BOILER MAINTENANCE SERVICE RECORDS...
Glow Brand B85, B120 & B160 General Safety Warnings SAFETY CONSIDERATIONS WARNING Installation, start-up and servicing of GLOW boilers must be done with due care If the information in this and attention, and should only be performed by competent, qualified, licensed manual is not followed exactly, and trained heating technicians. Failure to read and comply with all instructions...
Page 4
Glow Brand B85, B120 & B160 User Information Manual User Information Manual DANGER The temperature at which injury occurs varies with the person's age and time of exposure. Water temperature over 125°F/52°C can cause severe burns instantly or death from scalding.
Page 5
Glow Brand B85, B120 & B160 General Safety Warnings WARNING HOT WATER CAN SCALD! Water Temperatures over 125°F / 52°C can cause severe burns instantly or death from scalds. Children, disabled, and elderly are at highest risk of being scalded. • Never leave then unattended in or near the shower, bathtub or sink.
Page 6
Glow Brand B85, B120 & B160 User Information Manual User Information Manual WARNING Should overheating occur or the gas supply fails to shut off, do not turn off or disconnect the electrical supply to the pump. Instead shut off the gas supply at a...
Glow Brand B85, B120 & B160 Controls CONTROLS CAUTION Before adjusting the control settings, read the control instructions carefully BAR PSI OUTSIDE RESET ENTER Function Description CH Λ Increase the CH set-point CH V Decrease the CH set-point DHW Λ Increase the DHW set-point DHW V Decrease the DHW set-point RESET/ENTER Status overview: Enter the main menu or reset a lockout error by pressing the button for at least 2 seconds.
Page 8
Glow Brand B85, B120 & B160 User Information Manual USER SETTINGS MENU (0.000) In the User Settings Menu the user can change the basic settings of the appliance according to their preference. From the Main Screen press the RESET/ENTER button on the console to gain access to the Main Menu Screen (Fig.1). Pressing RESET/ENTER again will grant, access to the User Menu.
Glow Brand B85, B120 & B160 Controls OPERATING AND SERVICE DISPLAY CODE Power-up When the display powers up it will attempt to communicate with the main control and retrieve the required data. During this process the ‘init’ message is displayed on the screen. When all data was successfully retrieved, the Status overview is displayed.
Page 10
Glow Brand B85, B120 & B160 User Information Manual Error / Warning present When an error or warning is present, the small digit section will show one of the following error types: • Lockout (Loc) • Blocking (Err) • Warning (AttE) The large digit section will show the error number.
Glow Brand B85, B120 & B160 Controls Additionally CH and/or DHW operation can be disabled by selecting the ‘OFF’ option. To re-enable CH and/or DHW operation, simply select a set point. The value is automatically stored when editing the set point is exited. This can be after 5 seconds of no (button) activity, when the user presses Enter to confirm the value, or when switching to another quick set point.
Glow Brand B85, B120 & B160 User Information Manual a. Primary Circulating Pump - Circulates water through the boiler. This pump is hydraulically separated from the CH pump by closely spaced tees or a primary loop. The primary pump is always operating when the system is responding to a call for CH and or DHW.
Glow Brand B85, B120 & B160 User Information Manual User Information Manual MAINTENANCE Daily Maintenance WARNING • Check the surrounding area – inspect for water leaks in the general area CRYSTALLINE SILICA: around the boiler and boiler piping certain components confined • Check the system pressure. The heating system pressure should not exceed in the combustion chamber 25psi and not drop below 10psi in most applications.
Page 15
Glow Brand B85, B120 & B160 Maintenance Relief Valve - Maintenance and Testing WARNING The relief valve manufacturer requires that under normal operating conditions Do not use automotive-type a “try lever test” must be performed every two months. Under severe service ethylene or other types of conditions, or if corrosion and/or deposits are noticed within the valve body, automotive glycol antifreeze, or testing must be performed more often.
Glow Brand B85, B120 & B160 User Information Manual User Information Manual SERVICE RECORDS DATE LICENSED CONTRACTOR DESCRIPTION OF WORK DONE...
Page 18
When you contact Technical Support, please have the following information at hand. 1. Model Number 2. Serial Number 3. Date Purchased 4. Installation location and type 5. Error code, if any appears on the front display. GLOW BRAND 209 Citation Drive Concord, ON L4K 2Y8 Tel: 905-669-7373 Fax. 905-264-1147 Email: info@glowbrand.ca...